Literature DB >> 23872908

Radiation dose reduction in pediatric cardiac computed tomography: experience from a tertiary medical center.

Brian B Ghoshhajra1, Ashley M Lee, Leif-Christopher Engel, Csilla Celeng, Mannudeep K Kalra, Thomas J Brady, Udo Hoffmann, Sjirk J Westra, Suhny Abbara.   

Abstract

Cardiac CT angiography (cCTA) has become an established method for the assessment of congenital heart disease. However, the potential harmful effects of ionizing radiation must be considered, particularly in younger, more radiosensitive patients. In this study, we sought to assess the temporal change in radiation doses from pediatric cCTA during an 8-year period at a tertiary medical center. This retrospective study included all patients ≤18 years old who were referred to electrocardiography (ECG)-gated cCTA for the assessment of congenital heart disease or inflammatory disease (Kawasaki disease) from November 2004 to September 2012. During the study period, 95 patients were scanned using 3 different scanner models-64-slice multidetector CT (64-MDCT) and first- (64-DSCT) and second-generation (128-DSCT) dual-source CT-and 3 scan protocols-retrospective ECG-gated helical scanning (RG), prospective ECG-triggered axial scanning (PT), or prospective ECG-triggered high-pitch helical scanning (HPH). Effective dose (ED) was calculated with the dose length product method with a conversion factor (k) adjusted for age. ED was then compared among scan protocols. Image quality was extracted from clinical cCTA reports when available. Overall, 94 % of scans were diagnostic (80 % for 64-slice MDCT, 93 % for 64-slice DSCT, and 97 % for 128-slice DSCT).With 128-DSCT, median ED (1.0 [range 0.6-2.0] mSv) decreased by 85.8 % and 66.8 % compared with 64-MDCT (6.8 [range 2.9-13.6] mSv) and 64-DSCT (2.9 [range 0.9-4.1] mSv), respectively. With HPH, median ED (0.9 [range 0.6-1.8] mSv) decreased by 59.4 % and 85.4 % compared with PT (2.2 [range 0.9-3.4] mSv) and RG (6.1 [range 2.5-10.6] mSv). cCTA can now be obtained at very low radiation doses in pediatric patients using the latest dual-source CT technology in combination with prospective ECG-triggered HPH acquisition.

Entities:  

Mesh:

Year:  2013        PMID: 23872908     DOI: 10.1007/s00246-013-0758-5

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  51 in total

1.  A call to "image gently".

Authors:  Dana Etzel-Hardman
Journal:  J Pediatr Nurs       Date:  2012-05-17       Impact factor: 2.145

2.  Image Gently pediatric digital radiography summit: executive summary.

Authors:  Steven Don; Marilyn J Goske; Susan John; Bruce Whiting; Charles E Willis
Journal:  Pediatr Radiol       Date:  2011-01-21

3.  Size-specific dose estimation for CT: how should it be used and what does it mean?

Authors:  James A Brink; Richard L Morin
Journal:  Radiology       Date:  2012-12       Impact factor: 11.105

Review 4.  Cardiac CT angiography in children with congenital heart disease.

Authors:  Suvipaporn Siripornpitak; Ratanaporn Pornkul; Pongsak Khowsathit; Thanarat Layangool; Worakan Promphan; Boonchob Pongpanich
Journal:  Eur J Radiol       Date:  2011-12-22       Impact factor: 3.528

5.  Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease.

Authors:  B Kelly Han; Jana Lindberg; Katharine Grant; Robert S Schwartz; John R Lesser
Journal:  Am J Cardiol       Date:  2011-05-15       Impact factor: 2.778

Review 6.  Image Gently: progress and challenges in CT education and advocacy.

Authors:  Marilyn J Goske; Kimberly E Applegate; Dorothy Bulas; Priscilla F Butler; Michael J Callahan; Brian D Coley; Steven Don; Donald P Frush; Marta Hernanz-Schulman; Sue C Kaste; Gregory Morrison; Manrita Sidhu; Keith J Strauss; S Ted Treves
Journal:  Pediatr Radiol       Date:  2011-08-17

7.  Coronary computed tomography angiography during arrhythmia: Radiation dose reduction with prospectively ECG-triggered axial and retrospectively ECG-gated helical 128-slice dual-source CT.

Authors:  Ashley M Lee; Leif-Christopher Engel; Baiju Shah; Gary Liew; Manavjot S Sidhu; Mannudeep Kalra; Suhny Abbara; Thomas J Brady; Udo Hoffmann; Brian B Ghoshhajra
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-04-07

8.  Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality.

Authors:  Brian B Ghoshhajra; Leif-Christopher Engel; Mihály Károlyi; Manavjot Singh Sidhu; Bryan Wai; Mitya Barreto; Uthamalingam Shanmugam; Udo Hoffmann; Thomas J Brady; Manudeep Kalra; Suhny Abbara
Journal:  J Thorac Imaging       Date:  2013-01       Impact factor: 3.000

9.  Surface area in children: a simple formula.

Authors:  Muhammad Furqan; Anwarul Haque
Journal:  Indian Pediatr       Date:  2009-04-01       Impact factor: 1.411

Review 10.  The role of cardiovascular magnetic resonance in pediatric congenital heart disease.

Authors:  Hopewell N Ntsinjana; Marina L Hughes; Andrew M Taylor
Journal:  J Cardiovasc Magn Reson       Date:  2011-09-21       Impact factor: 5.364

View more
  18 in total

1.  Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

Authors:  Oliver Rompel; Martin Glöckler; Rolf Janka; Sven Dittrich; Robert Cesnjevar; Michael M Lell; Michael Uder; Matthias Hammon
Journal:  Pediatr Radiol       Date:  2016-01-06

Review 2.  Update on the Role of Cardiac Magnetic Resonance Imaging in Congenital Heart Disease.

Authors:  Prabhakar Rajiah; Animesh Tandon; Gerald F Greil; Suhny Abbara
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-01

3.  Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD).

Authors:  Peter K T Hui; Hyun Woo Goo; Jing Du; Janice J K Ip; Suzu Kanzaki; Young Jin Kim; Supika Kritsaneepaiboon; Oktavia Lilyasari; Suvipaporn Siripornpitak
Journal:  Pediatr Radiol       Date:  2017-04-24

4.  Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality.

Authors:  Bouchra Habib Geryes; Raphael Calmon; Diala Khraiche; Nathalie Boddaert; Damien Bonnet; Francesca Raimondi
Journal:  Eur Radiol       Date:  2015-10-03       Impact factor: 5.315

Review 5.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

Review 6.  Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign.

Authors:  Cynthia K Rigsby; Sarah E McKenney; Kevin D Hill; Anjali Chelliah; Andrew J Einstein; B Kelly Han; Joshua D Robinson; Christina L Sammet; Timothy C Slesnick; Donald P Frush
Journal:  Pediatr Radiol       Date:  2018-01-01

7.  Assessment of coronary artery by prospective ECG-triggered 256 multi-slice CT on children with congenital heart disease.

Authors:  Li-Ping Yao; Li Zhang; Hui-Ming Li; Ming Ding; Ling-Wei Yu; Xin Yang; Xiao-Ming Li; Kun Sun
Journal:  Int J Cardiovasc Imaging       Date:  2017-05-18       Impact factor: 2.357

8.  ECG-synchronized CT angiography in 324 consecutive pediatric patients: spectrum of indications and trends in radiation dose.

Authors:  Felix G Meinel; Thomas Henzler; U Joseph Schoepf; Patsy W Park; Walter Huda; James V Spearman; Kevin T Dyer; Anil G Rao; Anthony M Hlavacek
Journal:  Pediatr Cardiol       Date:  2014-11-08       Impact factor: 1.655

Review 9.  D-transposition of the great arteries: the current era of the arterial switch operation.

Authors:  Juan Villafañe; M Regina Lantin-Hermoso; Ami B Bhatt; James S Tweddell; Tal Geva; Meena Nathan; Martin J Elliott; Victoria L Vetter; Stephen M Paridon; Lazaros Kochilas; Kathy J Jenkins; Robert H Beekman; Gil Wernovsky; Jeffrey A Towbin
Journal:  J Am Coll Cardiol       Date:  2014-08-05       Impact factor: 24.094

10.  Radiation Dose and Image Quality in Pediatric Cardiac Computed Tomography: A Comparison Between Sequential and Third-Generation Dual-Source High-Pitch Spiral Techniques.

Authors:  Huiliang Koh; Ching Ching Ong; Yun Song Choo; Chong Ri Liang; Grace Hui Zhen Tan; Terence Chee Wen Lim; Swee Chye Quek; Shankar Sriram; Lynette Li San Teo
Journal:  Pediatr Cardiol       Date:  2016-07-05       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.