Literature DB >> 11203625

Materials for interocclusal records and their ability to reproduce a 3-dimensional jaw relationship.

G Ockert-Eriksson1, A Eriksson, P Lockowandt, O Eriksson.   

Abstract

PURPOSE: The purpose of this study was to determine if accuracy and dimensional stability of vinyl polysiloxanes and irreversible hydrocolloids stabilized by a tray used for fixed prosthodontics, removable partial, and complete denture cases are comparable to those of waxes and record rims and if storage time (24 hours or 6 days) affects dimensional stability of the tested materials.
MATERIALS AND METHODS: Two waxes, two record rims, three vinyl polysiloxanes, and one irreversible hydrocolloid (alginate) were examined. Three pairs of master casts with measuring steel rods were mounted on an articulator (initial position). Five records were made of each material, and the upper cast was remounted after 24 hours or 6 days so that deviations from the initial position could be measured.
RESULTS: Vinyl polysiloxanes reinforced by a stabilization tray were the most accurate materials able to reproduce a settled interocclusal position. Mounting casts (fixed prosthodontics cases) without records gave accuracy similar to wax records. Record rims used for removable partial and complete denture cases produced lesser accuracy than vinyl polysiloxanes and irreversible hydrocolloid stabilized by a tray. Accuracy was not significantly affected by storage time.
CONCLUSION: The results show that accuracy of vinyl polysiloxanes and irreversible hydrocolloids reinforced by a tray is superior to that of record rims with regard to the complete denture case and is among the most accurate with regard to the removable partial denture case. For fixed prosthodontics, however, reinforcement is unnecessary.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11203625

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

1.  Data on dental bite materials with stability and displacement under load.

Authors:  Harsh Kasabwala; Subhabrata Maiti; V Ashok; Keerthi Sashank
Journal:  Bioinformation       Date:  2020-12-31

2.  Evaluation and comparison of resistance to compression of various interocclusal recording media: an in vitro study.

Authors:  G S Chandu; Mohd Faisal Khan; S K Mishra; Pooja Asnani
Journal:  J Int Oral Health       Date:  2015-05

3.  Accuracy of several implant bite registration techniques: an in-vitro pilot study.

Authors:  Do-Hyun Park; Ji-Man Park; Jae-Won Choi; Eun-Sook Kang; Eun-Bin Bae; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

4.  Evaluation of the Elastic Properties of Thirteen Silicone Interocclusal Recording Materials.

Authors:  Mieszko Wieckiewicz; Natalia Grychowska; Marek Zietek; Wlodzimierz Wieckiewicz
Journal:  Biomed Res Int       Date:  2016-09-26       Impact factor: 3.411

5.  A comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in-vitro multi-centre study.

Authors:  Sampath Kumar Tejo; Anil G Kumar; Vivekanand S Kattimani; Priti D Desai; Sandeep Nalla; Krishna Chaitanya K
Journal:  Head Face Med       Date:  2012-10-05       Impact factor: 2.151

6.  Trends in Selection, Usage, and Techniques of Interocclusal Record Materials among Private Dental Practitioners: A Survey.

Authors:  Kavita Maru; Aparna Dwivedi; Jatin Agarwal; Anup Vyas; Sumeet Jain; Poonam Kulkarni
Journal:  Contemp Clin Dent       Date:  2018-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.