Literature DB >> 18810461

Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus.

David McAuley1, Anne Paterson, Louise Sweeney.   

Abstract

OBJECTS: Optic nerve sheath diameter has been linked with intracranial pressure in previous studies. Measurement of sheath diameter using transorbital ultrasound is proposed as a clinical assessment indicator of developing hydrocephalus in the paediatric population.
METHODS: A retrospective review of optic nerve sheath ultrasound examinations performed in a clinical setting between 2000 and 2006 for assessment of hydrocephalus in a single institution.
RESULTS: A total of 331 examinations were performed in 160 patients over the study period. A satisfactory image was possible in all cases. Sheath diameters were correlated with clinical case data from concurrent case records.
CONCLUSION: Transorbital ultrasound is a reproducible, non-invasive technique for the assessment of optic nerve sheath diameter and is well tolerated in children. Our series revealed asymptomatic baseline value higher than in previous reports. Variation from individual case asymptomatic baseline was the most sensitive variable in the series in determining development of hydrocephalus. This technique is felt to be a useful adjunct in the assessment of hydrocephalus in the paediatric neurosurgical population.

Entities:  

Mesh:

Year:  2008        PMID: 18810461     DOI: 10.1007/s00381-008-0713-6

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  5 in total

1.  Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study.

Authors:  K Helmke; H C Hansen
Journal:  Pediatr Radiol       Date:  1996-10

2.  The subarachnoid space surrounding the optic nerves. An ultrasound study of the optic nerve sheath.

Authors:  H C Hansen; K Helmke
Journal:  Surg Radiol Anat       Date:  1996       Impact factor: 1.246

3.  Transorbital optic nerve sheath ultrasonography in normal children.

Authors:  J Ballantyne; A S Hollman; R Hamilton; M S Bradnam; R Carachi; D G Young; G N Dutton
Journal:  Clin Radiol       Date:  1999-11       Impact factor: 2.350

4.  Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study.

Authors:  K Helmke; H C Hansen
Journal:  Pediatr Radiol       Date:  1996-10

5.  Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.

Authors:  W D Newman; A S Hollman; G N Dutton; R Carachi
Journal:  Br J Ophthalmol       Date:  2002-10       Impact factor: 4.638

  5 in total
  17 in total

1.  Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.

Authors:  Eun Jung Kim; Bon-Nyeo Koo; Seung Ho Choi; Kyoungun Park; Min-Soo Kim
Journal:  Surg Endosc       Date:  2017-06-21       Impact factor: 4.584

2.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 3.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

Review 4.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

5.  Cerebral biometry at birth and at 4 and 8 months of age. A prospective study using US.

Authors:  Joost Gravendeel; Karen Rosendahl
Journal:  Pediatr Radiol       Date:  2010-07-30

6.  High resolution transbulbar sonography in children with suspicion of increased intracranial pressure.

Authors:  Marc Steinborn; Melanie Friedmann; Christine Makowski; Helmut Hahn; Alexander Hapfelmeier; Hendrik Juenger
Journal:  Childs Nerv Syst       Date:  2016-01-13       Impact factor: 1.475

7.  Optic nerve sheath diameter measurements by CT scan in ventriculoperitoneal shunt obstruction.

Authors:  Syed Javed H Zaidi; Loren G Yamamoto
Journal:  Hawaii J Med Public Health       Date:  2014-08

8.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children. : Part II: age-related ONSD cut-off values and patency of the anterior fontanelle.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Travis Pollock; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

9.  Change in optic nerve sheath diameter as a radiological marker of outcome from endoscopic third ventriculostomy in children.

Authors:  Llewellyn C Padayachy; Tracy Kilborn; Henri Carrara; Anthony A Figaji; Graham A Fieggen
Journal:  Childs Nerv Syst       Date:  2015-03-04       Impact factor: 1.475

10.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Rebecca Gray; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.