Literature DB >> 22379302

Evaluation of dimensional stability, accuracy and surface hardness of interocclusal recording materials at various time intervals: an in vitro study.

G Anup, S C Ahila, M Vasanthakumar.   

Abstract

To evaluate and compare the dimensional stability, accuracy and surface hardness of three interocclusal recording materials at various time intervals. Polyvinylsiloxane, Zinc oxide eugenol, Aluwax were taken for this study. A stainless steel die of ADA specification no 19. was prepared. A total of ten samples were made with each group. The samples were measured using a travelling microscope of 10× magnification at 1, 24, 48 and 72 h time intervals. Five readings were taken for each sample, the mean was considered to measure the dimensional change, accuracy and surface hardness. The values obtained were statistically analysed by ANOVA and Tukey HSD-Honestly significant difference. Polyvinylsiloxane was the most dimensionally stable, accurate and had the highest surface hardness among the three inter-occlusal materials.

Entities:  

Keywords:  Accuracy; Dimensional stability; Hardness

Year:  2011        PMID: 22379302      PMCID: PMC3095739          DOI: 10.1007/s13191-011-0054-0

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  11 in total

1.  An experimental study on particular physical properties of several interocclusal recording media. Part II: Linear dimensional change and accompanying weight change.

Authors:  Konstantinos X Michalakis; Argiris Pissiotis; Vassiliki Anastasiadou; Danai Kapari
Journal:  J Prosthodont       Date:  2004-09       Impact factor: 2.752

Review 2.  Principles for selecting interocclusal records for articulation of dentate and partially dentate casts.

Authors:  M A Freilich; J V Altieri; J J Wahle
Journal:  J Prosthet Dent       Date:  1992-08       Impact factor: 3.426

3.  Differential accuracy of silicone-body interocclusal records and associated weight loss due to volatiles.

Authors:  P L Millstein; R E Clark; R L Myerson
Journal:  J Prosthet Dent       Date:  1975-06       Impact factor: 3.426

4.  Mounting casts on an articulator using interocclusal records.

Authors:  Muhamad Ghazal; Matthias Kern
Journal:  J Prosthet Dent       Date:  2008-11       Impact factor: 3.426

5.  Evaluation of the accuracy of interocclusal records in relation to two recording techniques.

Authors:  A P Tripodakis; V K Vergos; A G Tsoutsos
Journal:  J Prosthet Dent       Date:  1997-02       Impact factor: 3.426

6.  Resin registration for interocclusal records.

Authors:  H Skurnik
Journal:  J Prosthet Dent       Date:  1977-02       Impact factor: 3.426

7.  Centric relation records: the effect of muscle action.

Authors:  H C Lundeen
Journal:  J Prosthet Dent       Date:  1974-03       Impact factor: 3.426

8.  Determination of the accuracy of wax interocclusal registrations.

Authors:  P L Millstein; J H Kronman; R E Clark
Journal:  J Prosthet Dent       Date:  1971-02       Impact factor: 3.426

9.  Daily variations in occlusal contacts.

Authors:  D C Berry; B P Singh
Journal:  J Prosthet Dent       Date:  1983-09       Impact factor: 3.426

10.  Clinical evaluation of interocclusal recording materials in bilateral free end cases.

Authors:  Valéria de Oliveira Pagnano; Osvaldo Luiz Bezzon; Maria da Glória Chiarello de Mattos; Ricardo Faria Ribeiro; Miriam Lacalle Turbino
Journal:  Braz Dent J       Date:  2005
View more
  5 in total

1.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

2.  Comparison of disinfectants by immersion and spray atomization techniques on the linear dimensional stability of different interocclusal recording materials: An in vitro study.

Authors:  Revathy Gounder; B V J Vikas
Journal:  Eur J Dent       Date:  2016 Jan-Mar

3.  Accuracy of several implant bite registration techniques: an in-vitro pilot study.

Authors:  Do-Hyun Park; Ji-Man Park; Jae-Won Choi; Eun-Sook Kang; Eun-Bin Bae; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

4.  Evaluation of the Elastic Properties of Thirteen Silicone Interocclusal Recording Materials.

Authors:  Mieszko Wieckiewicz; Natalia Grychowska; Marek Zietek; Wlodzimierz Wieckiewicz
Journal:  Biomed Res Int       Date:  2016-09-26       Impact factor: 3.411

5.  Evaluation of Dimensional Stability and Surface Hardness of Interocclusal Recording Materials at Various Time Intervals: An in vitro Study.

Authors:  Prince Kumar; Ajay Pravin Pacharne; Sunil Kumar Mishra
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.