Literature DB >> 23207869

Cardiovascular CT angiography in neonates and children: image quality and potential for radiation dose reduction with iterative image reconstruction techniques.

Francesco Tricarico1, Anthony M Hlavacek, U Joseph Schoepf, Ullrich Ebersberger, John W Nance, Rozemarijn Vliegenthart, Young Jun Cho, J Reid Spears, Francesco Secchi, Giancarlo Savino, Riccardo Marano, Stefan O Schoenberg, Lorenzo Bonomo, Paul Apfaltrer.   

Abstract

OBJECTIVES: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions.
METHODS: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated.
RESULTS: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv.
CONCLUSIONS: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. KEY POINTS: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.

Entities:  

Mesh:

Year:  2012        PMID: 23207869     DOI: 10.1007/s00330-012-2734-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  38 in total

1.  Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Ravi S Kamath; Elkan F Halpern; Sanjay Saini
Journal:  Radiology       Date:  2004-08       Impact factor: 11.105

2.  Detection of pulmonary arterial morphology in tetralogy of Fallot with pulmonary atresia by computed tomography: 12 years of experience.

Authors:  Ming-Tai Lin; Jou-Kou Wang; Yih-Sharng Chen; Wen-Jeng Lee; Hsin-Hui Chiu; Chun-An Chen; Shuenn-Nan Chiu; En-Ting Wu; Chun-Wei Lu; Shu-Chien Huang; Shyh-Jye Chen; Ing-Sh Chiu; Chung-I Chang; Mei-Hwan Wu
Journal:  Eur J Pediatr       Date:  2011-11-15       Impact factor: 3.183

3.  Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation.

Authors:  Christopher Herzog; Denise M Mulvihill; Shaun A Nguyen; Giancarlo Savino; Bernhard Schmidt; Philip Costello; Thomas J Vogl; U Joseph Schoepf
Journal:  AJR Am J Roentgenol       Date:  2008-05       Impact factor: 3.959

4.  Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method.

Authors:  Karen E Thomas; Bo Wang
Journal:  Pediatr Radiol       Date:  2008-04-08

Review 5.  MRI for physiology and function: technical advances in MRI of congenital heart disease.

Authors:  J C Haselgrove; O Simonetti
Journal:  Semin Roentgenol       Date:  1998-07       Impact factor: 0.800

6.  Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: a phantom study.

Authors:  Shi-Ting Feng; Martin Wai-Ming Law; Bingsheng Huang; Sherry Ng; Zi-Ping Li; Quan-Fei Meng; Pek-Lan Khong
Journal:  Eur J Radiol       Date:  2010-04-03       Impact factor: 3.528

7.  Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience.

Authors:  Márcio Sommer Bittencourt; Bernhard Schmidt; Martin Seltmann; Gerd Muschiol; Dieter Ropers; Werner Günther Daniel; Stephan Achenbach
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-01       Impact factor: 2.357

8.  CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT.

Authors:  Alban Gervaise; Benoît Osemont; Sophie Lecocq; Alain Noel; Emilien Micard; Jacques Felblinger; Alain Blum
Journal:  Eur Radiol       Date:  2011-09-17       Impact factor: 5.315

9.  Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality.

Authors:  Gregor Pache; Jochen Grohmann; Stefan Bulla; Raoul Arnold; Brigitte Stiller; Christian Schlensak; Mathias Langer; Philipp Blanke
Journal:  Eur J Radiol       Date:  2011-02-09       Impact factor: 3.528

10.  Reducing radiation exposure from survey CT scans.

Authors:  Jennifer C O'Daniel; Donna M Stevens; Dianna D Cody
Journal:  AJR Am J Roentgenol       Date:  2005-08       Impact factor: 3.959

View more
  27 in total

1.  Image quality and dose optimisation for infant CT using a paediatric phantom.

Authors:  Jack W Lambert; Andrew S Phelps; Jesse L Courtier; Robert G Gould; John D MacKenzie
Journal:  Eur Radiol       Date:  2015-08-26       Impact factor: 5.315

2.  Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography.

Authors:  Lin Yang; Jian Zhuang; Meiping Huang; Changhong Liang; Hui Liu
Journal:  Pediatr Radiol       Date:  2016-09-16

3.  Quantitative evaluation of coronary artery visibility on CT angiography in Kawasaki disease: young vs. old children.

Authors:  Hyun Woo Goo
Journal:  Int J Cardiovasc Imaging       Date:  2020-10-12       Impact factor: 2.357

4.  Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction.

Authors:  Wei-Hua Yin; Bin Lu; Zhi-Hui Hou; Nan Li; Lei Han; Yong-Jian Wu; Hong-Xia Niu; Justin R Silverman; Carlo Nicola De Cecco; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2013-06-27       Impact factor: 5.315

5.  Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children - comparison with full-dose CT with filtered back projection.

Authors:  Minwook Lee; Myung-Joon Kim; Kyung Hwa Han; Mi-Jung Lee
Journal:  Pediatr Radiol       Date:  2014-07-17

6.  Reducing radiation dose without compromising image quality in preoperative perforator flap imaging with CTA using ASIR technology.

Authors:  Vachara Niumsawatt; Andrew N Debrotwir; Warren Matthew Rozen
Journal:  Int Surg       Date:  2014 Jul-Aug

Review 7.  The role of advanced reconstruction algorithms in cardiac CT.

Authors:  Sandra S Halliburton; Yuki Tanabe; Sasan Partovi; Prabhakar Rajiah
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

8.  ECG-synchronized CT angiography in 324 consecutive pediatric patients: spectrum of indications and trends in radiation dose.

Authors:  Felix G Meinel; Thomas Henzler; U Joseph Schoepf; Patsy W Park; Walter Huda; James V Spearman; Kevin T Dyer; Anil G Rao; Anthony M Hlavacek
Journal:  Pediatr Cardiol       Date:  2014-11-08       Impact factor: 1.655

Review 9.  Imaging Modalities in Congenital Heart Disease.

Authors:  Sakshi Sachdeva; Saurabh Kumar Gupta
Journal:  Indian J Pediatr       Date:  2020-04-13       Impact factor: 1.967

10.  Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison.

Authors:  Aleksander W Krazinski; Felix G Meinel; U Joseph Schoepf; Justin R Silverman; Christian Canstein; Carlo N De Cecco; Lucas L Geyer
Journal:  Eur Radiol       Date:  2014-07-24       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.