Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents.

M Steinborn1, M Friedmann1, H Hahn2, A Hapfelmeier3, E Macdonald1, K Warncke2, A Saleh1.   

Abstract

PURPOSE: To establish normal values of the optic nerve sheath diameter (ONSD) in children and adolescents for transbulbar sonography and magnetic resonance imaging.
MATERIALS AND METHODS: In 99 children and adolescents (age: 5.6 - 18.6 years, mean: 12 years) without neurologic or ophthalmologic disease, measurements of the ONSD with transbulbar sonography were performed. For comparison 59 children and adolescents (age: 5.1 - 17.4 years, mean 12.3 years) with a normal MR examination of the brain had measurements of the ONSD on a T2-weighted thin section sequence of the orbit. Besides establishing modality-related normal values, age dependency, accuracy and reproducibility of measurements were assessed.
RESULTS: Overall the mean ONSD was 5.75 ± 0.52 mm for transbulbar sonography and 5.69 ± 0.31 mm for MRI. There was no statistical significance between the 95 % percentiles and age for both transbulbar sonography (p = 0.332) and MRI (p = 0.336). As a parameter for the reproducibility of measurements, the repeatability coefficient (RC) was between 0.34 mm and 0.46 mm. The concordance correlation coefficient (CCC) values revealed a high agreement between readers both for transbulbar sonography (0.868) and MRI (0.796).
CONCLUSION: Normal values for ONSD in children and adolescents found in this study are significantly higher than assumed. The values found for transbulbar sonography are confirmed by comparable results for MR measurements. A precise sonographic measurement technique and the consideration of normal values found hereby are essential for correct interpretation of ONSD measurements in children and adolescents. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2014        PMID: 25140497     DOI: 10.1055/s-0034-1385012

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  15 in total

1.  Pediatric optic nerve and optic nerve sheath diameter on magnetic resonance imaging.

Authors:  Pun Janthanimi; Netsiri Dumrongpisutikul
Journal:  Pediatr Radiol       Date:  2019-05-02

2.  Diagnostic value of neuro-ophthalmological signs in cases of Chiari I malformation.

Authors:  Inessa Bekerman; Tal Sigal; Itzhak Kimiagar; Zina Evy Almer; Michael Vaiman
Journal:  Childs Nerv Syst       Date:  2016-11-08       Impact factor: 1.475

3.  High resolution transbulbar sonography in children with suspicion of increased intracranial pressure.

Authors:  Marc Steinborn; Melanie Friedmann; Christine Makowski; Helmut Hahn; Alexander Hapfelmeier; Hendrik Juenger
Journal:  Childs Nerv Syst       Date:  2016-01-13       Impact factor: 1.475

Review 4.  Non-invasive intracranial pressure assessment.

Authors:  Llewellyn C Padayachy
Journal:  Childs Nerv Syst       Date:  2016-07-21       Impact factor: 1.475

5.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children. : Part II: age-related ONSD cut-off values and patency of the anterior fontanelle.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Travis Pollock; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

6.  Use of neuroimaging measurements of optic nerve sheath diameter to assess intracranial pressure in craniosynostosis.

Authors:  Mostafa Haredy; Giulio Zuccoli; Mandeep Tamber; Amani Davis; Ken Nischal; Jesse A Goldstein
Journal:  Childs Nerv Syst       Date:  2018-01-29       Impact factor: 1.475

7.  Optic Nerve Measurement on MRI in the Pediatric Population: Normative Values and Correlations.

Authors:  C E Al-Haddad; M G Sebaaly; R N Tutunji; C J Mehanna; S R Saaybi; A M Khamis; R G Hourani
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-07       Impact factor: 3.825

8.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Rebecca Gray; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

9.  Optic nerve sheath diameter does not correlate with intracranial pressure in pediatric neurocritical care patients.

Authors:  Austin Biggs; Marlina Lovett; Melissa Moore-Clingenpeel; Nicole O'Brien
Journal:  Childs Nerv Syst       Date:  2020-10-03       Impact factor: 1.475

Review 10.  Is Ocular Sonography a Reliable Method for the Assessment of Elevated Intracranial Pressure in Children?

Authors:  Dincer Yildizdas; Nagehan Aslan
Journal:  J Pediatr Intensive Care       Date:  2020-09-07