Literature DB >> 33914115

Prospective multicenter study on personalized and optimized MDCT contrast protocols: results on liver enhancement.

F Zanca1, H G Brat2, P Pujadas3, D Racine4, B Dufour2, D Fournier2, B Rizk5.   

Abstract

OBJECTIVE: To determine a personalized and optimized contrast injection protocol for a uniform and optimal diagnostic level of liver parenchymal enhancement, in a large patient population enrolled in a multicenter study.
METHODS: Six hundred ninety-two patients who underwent a standardized multi-phase liver CT examination were prospectively assigned to one contrast media (CM) protocol group: G1 (100 mL fixed volume, 37 gI); G2 (600 mgI/kg of total body weight (TBW)); G3 (750 mgI/kg of fat-free mass (FFM)), and G4 (600 mgI/kg of FFM). Change in liver parenchyma CT number between unenhanced and contrast-enhanced images was measured by two radiologists, on 3-mm pre-contrast and portal phase axial reconstructions. The enhancement histograms were compared across CM protocols, specifically according to a target diagnostic value of 50 HU. The total amount of iodine dose was also compared among protocols by median and interquartile range (IQR). The Kruskal-Wallis and Mann-Whitney U tests were used to assess significant differences (p < 0.005), as appropriate.
RESULTS: A significant difference (p < 0.001) was found across the groups with liver enhancement decreasing from median over-enhanced values of 77.0 (G1), 71.3 (G2), and 65.1 (G3) to a target enhancement of 53.2 HU for G4. Enhancement IQR was progressively reduced from 26.5 HU (G1), 26.0 HU (G2), and 17.8 HU (G3) to 14.5 HU (G4). G4 showed a median iodine dose of 26.0 gI, significantly lower (p < 0.001) than G3 (33.9 gI), G2 (38.8 gI), and G1 (37 gI).
CONCLUSIONS: The 600 mgI/kg FFM-based protocol enabled a diagnostically optimized liver enhancement and improved patient-to-patient enhancement uniformity, while significantly reducing iodine load. KEY POINTS: • Consistent and clinically adequate liver enhancement is observed with personalized and optimized contrast injection protocol. • Fat-free mass is an appropriate body size parameter for correlation with liver parenchymal enhancement. • Diagnostic oncology follow-up liver CT examinations may be obtained using 600 mgI/kg of FFM.
© 2021. European Society of Radiology.

Entities:  

Keywords:  Abdomen; Contrast media; Liver, body composition; Multidetector computed tomography

Mesh:

Substances:

Year:  2021        PMID: 33914115     DOI: 10.1007/s00330-021-07953-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  32 in total

Review 1.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

Review 2.  Optimal vascular and parenchymal contrast enhancement: the current state of the art.

Authors:  Dominik Fleischmann; Aya Kamaya
Journal:  Radiol Clin North Am       Date:  2009-01       Impact factor: 2.303

3.  Minimally Required Iodine Dose for the Detection of Hypervascular Hepatocellular Carcinoma on 80-kVp CT.

Authors:  Satoshi Goshima; Masayuki Kanematsu; Yoshifumi Noda; Nobuyuki Kawai; Hiroshi Kawada; Hiromi Ono; Kyongtae T Bae
Journal:  AJR Am J Roentgenol       Date:  2016-03       Impact factor: 3.959

4.  Simple weight-based contrast dosing for standardization of portal phase CT liver enhancement.

Authors:  M Benbow; R K Bull
Journal:  Clin Radiol       Date:  2011-07-02       Impact factor: 2.350

5.  The Optimal Body Size Index with Which to Determine Iodine Dose for Hepatic Dynamic CT: A Prospective Multicenter Study.

Authors:  Kazuo Awai; Masayuki Kanematsu; Tonsok Kim; Tomoaki Ichikawa; Yuko Nakamura; Atsushi Nakamoto; Kunihiro Yoshioka; Teruhito Mochizuki; Naofumi Matsunaga; Yasuyuki Yamashita
Journal:  Radiology       Date:  2015-09-10       Impact factor: 11.105

6.  Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction.

Authors:  Diomidis Botsikas; Isabelle Barnaure; Sylvain Terraz; Christoph D Becker; Anastasia Kalovidouri; Xavier Montet
Journal:  World J Radiol       Date:  2016-07-28

7.  Dual-phase helical CT of the liver: value of arterial phase scans in the detection of small (< or = 1.5 cm) malignant hepatic neoplasms.

Authors:  M D Hollett; R B Jeffrey; M Nino-Murcia; M J Jorgensen; D P Harris
Journal:  AJR Am J Roentgenol       Date:  1995-04       Impact factor: 3.959

8.  Implementation of patient-tailored contrast volumes based on body surface area and heart rate harmonizes contrast enhancement and reduces contrast load in small patients in portal venous phase abdominal CT.

Authors:  M-S Walgraeve; L Pyfferoen; K Van De Moortele; F Zanca; D Bielen; J W Casselman
Journal:  Eur J Radiol       Date:  2019-08-04       Impact factor: 3.528

9.  An Individually Optimized Protocol of Contrast Medium Injection in Enhanced CT Scan for Liver Imaging.

Authors:  Shi-Ting Feng; Hongzhang Zhu; Zhenpeng Peng; Li Huang; Zhi Dong; Ling Xu; Kun Huang; Xufeng Yang; Zhi Lin; Zi-Ping Li
Journal:  Contrast Media Mol Imaging       Date:  2017-07-10       Impact factor: 3.161

10.  Lean Body Weight-Tailored Iodinated Contrast Injection in Obese Patient: Boer versus James Formula.

Authors:  Damiano Caruso; Domenico De Santis; Flaminia Rivosecchi; Marta Zerunian; Nicola Panvini; Marta Montesano; Tommaso Biondi; Davide Bellini; Marco Rengo; Andrea Laghi
Journal:  Biomed Res Int       Date:  2018-08-13       Impact factor: 3.411

View more
  2 in total

1.  Multivariable Technique for the Evaluation of the Trans-stenotic Pressure Gradient.

Authors:  Junghun Kim; Jongmin Lee; Jieun Park
Journal:  Cardiovasc Eng Technol       Date:  2022-07-25       Impact factor: 2.305

Review 2.  MRI biomarkers in neuro-oncology.

Authors:  Marion Smits
Journal:  Nat Rev Neurol       Date:  2021-06-20       Impact factor: 42.937

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.