| Literature DB >> 27747239 |
Mieszko Wieckiewicz1, Natalia Grychowska2, Marek Zietek3, Wlodzimierz Wieckiewicz2.
Abstract
Background. Addition silicones are popular as dental impression materials and are used in bite registration procedures. Objective. This study aimed to compare the postsetting elasticities and other mechanical properties of thirteen addition silicone interocclusal recording materials. Materials and Methods. The following materials were investigated: Colorbite D, Futar D, Genie Bite, Jet Blue Bite fast, Memoreg 2, O-Bite, Occlufast Rock, Omni-Bite Plus, Regidur i, Registrado X-tra, Regofix transparent, StoneBite, and Variotime Bite. Thirty specimens of each material were tested. The elasticities and strengths of the materials were measured with a universal testing machine, and computer software was used to determine the E-moduli, ultimate tensile strengths, and ultimate elongations of the specimens. Results. The results were subjected to statistical analysis using the Kruskal-Wallis test (p ≤ 0.05). The statistics revealed that the mean E-modulus values varied significantly across the materials (p = 0.000) and were highest for the StoneBite and Registrado X-tra and lowest for the Regofix transparent. The ultimate tensile strengths were highest for the Regofix transparent and Registrado X-tra (p = 0.000) and lowest for the Jet Blue Bite fast and Memoreg 2 (p = 0.000). The elongation percentages at the point of breaking varied significantly across the materials (p = 0.000); the lowest value was observed for the StoneBite, whereas the Regofix transparent nearly doubled original length. Conclusions. The authors concluded that materials with the high E-moduli and great ultimate tensile strengths may be most useful clinically. Registrado X-tra and StoneBite best met these criteria.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27747239 PMCID: PMC5056310 DOI: 10.1155/2016/7456046
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Interocclusal recording materials included in the study.
| Material | Lot number | Manufacturer |
|---|---|---|
| Colorbite D | 148137 | Zhermack, BadiaPolesine, Italy |
| Futar D | 112151 | Kettenbach GmbH & Co. KG., Eschenburg, Germany |
| Genie Bite | 110826 | Sultan Healthcare, York, PA, USA |
| Jet Blue Bite fast | C30559 | Coltène/Whaledent AG, Altstätten, Switzerland |
| Memoreg 2 | 380036 | Heraeus Kulzer GmbH, Hanau, Germany |
| O-Bite | 683563 | DMG Chemisch-Pharmazeutische Fabrik GmbH, Hamburg, Germany |
| Occlufast Rock | 132241 | Zhermack, BadiaPolesine, Italy |
| Omni-Bite Plus | 20242 | Omnident-Dental-Handels GmbH, Rodgau, Germany |
| Regidur i | 203743/2912 | Bielefelder Dentalsilicone GmbH & Co. KG, Bielefeld, Germany |
| Registrado X-tra | 1229190 | VOCO GmbH, Cuxhaven, Germany |
| Regofix transparent | 207001.09 | Dreve Dentamid GmbH, Unna, Germany |
| StoneBite | 208132.10 | Dreve Dentamid GmbH, Unna, Germany |
| Variotime Bite | 380076 | Heraeus Kulzer GmbH, Hanau, Germany |
Comparison of E-modulus mean values for the tested materials.
| Material |
|
|---|---|
| (1) StoneBite | 167.19 ± 19.59(1) |
| (2) Registrado X-tra | 107.38 ± 11.36(1) |
| (3) O-Bite | 93.94 ± 13.32(2) |
| (4) Variotime Bite | 83.59 ± 8.76(3) |
| (5) Futar D | 64.85 ± 9.05(4) |
| (6) Colorbite D | 57.38 ± 7.52(5) |
| (7) Genie Bite | 55.47 ± 7.27(6) |
| (8) Occlufast Rock | 48.41 ± 7.38(6) |
| (9) Regidur i | 48.11 ± 10.47(6) |
| (10) Omni-Bite Plus | 47.88 ± 12.07(6) |
| (11) Jet Blue Bite fast | 43.34 ± 9.66(7) |
| (12) Memoreg 2 | 42.22 ± 6.87(7) |
| (13) Regofix transparent | 6.53 ± 2.34(8) |
(1) p < 0.05 in comparison to (5)–(13).
(2) p < 0.05 in comparison to (6)–(13).
(3) p < 0.05 in comparison to (7)–(13).
(4) p < 0.05 in comparison to (1), (2) and (11)–(13).
(5) p < 0.05 in comparison to (1)–(3) and (13).
(6) p < 0.05 in comparison to (1)–(4) and (13).
(7) p < 0.05 in comparison to (1)–(5).
(8) p < 0.05 in comparison to (1)–(10).
Comparison of ultimate tensile strength mean values for the tested materials.
| Material | Ultimate tensile strength [MPa] |
|---|---|
| (1) Regofix transparent | 5.67 ± 1.06(1) |
| (2) Registrado X-tra | 5.53 ± 1.13(1) |
|
| |
| (3) Omni-Bite Plus | 4.67 ± 0.87(2) |
| (4) Colorbite D | 4.43 ± 0.83(2) |
| (5) StoneBite | 4.37 ± 0.62(2) |
|
| |
| (6) Occlufast Rock | 4.18 ± 0.63(3) |
| (7) O-Bite | 4.08 ± 0.80(3) |
| (8) Variotime Bite | 4.07 ± 0.69(3) |
| (9) Genie Bite | 3.92 ± 0.52(3) |
|
| |
| (10) Regidur i | 3.47 ± 0.51(4) |
| (11) Futar D | 3.45 ± 0.60(4) |
|
| |
| (12) Jet Blue Bite fast | 2.95 ± 0.57(5) |
| (13) Memoreg 2 | 2.67 ± 0.47(5) |
(1) p < 0.05 in comparison to (6)–(13).
(2) p < 0.05 in comparison to (10)–(13).
(3) p < 0.05 in comparison to (1), (2) and (12), (13).
(4) p < 0.05 in comparison to (1)–(5).
(5) p < 0.05 in comparison to (1)–(9).
Comparison of percentage ultimate elongation mean values for the tested materials.
| Material | Ultimate elongation [%] |
|
| |
| (1) Regofix transparent | 95.97 ± 19.42(1) |
| (2) Omni-Bite Plus | 14.58 ± 1.34(2) |
| (3) Occlufast Rock | 12.78 ± 1.40(3) |
| (4) Regidur i | 12.56 ± 1.12(3) |
| (5) Colorbite D | 11.01 ± 1.28(4) |
| (6) Memoreg 2 | 9.66 ± 1.25(5) |
| (7) Genie Bite | 9.65 ± 1.27(5) |
| (8) Jet Blue Bite fast | 8.93 ± 1.15(6) |
| (9) Futar D | 8.43 ± 1.08(7) |
| (10) Registrado X-tra | 7.12 ± 1.01(8) |
| (11) Variotime Bite | 6.36 ± 0.64(9) |
| (12) O-Bite | 5.81 ± 0.61(10) |
| (13) StoneBite | 3.69 ± 0.53(11) |
(1) p < 0.05 in comparison to (5)–(13).
(2) p < 0.05 in comparison to (6)–(13).
(3) p < 0.05 in comparison to (8)–(13).
(4) p < 0.05 in comparison to (1) and (10)–(13).
(5) p < 0.05 in comparison to (1)-(2) and (11)–(13).
(6) p < 0.05 in comparison to (1)–(4) and (12)-(13).
(7) p < 0.05 in comparison to (1)–(4) and (13).
(8) p < 0.05 in comparison to (1)–(5).
(9) p < 0.05 in comparison to (1)–(7).
(10) p < 0.05 in comparison to (1)–(8).
(11) p < 0.05 in comparison to (1)–(9).
Figure 1The stress-strain curves, showing the relations between achieved mean values of ultimate tensile strengths [MPa] and ultimate elongations [%] for the tested materials.