Literature DB >> 12143977

HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2-8 years after implantation.

Magne Røkkum1, Astor Reigstad, Carina B Johansson.   

Abstract

20 hip arthroplasties with a Landos Corail Ti6Al4V stem entirely plasma-sprayed with a 155+/-35 microm thick HA coating were reoperated on after median 6 (2-8) years because of polyethylene wear (10), acetabular loosening (7), instability (2), or infection (1). We took biopsies from the proximal femurs adjacent to the well-fixed stems. Undecalcifled sections were prepared and examined with a light microscope. The biopsies contained median 5 (1.3-16 ) mm metal interface with 54% HA, 32% bone, and 14% soft tissue. The median thickness of the remaining HA coating was 137 (6-380) microm, and the HA-tissue interface included 89% bone and 11% soft tissue. All HA coatings showed partial degradation and replacement by soft tissue, osteoid-like tissue, or bone. 6 hips had tissue ingrowth between HA and metal consistent with delamination. 14 hips showed bone resorptive areas containing some HA particles and large amounts of polyethylene and metal particles, partly internalized in multinucleated giant cells and macrophages. Bone resorption was associated with metal and polyethylene particles, but not with HA particles. The HA coatings were undermined, resulting in release of large flakes of HA with free access to the articulation. We believe this mechanism may be responsible for third-body wear.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12143977     DOI: 10.1080/000164702320155293

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  14 in total

1.  Enhanced osteointegration of orthopaedic implant gradient coating composed of bioactive glass and nanohydroxyapatite.

Authors:  Xin-Hui Xie; Xiao-Wei Yu; Shao-Xian Zeng; Rui-Lin Du; Yu-Huai Hu; Zhen Yuan; Er-Yi Lu; Ke-Rong Dai; Ting-Ting Tang
Journal:  J Mater Sci Mater Med       Date:  2010-04-09       Impact factor: 3.896

2.  Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up.

Authors:  Alexander M Kress; Rainer Schmidt; Ulrich Holzwarth; Raimund Forst; Lutz A Mueller
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

3.  Is there any difference between tapered titanium stems with similar geometry and hydroxyapatite coating?

Authors:  G Cinotti; G Mazzotta; F Romana Ripani; G La Torre; G Giannicola
Journal:  Musculoskelet Surg       Date:  2019-01-08

4.  High prevalence of adverse reactions to metal debris in small-headed ASR™ hips.

Authors:  Aleksi Reito; Timo Puolakka; Petra Elo; Jorma Pajamäki; Antti Eskelinen
Journal:  Clin Orthop Relat Res       Date:  2013-04-30       Impact factor: 4.176

5.  The Salto total ankle arthroplasty: survivorship and analysis of failures at 7 to 11 years.

Authors:  Michel Bonnin; Fabrice Gaudot; Jean-Raphael Laurent; Scott Ellis; Jean-Alain Colombier; Thierry Judet
Journal:  Clin Orthop Relat Res       Date:  2010-07-01       Impact factor: 4.176

6.  The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Authors:  Chang-Dong Han; Keun-Young Shin; Hyun-Hee Lee; Kwan-Kyu Park; Ick-Hwan Yang; Woo-Suk Lee
Journal:  Hip Pelvis       Date:  2015-12-30

7.  Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years.

Authors:  Maiken Stilling; Ole Rahbek; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2009-03-28       Impact factor: 4.176

8.  Is reverse hybrid hip replacement the solution?

Authors:  Einar Lindalen; Leif I Havelin; Lars Nordsletten; Eva Dybvik; Anne M Fenstad; Geir Hallan; Ove Furnes; Oystein Høvik; Stephan M Röhrl
Journal:  Acta Orthop       Date:  2011-10-17       Impact factor: 3.717

9.  The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation.

Authors:  Yonghong Duan; Shu Zhu; Fei Guo; Jinyu Zhu; Mao Li; Jie Ma; Qingsheng Zhu
Journal:  Arch Med Sci       Date:  2012-05-09       Impact factor: 3.318

10.  Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial.

Authors:  Einar Lindalen; Jon Dahl; Lars Nordsletten; Finnur Snorrason; Øystein Høvik; Stephan Röhrl
Journal:  Acta Orthop       Date:  2012-11-01       Impact factor: 3.717