Literature DB >> 12934215

The ABG hydroxyapatite-coated hip prosthesis: one hundred consecutive operations with average 6-year follow-up.

A Rogers1, R Kulkarni, E M Downes.   

Abstract

One hundred consecutive ABG (Anatomique Benoist Giraud, Howmedica) hydroxyapatite-coated hip arthroplasties in 97 patients were evaluated prospectively with a follow-up time of 4 to 10 years (mean, 6 years). Clinical results were excellent with an improvement in the Merle d'Aubigne score from 9 preoperatively to 17.4 at 5 years. Thigh pain was persistent in only 3%; it was mild in nature and controlled with simple analgesics. Kaplan-Meyer survivorship analysis was 100% for the femoral stem and 95% for the acetabular cup at 6 years. Of concern was the high polyethylene wear measured with an average of 0.24 mm/y (range, 0.05-0.76 mm/y).

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12934215     DOI: 10.1016/s0883-5403(03)00208-0

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

1.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

2.  Ten-year follow-up of an anatomical hydroxyapatite-coated total hip prosthesis.

Authors:  V Canales Cortés; J J Panisello Sebastiá; A Herrera Rodríguez; A Peguero Bona; A Martínez Martín; L Herrero Barcos; L García-Dihinx
Journal:  Int Orthop       Date:  2006-02-28       Impact factor: 3.075

3.  Early polyethylene wear and excessive acetabular granuloma in an uncemented HA-coated total hip arthroplasty--midterm results of a prospective study.

Authors:  Jörg Axel Karl Ohnsorge; Jack Davis; Uwe Maus; Muharrem Saklak; Markus Weisskopf; Dieter Christian Wirtz
Journal:  HSS J       Date:  2006-09

4.  THA with the ABG I prosthesis at 15 years. Excellent survival with minimal osteolysis.

Authors:  P N Baker; I A McMurtry; G Chuter; A Port; J Anderson
Journal:  Clin Orthop Relat Res       Date:  2010-07       Impact factor: 4.176

5.  The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Authors:  Chang-Dong Han; Keun-Young Shin; Hyun-Hee Lee; Kwan-Kyu Park; Ick-Hwan Yang; Woo-Suk Lee
Journal:  Hip Pelvis       Date:  2015-12-30

6.  Periprosthetic bone loss after insertion of an uncemented, customized femoral stem and an uncemented anatomical stem. A randomized DXA study with 5-year follow-up.

Authors:  Mona Nysted; Pål Benum; Jomar Klaksvik; Olav Foss; Arild Aamodt
Journal:  Acta Orthop       Date:  2011-06-14       Impact factor: 3.717

Review 7.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

8.  Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis.

Authors:  Takaki Miyagawa; Kazu Matsumoto; Shingo Komura; Haruhiko Akiyama
Journal:  BMC Musculoskelet Disord       Date:  2021-03-26       Impact factor: 2.362

Review 9.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

10.  Small and similar amounts of micromotion in an anatomical stem and a customized cementless femoral stem in regular-shaped femurs. A 5-year follow-up randomized RSA study.

Authors:  Mona Nysted; Olav A Foss; Jomar Klaksvik; Pål Benum; Kristin Haugan; Otto Schnell Husby; Arild Aamodt
Journal:  Acta Orthop       Date:  2014-04       Impact factor: 3.717

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.