Literature DB >> 16997419

Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients.

Vivek S Tayal1, Matthew Neulander, H James Norton, Troy Foster, Timothy Saunders, Michael Blaivas.   

Abstract

STUDY
OBJECTIVE: Our objective is to determine whether a bedside ultrasonographic measurement of optic nerve sheath diameter can accurately predict the computed tomographic (CT) findings of elevated intracranial pressure in adult head injury patients in the emergency department (ED).
METHODS: We conducted a prospective, blinded observational study on adult ED patients with suspected intracranial injury with possible elevated intracranial pressure. Exclusion criteria were age younger than 18 years or obvious ocular trauma. Using a 7.5-MHz ultrasonographic probe on the closed eyelids, a single optic nerve sheath diameter was measured 3 mm behind the globe in each eye. A mean binocular optic nerve sheath diameter greater than 5.00 mm was considered abnormal. Cranial CT findings of shift, edema, or effacement suggestive of elevated intracranial pressure were used to evaluate optic nerve sheath diameter accuracy.
RESULTS: Fifty-nine patients were enrolled in the study. Average age was 38 years, and median Glasgow Coma Scale score was 15 (interquartile 6 to 15). Eight patients with an optic nerve sheath diameter of 5.00 mm or more had CT findings that correlated with elevated intracranial pressure. The sensitivity for the ultrasonography in detecting elevated intracranial pressure was 100% (95% confidence interval [CI] 68% to 100%) and specificity was 63% (95% CI 50% to 76%). The sensitivity of ultrasonography for detection of any traumatic intracranial injury found by CT was 84% (95% CI 60% to 97%) and specificity was 73% (95% CI 59% to 86%).
CONCLUSION: Bedside ED optic nerve sheath diameter ultrasonography has potential as a sensitive screening test for elevated intracranial pressure in adult head injury.

Entities:  

Mesh:

Year:  2006        PMID: 16997419     DOI: 10.1016/j.annemergmed.2006.06.040

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  102 in total

1.  Intraocular pressure correlates with optic nerve sheath diameter in patients with normal tension glaucoma.

Authors:  Luís Abegão Pinto; Evelien Vandewalle; Anna Pronk; Ingeborg Stalmans
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-12-10       Impact factor: 3.117

2.  Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.

Authors:  Eun Jung Kim; Bon-Nyeo Koo; Seung Ho Choi; Kyoungun Park; Min-Soo Kim
Journal:  Surg Endosc       Date:  2017-06-21       Impact factor: 4.584

3.  Optic nerve ultrasound: artifacts and real images.

Authors:  Roberto Copetti; Luigi Cattarossi
Journal:  Intensive Care Med       Date:  2009-04-15       Impact factor: 17.440

4.  Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage.

Authors:  Riccardo Moretti; Barbara Pizzi; Fabrizio Cassini; Nicoletta Vivaldi
Journal:  Neurocrit Care       Date:  2009-12       Impact factor: 3.210

5.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 6.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

Review 7.  Optic nerve sheath diameter: present and future perspectives for neurologists and critical care physicians.

Authors:  Piergiorgio Lochner; Marek Czosnyka; Andrea Naldi; Epameinondas Lyros; Paolo Pelosi; Shrey Mathur; Klaus Fassbender; Chiara Robba
Journal:  Neurol Sci       Date:  2019-07-31       Impact factor: 3.307

Review 8.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

9.  Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure.

Authors:  Li-Juan Wang; Li-Min Chen; Ying Chen; Li-Yang Bao; Nan-Nan Zheng; Yu-Zhi Wang; Ying-Qi Xing
Journal:  JAMA Ophthalmol       Date:  2018-03-01       Impact factor: 7.389

10.  Analysis of cerebral blood flow and intracranial hypertension in critical patients with non-hepatic hyperammonemia.

Authors:  Alexandre Sanches Larangeira; Marcos Toshiyuki Tanita; Marcos Antonio Dias; Olavo Franco Ferreira Filho; Vinicius Daher Alvares Delfino; Lucienne Tibery Queiroz Cardoso; Cintia Magalhães Carvalho Grion
Journal:  Metab Brain Dis       Date:  2018-05-03       Impact factor: 3.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.