In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method.

J Brückel1, W Kerner, H Zier, G Steinbach, E F Pfeiffer.   

Abstract

An amperometric enzyme electrode and a wick technique were used for measurement of glucose in sc. tissue of sheep. When wicks were left implanted long enough to equilibrate with interstitial fluid, sc. glucose could have been reproducibly determined with the necessary accuracy. It was demonstrated that sc. tissue glucose concentrations in sheep are about 30% higher than in whole blood and are on the level of plasma glucose. This allows interpretation of sc. glucose sensor currents since results of in vitro-calibrations cannot be transferred to in vivo conditions. When an enzymatic sensor was implanted in the sc. compartment, the sensor signals were closely related to changes of blood glucose. These in vivo experiments indicate that short term glucose-monitoring with an subcutaneously implantable glucose sensor is feasible and so may provide a possible access to glycemic control. Further experiments will have to show, if glucose-controlled insulin infusions based on the output of a sc. glucose sensor will be able to maintain stable normoglycemia.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2733378     DOI: 10.1007/bf01721675

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  13 in total

1.  Changes in the interstitial fluid and the muscle water in rabbits in hemorrhagic shock.

Authors:  M W Wolcott; T I Malinin; N M Wu
Journal:  Ann Surg       Date:  1976-12       Impact factor: 12.969

2.  A potentially implantable enzyme electrode for amperometric measurement of glucose.

Authors:  W Kerner; H Zier; G Steinbach; J Brückel; E F Pfeiffer; T Weiss; K Cammann; H Planck
Journal:  Horm Metab Res Suppl       Date:  1988

3.  The artificial beta cell--a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system).

Authors:  E F Pfeiffer; C Thum; A H Clemens
Journal:  Horm Metab Res       Date:  1974-09       Impact factor: 2.936

Review 4.  Interstitial fluid pressure.

Authors:  A C Guyton; H J Granger; A E Taylor
Journal:  Physiol Rev       Date:  1971-07       Impact factor: 37.312

5.  Wearable artificial endocrine pancrease with needle-type glucose sensor.

Authors:  M Shichiri; R Kawamori; Y Yamasaki; N Hakui; H Abe
Journal:  Lancet       Date:  1982-11-20       Impact factor: 79.321

6.  A new glucose electrode for tissue measurements.

Authors:  M Kessler; J Höper; H J Volkholz; D Sailer; L Demling
Journal:  Hepatogastroenterology       Date:  1984-12

7.  Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: evaluation of the method.

Authors:  H Noddeland
Journal:  Scand J Clin Lab Invest       Date:  1982-04       Impact factor: 1.713

8.  Glycosylated hemoglobin in human and animal red cells. Role of glucose permeability.

Authors:  P J Higgins; R L Garlick; H F Bunn
Journal:  Diabetes       Date:  1982-09       Impact factor: 9.461

9.  Glucose concentration at possible sensor tissue implant sites.

Authors:  S K Wolfson; J F Tokarsky; S J Yao; M A Krupper
Journal:  Diabetes Care       Date:  1982 May-Jun       Impact factor: 19.112

Review 10.  Diabetes mellitus: biosensors for research and management.

Authors:  A P Turner; J C Pickup
Journal:  Biosensors       Date:  1985
View more
  5 in total

Review 1.  Does fall in tissue glucose precede fall in blood glucose?

Authors:  F Sternberg; C Meyerhoff; F J Mennel; H Mayer; F Bischof; E F Pfeiffer
Journal:  Diabetologia       Date:  1996-05       Impact factor: 10.122

Review 2.  [Normoglycemia as a therapy goal in diabetes treatment--concept and realization].

Authors:  E G Siegel
Journal:  Klin Wochenschr       Date:  1990-03-16

3.  Comments on subcutaneous glucose monitoring.

Authors:  F Sternberg; C Meyerhoff; F J Mennel; F Bischof; H Mayer; E F Pfeiffer
Journal:  Diabetologia       Date:  1994-05       Impact factor: 10.122

4.  On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis.

Authors:  C Meyerhoff; F Bischof; F Sternberg; H Zier; E F Pfeiffer
Journal:  Diabetologia       Date:  1992-11       Impact factor: 10.122

5.  Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man.

Authors:  J C Pickup; D J Claremont; G W Shaw
Journal:  Acta Diabetol       Date:  1993       Impact factor: 4.280

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.