Literature DB >> 21463263

Ultrasonography of the optic nerve in neurocritically ill patients.

R Moretti1, B Pizzi.   

Abstract

The rapid diagnosis of intracranial hypertension is urgently needed for therapeutic reasons in various clinical settings. This can rarely be achieved without invasive procedures such as intracranial pressure (ICP) monitoring or neuroimaging. The optic nerve is surrounded by cerebrospinal fluid (CSF) and dura mater, which forms the optic nerve sheath (ONS). Because of the connection with the intracranial subarachnoid space, ONS diameter (ONSD) is influenced by CSF pressure variations. Bedside ultrasonographic measurement of ONSD has been proposed as a non-invasive and reliable means to detect raised ICP in neurocritically ill patients. In several studies, it proves to have a good correlation with the direct measurement of ICP and a low interobserver variability. However, no general consensus exists over the upper normal ONSD limit. We performed a review of the literature on the use of the ultrasonography of the optic nerve in the evaluation of patients with suspected intracranial hypertension. The aim of this review is to describe the technique and to assess the validity of this diagnostic method.
© 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2011        PMID: 21463263     DOI: 10.1111/j.1399-6576.2011.02432.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  39 in total

1.  Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.

Authors:  Eun Jung Kim; Bon-Nyeo Koo; Seung Ho Choi; Kyoungun Park; Min-Soo Kim
Journal:  Surg Endosc       Date:  2017-06-21       Impact factor: 4.584

2.  Dynamic Optic Nerve Sheath Diameter (ONSD) guided management of raised intracranial pressure in pediatric acute liver failure.

Authors:  Priti Vijay; Bikrant Bihari Lal; Vikrant Sood; Rajeev Khanna; Yashwant Patidar; Seema Alam
Journal:  Hepatol Int       Date:  2021-02-24       Impact factor: 6.047

3.  Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis.

Authors:  Chiara Robba; Gregorio Santori; Marek Czosnyka; Francesco Corradi; Nicola Bragazzi; Llewellyn Padayachy; Fabio Silvio Taccone; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2018-07-17       Impact factor: 17.440

Review 4.  Non-invasive intracranial pressure assessment.

Authors:  Llewellyn C Padayachy
Journal:  Childs Nerv Syst       Date:  2016-07-21       Impact factor: 1.475

5.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children. : Part II: age-related ONSD cut-off values and patency of the anterior fontanelle.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Travis Pollock; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

6.  A method for estimating zero-flow pressure and intracranial pressure.

Authors:  Caren Marzban; Paul R Illian; David Morison; Anne Moore; Michel Kliot; Marek Czosnyka; Pierre D Mourad
Journal:  J Neurosurg Anesthesiol       Date:  2013-01       Impact factor: 3.956

7.  Association between optic nerve sheath diameter and mortality in patients with severe traumatic brain injury.

Authors:  Mypinder S Sekhon; Paul McBeth; Jie Zou; Lu Qiao; Leif Kolmodin; William R Henderson; Steve Reynolds; Donald E G Griesdale
Journal:  Neurocrit Care       Date:  2014-10       Impact factor: 3.210

8.  The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

Authors:  Llewellyn C Padayachy; Vaishali Padayachy; Ushma Galal; Rebecca Gray; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2016-09-20       Impact factor: 1.475

Review 9.  Intraoperative non invasive intracranial pressure monitoring during pneumoperitoneum: a case report and a review of the published cases and case report series.

Authors:  C Robba; S Bacigaluppi; D Cardim; J Donnelly; M S Sekhon; M J Aries; G Mancardi; A Booth; N L Bragazzi; M Czosnyka; B Matta
Journal:  J Clin Monit Comput       Date:  2015-09-05       Impact factor: 2.502

10.  Correlating optic nerve sheath diameter with opening intracranial pressure in pediatric traumatic brain injury.

Authors:  Adam M H Young; Mathew R Guilfoyle; Joseph Donnelly; Daniel Scoffings; Helen Fernandes; Mathew Garnett; Shruti Agrawal; Peter J Hutchinson
Journal:  Pediatr Res       Date:  2016-08-11       Impact factor: 3.756

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.