Literature DB >> 16799792

Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years.

Olav Reikerås1, Ragnhild B Gunderson.   

Abstract

INTRODUCTION: There are many studies on the short and medium term results of hydroxyapatite (HA) coated acetabular components, but information on survival in the longer run is sparse. In this paper, we report 11 to 16 years follow up results of HA coated threaded versus HA coated hemispherical press fit cups. PATIENTS AND METHODS: During the years 1988-1993, we performed 323 primary total hip replacements in 276 patients with an HA coated acetabular component. In 128 cases we used a HA coated threaded cup, and in 195 cases a HA coated hemispherical press fit cup was inserted. There were 189 women and 87 men aged 15-79 (mean 48) years. During follow-up, 14 patients died and 21 patients would not come for the follow-up examination as they were doing quite well with their prostheses. These patients were censored at their last control examination. This left 241 patients (287 hips) followed for 11 to 16 (mean 13) years after the operation.
RESULTS: During the follow-up period 48 press fit cups and 9 threaded cups were revised, none because of infection. Survival analyses indicated a cumulative survival of the threaded HA coated cup of 0.91 (95% CI: 0.86-0.97) at 16 years with one patient at risk. The cumulative survival of the HA coated press fit cup was 0.74 (0.69-0.80) at 15 years with no patient at risk. The difference is significant (P = 0.0002). Wear and age was significantly associated with revision (P < 0.0001 and 0.0002, respectively), and wear was significantly (P < 0.0001) associated with osteolysis.
CONCLUSION: These results indicate that HA coated threaded cups provide satisfactory bony interlock to resist force loads in the long run whereas the HA coated hemispherical press fit cups do not.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16799792     DOI: 10.1007/s00402-006-0176-8

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  11 in total

1.  Three-dimensional stress analysis of threaded cups - a finite element analysis.

Authors:  U Witzel; W Rieger; H Effenberger
Journal:  Int Orthop       Date:  2007-02-21       Impact factor: 3.075

2.  Long-term results of the Wagner conical screw cup.

Authors:  Alexander Schuh; Annemarie Schraml; Gerd Hohenberger
Journal:  Int Orthop       Date:  2008-06-26       Impact factor: 3.075

3.  [Five-year survival rate of the Allofit titanium press-fit cup].

Authors:  K Schroeder; A Moehlenbruch; M Zimmermann-Stenzel; D Parsch
Journal:  Orthopade       Date:  2010-01       Impact factor: 1.087

4.  THA with the ABG I prosthesis at 15 years. Excellent survival with minimal osteolysis.

Authors:  P N Baker; I A McMurtry; G Chuter; A Port; J Anderson
Journal:  Clin Orthop Relat Res       Date:  2010-07       Impact factor: 4.176

5.  The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Authors:  Chang-Dong Han; Keun-Young Shin; Hyun-Hee Lee; Kwan-Kyu Park; Ick-Hwan Yang; Woo-Suk Lee
Journal:  Hip Pelvis       Date:  2015-12-30

6.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

7.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

8.  Femoral shortening in total hip arthroplasty for high developmental dysplasia of the hip.

Authors:  Olav Reikerås; Jarl Erik Haaland; Paul Lereim
Journal:  Clin Orthop Relat Res       Date:  2010-01-14       Impact factor: 4.176

9.  Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years.

Authors:  Maiken Stilling; Ole Rahbek; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2009-03-28       Impact factor: 4.176

10.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

View more