Literature DB >> 21387447

B0 field inhomogeneity considerations in pseudo-continuous arterial spin labeling (pCASL): effects on tagging efficiency and correction strategy.

Hesamoddin Jahanian1, Douglas C Noll, Luis Hernandez-Garcia.   

Abstract

Pseudo-continuous arterial spin labeling (pCASL) is a very powerful technique to measure cerebral perfusion, which circumvents the problems affecting other continuous arterial spin labeling schemes, such as magnetization transfer and duty cycle. However, some variability in the tagging efficiency of the pCASL technique has been reported. This article investigates the effect of B(0) field inhomogeneity on the tagging efficiency of the pCASL pulse sequence as a possible cause of this variability. Both theory and simulated data predict that the efficiency of pseudo-continuous labeling pulses can be degraded in the presence of off-resonance effects. These findings are corroborated by human in vivo measurements of tagging efficiency. On the basis of this theoretical framework, a method utilizing B(0) field map information is proposed to correct for the possible loss in tagging efficiency of the pCASL pulse sequence. The efficiency of the proposed correction method is evaluated using numerical simulations and in vivo implementation. The data show that the proposed method can effectively recover the lost tagging efficiency and signal-to-noise ratio of pCASL caused by off-resonance effects.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21387447     DOI: 10.1002/nbm.1675

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  34 in total

1.  Blind detection of vascular sources and territories using random vessel encoded arterial spin labeling.

Authors:  Eric C Wong; Jia Guo
Journal:  MAGMA       Date:  2012-01-10       Impact factor: 2.310

2.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

3.  Pulsed arterial spin labelling at ultra-high field with a B 1 (+) -optimised adiabatic labelling pulse.

Authors:  Fabian Zimmer; Kieran O'Brien; Steffen Bollmann; Josef Pfeuffer; Keith Heberlein; Markus Barth
Journal:  MAGMA       Date:  2016-04-15       Impact factor: 2.310

Review 4.  Comparison of cerebral blood flow measurement with [15O]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review.

Authors:  Audrey P Fan; Hesamoddin Jahanian; Samantha J Holdsworth; Greg Zaharchuk
Journal:  J Cereb Blood Flow Metab       Date:  2016-03-04       Impact factor: 6.200

5.  Cardiac-triggered pseudo-continuous arterial-spin-labeling: A cost-effective scheme to further enhance the reliability of arterial-spin-labeling MRI.

Authors:  Yang Li; Deng Mao; Zhiqiang Li; Michael Schär; Jay J Pillai; James G Pipe; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2018-01-25       Impact factor: 4.668

Review 6.  Arterial spin-labeled perfusion imaging in acute ischemic stroke.

Authors:  Greg Zaharchuk
Journal:  Stroke       Date:  2014-03-06       Impact factor: 7.914

7.  Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys.

Authors:  Hao Song; Dan Ruan; Wenyang Liu; V Andrew Stenger; Rolf Pohmann; Maria A Fernández-Seara; Tejas Nair; Sungkyu Jung; Jingqin Luo; Yuichi Motai; Jingfei Ma; John D Hazle; H Michael Gach
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

Review 8.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

9.  Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition.

Authors:  Dapeng Liu; Feng Xu; Wenbo Li; Peter C van Zijl; Doris D Lin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-05-13       Impact factor: 4.668

10.  Pseudo continuous arterial spin labeling quantification in anemic subjects with hyperemic cerebral blood flow.

Authors:  Adam Bush; Yaqiong Chai; So Young Choi; Lena Vaclavu; Scott Holland; Aart Nederveen; Thomas Coates; John Wood
Journal:  Magn Reson Imaging       Date:  2017-12-09       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.