Literature DB >> 15342763

Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty.

Alejandro González Della Valle1, Adriana Zoppi, Margaret G E Peterson, Eduardo A Salvati.   

Abstract

BACKGROUND: First-generation cementless modular cups reproducibly achieved fixation to bone but were associated with unacceptable rates of pelvic osteolysis and mechanical failure. Consequently, second-generation cups were developed with shells that had a limited number of holes (or no holes) as well as improved locking mechanisms, a polished inner surface, and increased conformity with the liner. The purpose of the present study was to evaluate the clinical and radiographic results associated with the use of a second-generation acetabular component for primary total hip arthroplasty.
METHODS: Two hundred and ninety-seven patients underwent 335 consecutive primary total hip arthroplasties that were performed by a single surgeon with a second-generation modular acetabular component. All cups were implanted with a press-fit technique. Ten patients were lost to follow-up, and sixteen died from unrelated causes. The remaining 271 patients (308 hips) were followed clinically (with the Hospital for Special Surgery hip-scoring system) and radiographically for four to seven years.
RESULTS: One cup was revised because of aseptic loosening. There were seven additional revisions: five were performed because of aseptic loosening of the stem with a well-fixed cup, and two were performed because of deep infection. Among the 271 patients who were alive at the time of the last follow-up, 266 (98%) had retention of the cup and 264 (97%) had retention of both components with a good or excellent clinical result. In the group of 229 patients (262 hips) with complete radiographic follow-up, 259 cups were well fixed and the average wear rate (for the 246 hips for which this rate could be calculated) was 0.09 mm/yr. Osteolysis was detected in twelve hips (5%) and was associated with male gender (p = 0.001) and the annual wear rate (p = 0.004). The extent of calcar resorption was also associated with the annual wear rate (p < 0.001).
CONCLUSIONS: This second-generation acetabular cup design predictably achieved bone fixation and was associated with low rates of revision for loosening and osteolysis after intermediate-term follow-up.

Entities:  

Mesh:

Year:  2004        PMID: 15342763     DOI: 10.2106/00004623-200409000-00019

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  18 in total

1.  Is routine mid-term total hip arthroplasty surveillance beneficial?

Authors:  James A Keeney; Bradley S Ellison; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2012-06-06       Impact factor: 4.176

2.  Cementless acetabular component inserted without screws - the effect of immediate weight-bearing.

Authors:  F Y Ng; Y Zhu; K Y Chiu
Journal:  Int Orthop       Date:  2006-08-19       Impact factor: 3.075

3.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

4.  Wear is reduced in THA performed with highly cross-linked polyethylene.

Authors:  Burak Beksaç; Antonio Salas; Alejandro González Della Valle; Eduardo A Salvati
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

5.  Long-term results of the standard Wagner cup.

Authors:  Uwe Demmelmeyer; Annemarie Schraml; Wolfgang Hönle; Alexander Schuh
Journal:  Int Orthop       Date:  2009-04-08       Impact factor: 3.075

6.  Cementless modular neck stems: are they a safe option in primary total hip arthroplasty?

Authors:  José M Pelayo-de-Tomás; José L Rodrigo-Pérez; Carlos D Novoa-Parra; Alejandro Lizaur-Utrilla; María Morales-Suárez-Varela; José Antonio Blas-Dobón
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-29

7.  [Five-year survival rate of the Allofit titanium press-fit cup].

Authors:  K Schroeder; A Moehlenbruch; M Zimmermann-Stenzel; D Parsch
Journal:  Orthopade       Date:  2010-01       Impact factor: 1.087

8.  Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients.

Authors:  Hao Tang; Dejin Yang; Shengjie Guo; Jing Tang; Jian Liu; Dacheng Wang; Yixin Zhou
Journal:  Skeletal Radiol       Date:  2016-09-02       Impact factor: 2.199

9.  Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Adriana Zoppi; Eduardo A Salvati
Journal:  Int Orthop       Date:  2006-03-31       Impact factor: 3.075

10.  Cavitary acetabular defects treated with morselized cancellous bone graft and cementless cups.

Authors:  G C T Pereira; E N Kubiak; B Levine; F S Chen; P E Di Cesare
Journal:  Int Orthop       Date:  2006-09-19       Impact factor: 3.075