An experimental study on particular physical properties of several interocclusal recording media. Part II: Linear dimensional change and accompanying weight change.

Konstantinos X Michalakis1, Argiris Pissiotis, Vassiliki Anastasiadou, Danai Kapari.   

Abstract

PURPOSE: The purpose of this study was to evaluate the linear dimensional change and accompanying weight change of several elastomeric interocclusal recording media.
MATERIALS AND METHODS: Ten 50 mm long, 8 mm wide, 3 mm deep Teflon molds and a stainless steel die were constructed for the purposes of this study. The die was made in order to produce standardized reference lines, which were used for the measurement of the linear change. After homogeneous mixing, each material was carried from the mixing pad or directly from the mixing tip to the Teflon mold. The mold was inverted onto the stainless steel die. The materials were allowed to set for the manufacturers' suggested setting time plus an additional 3 minutes to ensure polymerization of the material. An electronic scale (Galaxy 110, Ohaus, Pine Brook, NJ) was used for the measurement of the weight change of the specimens and a traveling micrometer microscope (Griffin Ltd., London, England) was used to measure the linear changes at 5 time intervals: 0, 1 hour, 24, 48, and 72 hours.
RESULTS: Analysis of variance for a significance level of 5% revealed that there was a statistically significant effect of the "material" factor on the weight changes (F= 2,229.98, p < 0.0005). There was also a statistically significant effect of the "time" factor on the weight changes (F= 2,332.04, p < 0.0005). Descriptive statistics and Tukey's Honest Significant Difference Test revealed that the elastomeric material with the greatest weight changes is polyether (Ramitec). Analysis of variance for a significance level of 5% revealed that there is a statistically significant effect of the "material" factor on the linear changes (F= 215.54, p < 0.0005). There is also a statistically significant effect of the "time" factor on the linear changes (F= 1,996.01, p < 0.0005). Descriptive statistics and Tukey's Honest Significant Difference test revealed that the elastomeric material with the smallest linear changes is polyether (Ramitec).
CONCLUSIONS: Of all materials tested, Ramitec (polyether) presented the smallest linear change at all time intervals. Addition reaction silicones presented statistically significant differences in recordings of linear changes among them only at the 1st and the 24th hour. Linear changes did not seem to be associated with weight changes.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15345014     DOI: 10.1111/j.1532-849X.2004.04024.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  7 in total

1.  Evaluation of dimensional stability, accuracy and surface hardness of interocclusal recording materials at various time intervals: an in vitro study.

Authors:  G Anup; S C Ahila; M Vasanthakumar
Journal:  J Indian Prosthodont Soc       Date:  2011-03-06

2.  A Comparative Study to Evaluate the Compression Resistance of Different Interocclusal Recording Materials: An In Vitro Study.

Authors:  Rahul Nagrath; Manesh Lahori; Varun Kumar; Varun Gupta
Journal:  J Indian Prosthodont Soc       Date:  2014-07-17

3.  Data on dental bite materials with stability and displacement under load.

Authors:  Harsh Kasabwala; Subhabrata Maiti; V Ashok; Keerthi Sashank
Journal:  Bioinformation       Date:  2020-12-31

4.  A comparative evaluation of three dimensional accuracy of different types of interocclusal recording materials - an in vitro study.

Authors:  Aparna Dwivedi; Kavita Maru; Aakash Sharma
Journal:  Med Pharm Rep       Date:  2020-07-22

5.  Accuracy of several implant bite registration techniques: an in-vitro pilot study.

Authors:  Do-Hyun Park; Ji-Man Park; Jae-Won Choi; Eun-Sook Kang; Eun-Bin Bae; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

6.  Evaluation of the Elastic Properties of Thirteen Silicone Interocclusal Recording Materials.

Authors:  Mieszko Wieckiewicz; Natalia Grychowska; Marek Zietek; Wlodzimierz Wieckiewicz
Journal:  Biomed Res Int       Date:  2016-09-26       Impact factor: 3.411

7.  A comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in-vitro multi-centre study.

Authors:  Sampath Kumar Tejo; Anil G Kumar; Vivekanand S Kattimani; Priti D Desai; Sandeep Nalla; Krishna Chaitanya K
Journal:  Head Face Med       Date:  2012-10-05       Impact factor: 2.151

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.