Literature DB >> 16700025

Velocity-selective arterial spin labeling.

Eric C Wong1, Matthew Cronin, Wen-Chau Wu, Ben Inglis, Lawrence R Frank, Thomas T Liu.   

Abstract

In pathologies in which slow or collateral flow conditions may exist, conventional arterial spin labeling (ASL) methods that apply magnetic tags based on the location of arterial spins may not provide robust measures of cerebral blood flow (CBF), as the transit delay for the delivery of blood to target tissues may far exceed the relaxation time of the tag. Here we describe current methods for ASL with velocity-selective (VS) tags (termed VSASL) that do not require spatial selectivity and can thus provide quantitative measures of CBF under slow and collateral flow conditions. The implementation of a robust multislice VSASL technique is described in detail, and data obtained with this technique are compared with those obtained with conventional pulsed ASL (PASL). The technical considerations described here include the design of VS pulses, background suppression, anisotropy with respect to velocity-encoding directions, and CBF quantitation issues. Copyright 2006 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2006        PMID: 16700025     DOI: 10.1002/mrm.20906

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  100 in total

1.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

2.  CBF measurements using multidelay pseudocontinuous and velocity-selective arterial spin labeling in patients with long arterial transit delays: comparison with xenon CT CBF.

Authors:  Deqiang Qiu; Matus Straka; Zungho Zun; Roland Bammer; Michael E Moseley; Greg Zaharchuk
Journal:  J Magn Reson Imaging       Date:  2012-02-22       Impact factor: 4.813

Review 3.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

4.  Arterial spin labeling in neuroimaging.

Authors:  Sasitorn Petcharunpaisan; Joana Ramalho; Mauricio Castillo
Journal:  World J Radiol       Date:  2010-10-28

5.  Brain MR perfusion-weighted imaging with alternate ascending/descending directional navigation.

Authors:  Sung-Hong Park; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2010-09-21       Impact factor: 4.668

6.  Comparison of arterial spin labeling and bolus perfusion-weighted imaging for detecting mismatch in acute stroke.

Authors:  Greg Zaharchuk; Ibraheem S El Mogy; Nancy J Fischbein; Gregory W Albers
Journal:  Stroke       Date:  2012-04-26       Impact factor: 7.914

7.  Arterial spin labeling for acute stroke: practical considerations.

Authors:  Greg Zaharchuk
Journal:  Transl Stroke Res       Date:  2012-04-14       Impact factor: 6.829

Review 8.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

9.  In vivo magnetic resonance imaging and spectroscopy. Technological advances and opportunities for applications continue to abound.

Authors:  Peter van Zijl; Linda Knutsson
Journal:  J Magn Reson       Date:  2019-07-09       Impact factor: 2.229

10.  Perfusion of the placenta assessed using arterial spin labeling and ferumoxytol dynamic contrast enhanced magnetic resonance imaging in the rhesus macaque.

Authors:  Kai D Ludwig; Sean B Fain; Sydney M Nguyen; Thaddeus G Golos; Scott B Reeder; Ian M Bird; Dinesh M Shah; Oliver E Wieben; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2018-10-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.