Literature DB >> 27659820

The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children. : Part II: age-related ONSD cut-off values and patency of the anterior fontanelle.

Llewellyn C Padayachy1, Vaishali Padayachy2, Ushma Galal3, Travis Pollock4, A Graham Fieggen5.   

Abstract

PURPOSE: To analyse the diagnostic accuracy of age-related optic nerve sheath diameter (ONSD) cut-off values in children for detecting raised intracranial pressure (ICP) and to assess the benefit of using patency of the anterior fontanelle in describing a different set of cut-off values.
METHODS: The ONSD measurement was performed prior to invasive ICP measurement in children under general anesthesia. The diagnostic accuracy of the ONSD measurement was compared to ICP at thresholds of 20, 15, 10, and 5 mmHg. This was further analysed in children above and below the age of 1 year, with a subgroup analysis of age at 4 years, and assessment of the anterior fontanelle (AF) as a reliable physiological marker in part II of this study.
RESULTS: Data from 174 children were analysed. In children ≤1 year old, the ONSD measurement with the best diagnostic accuracy for detecting ICP ≥ 20 mmHg was 5.16 mm, compared to 5.75 mm in children >1 year old (p < 0.001). In addition, patency of the anterior fontanelle (AF) was found to be a useful clinical marker for defining different ONSD cut-off values at ICP thresholds of 20, 15, 10 and 5 mmHg.
CONCLUSION: Transorbital ultrasound measurement of the ONSD is a reliable non-invasive marker of ICP particularly at higher thresholds of 20 and 15 mmHg. Patency of the AF is a useful clinical marker for defining different ONSD cut-off values in children.

Entities:  

Keywords:  ICP monitoring; Non-invasive; Optic nerve sheath diameter; Ultrasound

Mesh:

Year:  2016        PMID: 27659820     DOI: 10.1007/s00381-016-3068-4

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  24 in total

1.  Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients.

Authors:  Vivek S Tayal; Matthew Neulander; H James Norton; Troy Foster; Timothy Saunders; Michael Blaivas
Journal:  Ann Emerg Med       Date:  2006-09-25       Impact factor: 5.721

2.  Guidelines for the management of severe traumatic brain injury. VI. Indications for intracranial pressure monitoring.

Authors:  Susan L Bratton; Randall M Chestnut; Jamshid Ghajar; Flora F McConnell Hammond; Odette A Harris; Roger Hartl; Geoffrey T Manley; Andrew Nemecek; David W Newell; Guy Rosenthal; Joost Schouten; Lori Shutter; Shelly D Timmons; Jamie S Ullman; Walter Videtta; Jack E Wilberger; David W Wright
Journal:  J Neurotrauma       Date:  2007       Impact factor: 5.269

Review 3.  Intracranial pressure monitoring for traumatic brain injury in the modern era.

Authors:  Llewellyn C Padayachy; Anthony A Figaji; M R Bullock
Journal:  Childs Nerv Syst       Date:  2010-04       Impact factor: 1.475

Review 4.  Ultrasonography of the optic nerve in neurocritically ill patients.

Authors:  R Moretti; B Pizzi
Journal:  Acta Anaesthesiol Scand       Date:  2011-04-04       Impact factor: 2.105

5.  Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents.

Authors:  M Steinborn; M Friedmann; H Hahn; A Hapfelmeier; E Macdonald; K Warncke; A Saleh
Journal:  Ultraschall Med       Date:  2014-08-20       Impact factor: 6.548

6.  Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.

Authors:  W D Newman; A S Hollman; G N Dutton; R Carachi
Journal:  Br J Ophthalmol       Date:  2002-10       Impact factor: 4.638

7.  Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus.

Authors:  David McAuley; Anne Paterson; Louise Sweeney
Journal:  Childs Nerv Syst       Date:  2008-09-23       Impact factor: 1.475

Review 8.  Measurement of intracranial pressure in children: a critical review of current methods.

Authors:  C Wiegand; P Richards
Journal:  Dev Med Child Neurol       Date:  2007-12       Impact factor: 5.449

Review 9.  Monitoring and interpretation of intracranial pressure.

Authors:  M Czosnyka; J D Pickard
Journal:  J Neurol Neurosurg Psychiatry       Date:  2004-06       Impact factor: 10.154

10.  Pulsatile Dynamics of the Optic Nerve Sheath and Intracranial Pressure: An Exploratory In Vivo Investigation.

Authors:  Llewellyn Padayachy; Reidar Brekken; Graham Fieggen; Tormod Selbekk
Journal:  Neurosurgery       Date:  2016-07       Impact factor: 4.654

View more
  21 in total

Review 1.  Non-invasive intracranial pressure assessment.

Authors:  Llewellyn C Padayachy
Journal:  Childs Nerv Syst       Date:  2016-07-21       Impact factor: 1.475

2.  Ultrasound non-invasive intracranial pressure assessment in paediatric neurocritical care: a pilot study.

Authors:  Chiara Robba; Danilo Cardim; Marek Czosnyka; Francisco Abecasis; Stefano Pezzato; Silvia Buratti; Andrea Moscatelli; Cristina Sortica; Fabrizio Racca; Paolo Pelosi; Frank Rasulo
Journal:  Childs Nerv Syst       Date:  2019-06-15       Impact factor: 1.475

3.  Use of neuroimaging measurements of optic nerve sheath diameter to assess intracranial pressure in craniosynostosis.

Authors:  Mostafa Haredy; Giulio Zuccoli; Mandeep Tamber; Amani Davis; Ken Nischal; Jesse A Goldstein
Journal:  Childs Nerv Syst       Date:  2018-01-29       Impact factor: 1.475

4.  Non-invasive assessment of ICP in children: advances in ultrasound-based techniques.

Authors:  Llewellyn C Padayachy; C Robba; R Brekken
Journal:  Childs Nerv Syst       Date:  2019-10-04       Impact factor: 1.475

5.  The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - Part II: Influence of wakefulness, method of ICP measurement, intra-individual ONSD-ICP correlation and changes after therapy.

Authors:  Susanne R Kerscher; Daniel Schöni; Felix Neunhoeffer; Markus Wolff; Karin Haas-Lude; Andrea Bevot; Martin U Schuhmann
Journal:  Childs Nerv Syst       Date:  2019-08-08       Impact factor: 1.475

6.  The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - Part I: Correlations, age-dependency and cut-off values.

Authors:  Susanne R Kerscher; Daniel Schöni; Helene Hurth; Felix Neunhoeffer; Karin Haas-Lude; Markus Wolff; Martin U Schuhmann
Journal:  Childs Nerv Syst       Date:  2019-06-29       Impact factor: 1.475

7.  Effect of dexmedetomidine on intracranial pressure in patients undergoing gynecological laparoscopic surgery in Trendelenburg position through ultrasonographic measurement of optic nerve sheath diameter.

Authors:  Ting Zhu; Chen Yuan; Meijuan Qian; Lihong Zhao; Hui Li; Yang Xie
Journal:  Am J Transl Res       Date:  2022-09-15       Impact factor: 3.940

8.  Predictive Value of Optic Nerve Sheath Diameter for Diagnosis of Intracranial Hypertension in Children With Severe Brain Injury.

Authors:  Fleur Cour-Andlauer; Aurélie Portefaix; Isabelle Wroblewski; Muriel Rabilloud; Fabienne Bordet; Bérengère Cogniat; Capucine Didier; Robin Pouyau; Frédéric V Valla; Behrouz Kassai-Koupai; Gaëlle Siméon; Tiphanie Ginhoux; Sonia Courtil-Teyssedre; Etienne Javouhey
Journal:  Front Pediatr       Date:  2022-06-06       Impact factor: 3.569

9.  Optic nerve sheath diameter does not correlate with intracranial pressure in pediatric neurocritical care patients.

Authors:  Austin Biggs; Marlina Lovett; Melissa Moore-Clingenpeel; Nicole O'Brien
Journal:  Childs Nerv Syst       Date:  2020-10-03       Impact factor: 1.475

Review 10.  Is Ocular Sonography a Reliable Method for the Assessment of Elevated Intracranial Pressure in Children?

Authors:  Dincer Yildizdas; Nagehan Aslan
Journal:  J Pediatr Intensive Care       Date:  2020-09-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.