Literature DB >> 27377528

Radiation Dose and Image Quality in Pediatric Cardiac Computed Tomography: A Comparison Between Sequential and Third-Generation Dual-Source High-Pitch Spiral Techniques.

Huiliang Koh1, Ching Ching Ong1, Yun Song Choo1, Chong Ri Liang1, Grace Hui Zhen Tan1, Terence Chee Wen Lim2, Swee Chye Quek2, Shankar Sriram3, Lynette Li San Teo4.   

Abstract

The aim of this study was to investigate whether there is a reduction in radiation dose and improvement in image quality of pediatric cardiac computed tomography scans performed using the high-pitch spiral technique on a new third-generation dual-source 2 × 192-slice scanner (group B) compared with scans performed using the sequential technique on a single-source 256-slice scanner (group A). We performed a retrospective observational study on 40 patients aged ≤18 years who underwent prospectively electrocardiogram-triggered cardiac computed tomography. Image quality was assessed by pre-defined objective indices and a four-point subjective score. Apart from a higher mean heart rate in group A (P = 0.016), there were otherwise no significant inter-group differences in patient characteristics. The median effective dose was 4.41 mSv (interquartile range 2.58-5.90 mSv) in group A and 0.52 mSv (interquartile range 0.39-0.59 mSv) in group B (P < 0.001), representing a 88 % reduction. Subjective image quality score was significantly better in group B (4 = excellent with no artifact, mode 57.1 %) than in group A (3 = good with mild artifact, mode 57.9 %) (P < 0.001). Noise index, signal-to-noise ratio and contrast-to-noise ratio between both groups were not statistically significant. New third-generation dual-source high-pitch spiral scan technique can deliver excellent image quality with low radiation dose. Our results suggest that it should be considered as a first-choice technique for performing cardiac computed tomography in the pediatric population.

Entities:  

Keywords:  Computed tomography; Congenital heart disease; Image quality; Pediatrics; Radiation

Mesh:

Year:  2016        PMID: 27377528     DOI: 10.1007/s00246-016-1447-y

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  24 in total

Review 1.  Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration.

Authors:  Carolyn Young; Andrew M Taylor; Catherine M Owens
Journal:  Eur Radiol       Date:  2010-12-28       Impact factor: 5.315

2.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

3.  Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study.

Authors:  Jörg Hausleiter; Tanja S Meyer; Eugenio Martuscelli; Pietro Spagnolo; Hiroaki Yamamoto; Patricia Carrascosa; Thomas Anger; Lukas Lehmkuhl; Hatem Alkadhi; Stefan Martinoff; Martin Hadamitzky; Franziska Hein; Bernhard Bischoff; Miriam Kuse; Albert Schömig; Stephan Achenbach
Journal:  JACC Cardiovasc Imaging       Date:  2012-05

4.  Radiation dose reduction in pediatric cardiac computed tomography: experience from a tertiary medical center.

Authors:  Brian B Ghoshhajra; Ashley M Lee; Leif-Christopher Engel; Csilla Celeng; Mannudeep K Kalra; Thomas J Brady; Udo Hoffmann; Sjirk J Westra; Suhny Abbara
Journal:  Pediatr Cardiol       Date:  2013-07-20       Impact factor: 1.655

Review 5.  Utility of Low-dose High-pitch Scanning for Pediatric Cardiac Computed Tomographic Imaging.

Authors:  Christopher M Long; Svati S Long; Pamela T Johnson; Mahadevappa Mahesh; Elliot K Fishman; Stefan L Zimmerman
Journal:  J Thorac Imaging       Date:  2015-07       Impact factor: 3.000

6.  CT angiography of neonates and infants: comparison of radiation dose and image quality of target mode prospectively ECG-gated 320-MDCT and ungated helical 64-MDCT.

Authors:  Siddharth P Jadhav; Farahnaz Golriz; Lamya A Atweh; Wei Zhang; Rajesh Krishnamurthy
Journal:  AJR Am J Roentgenol       Date:  2015-02       Impact factor: 3.959

7.  Cardiovascular CT angiography in neonates and children: image quality and potential for radiation dose reduction with iterative image reconstruction techniques.

Authors:  Francesco Tricarico; Anthony M Hlavacek; U Joseph Schoepf; Ullrich Ebersberger; John W Nance; Rozemarijn Vliegenthart; Young Jun Cho; J Reid Spears; Francesco Secchi; Giancarlo Savino; Riccardo Marano; Stefan O Schoenberg; Lorenzo Bonomo; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2012-12-04       Impact factor: 5.315

8.  ECG-synchronized CT angiography in 324 consecutive pediatric patients: spectrum of indications and trends in radiation dose.

Authors:  Felix G Meinel; Thomas Henzler; U Joseph Schoepf; Patsy W Park; Walter Huda; James V Spearman; Kevin T Dyer; Anil G Rao; Anthony M Hlavacek
Journal:  Pediatr Cardiol       Date:  2014-11-08       Impact factor: 1.655

9.  Accuracy, image quality, and radiation dose of prospectively ECG-triggered high-pitch dual-source CT angiography in infants and children with complex coarctation of the aorta.

Authors:  Jian Xu; Hongliang Zhao; Xiaoying Wang; Yuxiang Bai; Liwen Liu; Ying Liu; Mengqi Wei; Jian Li; Minwen Zheng
Journal:  Acad Radiol       Date:  2014-08-02       Impact factor: 3.173

10.  Total anomalous pulmonary venous connection in a neonate characterised by low-dose, high-pitch cardiac CT.

Authors:  Swati Deshmukh; W Reid Thompson; Stefan L Zimmerman
Journal:  Cardiol Young       Date:  2014-07-24       Impact factor: 1.093

View more
  2 in total

1.  The feasibility of high-pitch acquisition protocol for imaging of the pediatric abdomen by dual-source CT.

Authors:  Eray Atlı; Erhan Akpınar; Emre Ünal; Berna Oğuz Sayan; Mithat Haliloğlu
Journal:  Jpn J Radiol       Date:  2018-05-28       Impact factor: 2.374

Review 2.  A multi-disciplinary, comprehensive approach to management of children with heterotaxy.

Authors:  Thomas G Saba; Gabrielle C Geddes; Stephanie M Ware; David N Schidlow; Pedro J Del Nido; Nathan S Rubalcava; Samir K Gadepalli; Terri Stillwell; Anne Griffiths; Laura M Bennett Murphy; Andrew T Barber; Margaret W Leigh; Necia Sabin; Adam J Shapiro
Journal:  Orphanet J Rare Dis       Date:  2022-09-09       Impact factor: 4.303

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.