Literature DB >> 27612300

Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

Thomas Benkert1,2, Li Feng1,2, Daniel K Sodickson1,2, Hersh Chandarana1,2, Kai Tobias Block1,2.   

Abstract

PURPOSE: Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation.
METHODS: Multiecho data are acquired using a motion-robust radial stack-of-stars three-dimensional GRE sequence with bipolar readout. To obtain fat/water maps, a model-based reconstruction is used that accounts for the off-resonant blurring of fat and integrates both compressed sensing and parallel imaging. The approach additionally enables generation of respiration-resolved fat/water maps by detecting motion from k-space data and reconstructing different respiration states. Furthermore, an extension is described for dynamic contrast-enhanced fat-water-separated measurements.
RESULTS: Uniform and robust fat/water separation is demonstrated in several clinical applications, including free-breathing noncontrast abdominal examination of adults and a pediatric subject with both motion-averaged and motion-resolved reconstructions, as well as in a noncontrast breast exam. Furthermore, dynamic contrast-enhanced fat/water imaging with high temporal resolution is demonstrated in the abdomen and breast.
CONCLUSION: The described framework provides a viable approach for motion-robust fat/water separation and promises particular value for clinical applications that are currently limited by the breath-holding capacity or cooperation of patients. Magn Reson Med 78:565-576, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  Dixon imaging; compressed sensing; fat/water separation; free-breathing; radial sampling

Mesh:

Substances:

Year:  2016        PMID: 27612300      PMCID: PMC5344788          DOI: 10.1002/mrm.26392

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  37 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Chemical species separation with simultaneous estimation of field map and T2* using a k-space formulation.

Authors:  Jose Luis Honorato; Vicente Parot; Cristian Tejos; Sergio Uribe; Pablo Irarrazaval
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

3.  Array compression for MRI with large coil arrays.

Authors:  Martin Buehrer; Klaas P Pruessmann; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

Review 4.  Fat and water magnetic resonance imaging.

Authors:  Thorsten A Bley; Oliver Wieben; Christopher J François; Jean H Brittain; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2010-01       Impact factor: 4.813

Review 5.  Chemical shift encoding-based water-fat separation methods.

Authors:  Holger Eggers; Peter Börnert
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

6.  Respiratory Motion-Resolved Compressed Sensing Reconstruction of Free-Breathing Radial Acquisition for Dynamic Liver Magnetic Resonance Imaging.

Authors:  Hersh Chandarana; Li Feng; Justin Ream; Annie Wang; James S Babb; Kai Tobias Block; Daniel K Sodickson; Ricardo Otazo
Journal:  Invest Radiol       Date:  2015-11       Impact factor: 6.016

7.  Z intensity-weighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging.

Authors:  Pascal Spincemaille; Jing Liu; Thanh Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Imaging       Date:  2011-04-27       Impact factor: 2.546

8.  Retrospective respiratory self-gating and removal of bulk motion in pulmonary UTE MRI of neonates and adults.

Authors:  Nara S Higano; Andrew D Hahn; Jean A Tkach; Xuefeng Cao; Laura L Walkup; Robert P Thomen; Stephanie L Merhar; Paul S Kingma; Sean B Fain; Jason C Woods
Journal:  Magn Reson Med       Date:  2016-03-12       Impact factor: 4.668

9.  Anisotropic field-of-view support for golden angle radial imaging.

Authors:  Ziyue Wu; Fei Han; Peng Hu; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2015-08-24       Impact factor: 4.668

Review 10.  Fat and iron quantification in the liver: past, present, and future.

Authors:  Takeshi Yokoo; Jeffrey D Browning
Journal:  Top Magn Reson Imaging       Date:  2014-04
View more
  19 in total

1.  Rigid-body motion correction of the liver in image reconstruction for golden-angle stack-of-stars DCE MRI.

Authors:  Adam Johansson; James Balter; Yue Cao
Journal:  Magn Reson Med       Date:  2017-06-15       Impact factor: 4.668

2.  Hybrid T2 - and T1 -weighted radial acquisition for free-breathing abdominal examination.

Authors:  Thomas Benkert; John P Mugler; David S Rigie; Daniel K Sodickson; Hersh Chandarana; Kai Tobias Block
Journal:  Magn Reson Med       Date:  2018-04-15       Impact factor: 4.668

3.  Abdominal DCE-MRI reconstruction with deformable motion correction for liver perfusion quantification.

Authors:  Adam Johansson; James M Balter; Yue Cao
Journal:  Med Phys       Date:  2018-08-31       Impact factor: 4.071

4.  Dynamic Contrast-enhanced MRI Detects Responses to Stroma-directed Therapy in Mouse Models of Pancreatic Ductal Adenocarcinoma.

Authors:  Jianbo Cao; Stephen Pickup; Cynthia Clendenin; Barbara Blouw; Hoon Choi; David Kang; Mark Rosen; Peter J O'Dwyer; Rong Zhou
Journal:  Clin Cancer Res       Date:  2018-12-26       Impact factor: 12.531

Review 5.  Compressed sensing for body MRI.

Authors:  Li Feng; Thomas Benkert; Kai Tobias Block; Daniel K Sodickson; Ricardo Otazo; Hersh Chandarana
Journal:  J Magn Reson Imaging       Date:  2016-12-16       Impact factor: 4.813

6.  Volumetric multicomponent T relaxation mapping of the human liver under free breathing at 3T.

Authors:  Azadeh Sharafi; Rahman Baboli; Marcelo Zibetti; Krishna Shanbhogue; Sonja Olsen; Tobias Block; Hersh Chandarana; Ravinder Regatte
Journal:  Magn Reson Med       Date:  2019-11-14       Impact factor: 4.668

7.  Free-breathing 3-D quantification of infant body composition and hepatic fat using a stack-of-radial magnetic resonance imaging technique.

Authors:  Tess Armstrong; Karrie V Ly; Shahnaz Ghahremani; Kara L Calkins; Holden H Wu
Journal:  Pediatr Radiol       Date:  2019-04-17

Review 8.  Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging.

Authors:  Camilo Jaimes; John E Kirsch; Michael S Gee
Journal:  Pediatr Radiol       Date:  2018-08-04

9.  Optimization and validation of accelerated golden-angle radial sparse MRI reconstruction with self-calibrating GRAPPA operator gridding.

Authors:  Thomas Benkert; Ye Tian; Chenchan Huang; Edward V R DiBella; Hersh Chandarana; Li Feng
Journal:  Magn Reson Med       Date:  2017-11-28       Impact factor: 4.668

10.  Respiratory Motion Detection and Correction for MR Using the Pilot Tone: Applications for MR and Simultaneous PET/MR Examinations.

Authors:  Thomas Vahle; Mario Bacher; David Rigie; Matthias Fenchel; Peter Speier; Jan Bollenbeck; Klaus P Schäfers; Berthold Kiefer; Fernando E Boada
Journal:  Invest Radiol       Date:  2020-03       Impact factor: 6.016

View more