Evaluation of Four Elastomeric Interocclusal Recording Materials.

P Dua1, S H Gupta2, S Ramachandran3, H S Sandhu4.   

Abstract

BACKGROUND: The fabrication of dental prosthesis requires the transfer of interocclusal records from patient's mouth to semi-adjustable articulators using different kinds of recording media. Any inaccuracy in these interocclusal records leads to occlusal errors in the final prosthesis. This study was conducted to evaluate the dimensional changes occurring in the interocclusal recording material over a given period of time and the material's resistance to compression during the cast mounting on the articulator.
METHODS: In this in vitro study, the linear dimensional change and compressive resistance of four commercially available elastomeric interocclusal recording media was tested. Three were addition silicones and the fourth was a polyether material. Cylindrical samples of 10mm diameter of each material were prepared in three different thicknesses of 2, 4 and 6mm. Ten samples each of thickness of 2, 4 and 6mm for all four materials were prepared (total of 120 samples). The linear dimensional changes of the samples were evaluated after 24 hours of fabrication. The compressive resistance was measured when each of these was subjected to a constant compressive load of 25 Newtons.
RESULTS: The mean linear dimensional change in a horizontal plane was minimum for Kanibite Hard, an addition silicone. Ramitec showed the maximum linear dimensional change. The mean compression distance was least for Futar D Occlusion (an addition silicone) and maximum for Ramitec (a polyether). It was observed that the samples of thickness 2mm for all the materials underwent least compression.
CONCLUSION: The compressive resistance of each elastomer was inversely proportional to the thickness of the sample. This implies that minimum thickness of the recording materials should be used for recording maxillomandibular relations without sacrificing the strength of the interocclusal record.

Entities:  

Keywords:  Articulation; Compressive resistance; Interocclusal records; Linear dimensional change; Occlusion

Year:  2011        PMID: 27408006      PMCID: PMC4922742          DOI: 10.1016/S0377-1237(07)80143-2

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  12 in total

Review 1.  Overview of articulation materials and methods for the prosthodontic patient.

Authors:  D L Dixon
Journal:  J Prosthet Dent       Date:  2000-02       Impact factor: 3.426

Review 2.  Recording the retruded contact position: a review of clinical techniques.

Authors:  P H R Wilson; A Banerjee
Journal:  Br Dent J       Date:  2004-04-10       Impact factor: 1.626

Review 3.  Principles for selecting interocclusal records for articulation of dentate and partially dentate casts.

Authors:  M A Freilich; J V Altieri; J J Wahle
Journal:  J Prosthet Dent       Date:  1992-08       Impact factor: 3.426

4.  Differential accuracy of silicone-body interocclusal records and associated weight loss due to volatiles.

Authors:  P L Millstein; R E Clark; R L Myerson
Journal:  J Prosthet Dent       Date:  1975-06       Impact factor: 3.426

5.  Factors influencing centric relation records in edentulous mouths. 1964.

Authors:  A Albert Yurkstas; Krishan K Kapur
Journal:  J Prosthet Dent       Date:  2005-04       Impact factor: 3.426

6.  An experimental study on the influence of the derived casts on the accuracy of different recording materials. Part I: Plaster, impression compound, and wax.

Authors:  J Müller; G Götz; W Hörz; E Kraft
Journal:  J Prosthet Dent       Date:  1990-03       Impact factor: 3.426

7.  Evaluation of the accuracy of interocclusal records in relation to two recording techniques.

Authors:  A P Tripodakis; V K Vergos; A G Tsoutsos
Journal:  J Prosthet Dent       Date:  1997-02       Impact factor: 3.426

8.  Comparison of five interocclusal recording materials.

Authors:  V Lassila
Journal:  J Prosthet Dent       Date:  1986-02       Impact factor: 3.426

9.  Accuracy of three interocclusal recording materials used to mount a working cast.

Authors:  L C Breeding; D L Dixon; K E Kinderknecht
Journal:  J Prosthet Dent       Date:  1994-03       Impact factor: 3.426

10.  Clinical evaluation of the accuracy of interocclusal recording materials.

Authors:  L Fattore; W F Malone; J L Sandrik; B Mazur; T Hart
Journal:  J Prosthet Dent       Date:  1984-02       Impact factor: 3.426

View more
  2 in total

1.  Hybrid tracer - A modified novel extra oral tracer.

Authors:  Nithin Kumar Sonnahalli; Prajna P Shetty; Ramesh Chowdhary
Journal:  J Oral Biol Craniofac Res       Date:  2022-09-26

2.  Evaluation of the Elastic Properties of Thirteen Silicone Interocclusal Recording Materials.

Authors:  Mieszko Wieckiewicz; Natalia Grychowska; Marek Zietek; Wlodzimierz Wieckiewicz
Journal:  Biomed Res Int       Date:  2016-09-26       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.