Literature DB >> 12234888

Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.

W D Newman1, A S Hollman, G N Dutton, R Carachi.   

Abstract

AIM: To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure.
METHODS: 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or carers. The shunt valve was examined clinically, and signs of raised intracranial pressure were sought. Ultrasound examination was performed in both eyes to measure the optic nerve sheath diameters 3 mm behind the globe. These measurements were compared with control data obtained from 102 children who attended the radiology department for unrelated renal ultrasound examination.
RESULTS: Control data suggested that the upper limit of normal for optic nerve sheath diameter is 4.5 mm (measured 3 mm behind the globe) in patients over 1 year of age, and 4.0 mm in children less than 1 year of age. Those patients with functioning ventriculoperitoneal shunts had a mean optic nerve sheath diameter of 2.9 (SD 0.5) mm; those with raised intracranial pressure had a mean optic nerve sheath diameter of 5.6 (0.6) mm (p<0.0001). These results confirm that optic nerve sheath diameters in excess of the control data are strongly suggestive of raised intracranial pressure.
CONCLUSION: The evaluation of the optic nerve sheath diameter is a simple non-invasive procedure, which is a potentially useful tool in the assessment and monitoring of children with hydrocephalus suspected of having raised intracranial pressure.

Entities:  

Mesh:

Year:  2002        PMID: 12234888      PMCID: PMC1771326          DOI: 10.1136/bjo.86.10.1109

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  7 in total

1.  Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study.

Authors:  K Helmke; H C Hansen
Journal:  Pediatr Radiol       Date:  1996-10

2.  The subarachnoid space surrounding the optic nerves. An ultrasound study of the optic nerve sheath.

Authors:  H C Hansen; K Helmke
Journal:  Surg Radiol Anat       Date:  1996       Impact factor: 1.246

Review 3.  Standardized echography: basic principles, clinical applications, and results.

Authors:  K C Ossoinig
Journal:  Int Ophthalmol Clin       Date:  1979

4.  Transorbital optic nerve sheath ultrasonography in normal children.

Authors:  J Ballantyne; A S Hollman; R Hamilton; M S Bradnam; R Carachi; D G Young; G N Dutton
Journal:  Clin Radiol       Date:  1999-11       Impact factor: 2.350

5.  Measurement and relationship of subarachnoid pressure of the optic nerve to intracranial pressures in fresh cadavers.

Authors:  D Liu; M Kahn
Journal:  Am J Ophthalmol       Date:  1993-11-15       Impact factor: 5.258

6.  Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study.

Authors:  K Helmke; H C Hansen
Journal:  Pediatr Radiol       Date:  1996-10

7.  Echographic measurement of the optic nerve in patients with intracranial hypertension.

Authors:  M Gangemi; G Cennamo; F Maiuri; F D'Andrea
Journal:  Neurochirurgia (Stuttg)       Date:  1987-03
  7 in total
  78 in total

Review 1.  An experience of emergency ultrasonography in children in a sub-Saharan setting.

Authors:  S Ahmad; S Kampondeni; E Molyneux
Journal:  Emerg Med J       Date:  2006-05       Impact factor: 2.740

2.  A finite element infant eye model to investigate retinal forces in shaken baby syndrome.

Authors:  Steven Alex Hans; Sebastian Y Bawab; Michael L Woodhouse
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-12-04       Impact factor: 3.117

3.  Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage.

Authors:  Riccardo Moretti; Barbara Pizzi; Fabrizio Cassini; Nicoletta Vivaldi
Journal:  Neurocrit Care       Date:  2009-12       Impact factor: 3.210

4.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 5.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

6.  Transorbital sonographic measurement of normal optic sheath nerve diameter in nigerian adult population.

Authors:  Ismail Anas
Journal:  Malays J Med Sci       Date:  2014 Sep-Oct

7.  Optic nerve sheath diameter as criteria for endoscopic third ventriculostomy failure in children.

Authors:  Llewellyn C Padayachy; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2015-06-18       Impact factor: 1.475

8.  Constructing a statistical atlas of the radii of the optic nerve and cerebrospinal fluid sheath in young healthy adults.

Authors:  Robert L Harrigan; Andrew J Plassard; Louise A Mawn; Robert L Galloway; Seth A Smith; Bennett A Landman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-20

9.  Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus.

Authors:  David McAuley; Anne Paterson; Louise Sweeney
Journal:  Childs Nerv Syst       Date:  2008-09-23       Impact factor: 1.475

10.  Detection of raised intracranial pressure by ultrasound measurement of optic nerve sheath diameter in African children.

Authors:  Nicholas A V Beare; Sam Kampondeni; Simon J Glover; Elizabeth Molyneux; Terrie E Taylor; Simon P Harding; Malcolm E Molyneux
Journal:  Trop Med Int Health       Date:  2008-10-13       Impact factor: 2.622

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.