Literature DB >> 8739922

Does fall in tissue glucose precede fall in blood glucose?

F Sternberg1, C Meyerhoff, F J Mennel, H Mayer, F Bischof, E F Pfeiffer.   

Abstract

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8739922     DOI: 10.1007/bf00403309

Source DB:  PubMed          Journal:  Diabetologia        ISSN: 0012-186X            Impact factor:   10.122


× No keyword cloud information.
  20 in total

1.  Calibration of a wearable glucose sensor.

Authors:  F J Schmidt; A L Aalders; A J Schoonen; H Doorenbos
Journal:  Int J Artif Organs       Date:  1992-01       Impact factor: 1.595

2.  Comments on subcutaneous glucose monitoring.

Authors:  F Sternberg; C Meyerhoff; F J Mennel; F Bischof; H Mayer; E F Pfeiffer
Journal:  Diabetologia       Date:  1994-05       Impact factor: 10.122

3.  Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell.

Authors:  P Abel; A Müller; U Fischer
Journal:  Biomed Biochim Acta       Date:  1984

4.  Epidemiology of severe hypoglycemia in the diabetes control and complications trial. The DCCT Research Group.

Authors: 
Journal:  Am J Med       Date:  1991-04       Impact factor: 4.965

5.  the "Ulm Zucker Uhr System" and its consequences.

Authors:  E F Pfeiffer
Journal:  Horm Metab Res       Date:  1994-11       Impact factor: 2.936

6.  On the way to the automated (blood) glucose regulation in diabetes: the dark past, the grey present and the rosy future. XII Congress of the International Diabetes Federation, Madrid, 22-28 September 1985.

Authors:  E F Pfeiffer
Journal:  Diabetologia       Date:  1987-02       Impact factor: 10.122

7.  Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue.

Authors:  D Moatti-Sirat; F Capron; V Poitout; G Reach; D S Bindra; Y Zhang; G S Wilson; D R Thévenot
Journal:  Diabetologia       Date:  1992-03       Impact factor: 10.122

Review 8.  Banting Lecture. Hypoglycemia: the limiting factor in the management of IDDM.

Authors:  P E Cryer
Journal:  Diabetes       Date:  1994-11       Impact factor: 9.461

9.  Hierarchy of glycemic thresholds for counterregulatory hormone secretion, symptoms, and cerebral dysfunction.

Authors:  A Mitrakou; C Ryan; T Veneman; M Mokan; T Jenssen; I Kiss; J Durrant; P Cryer; J Gerich
Journal:  Am J Physiol       Date:  1991-01

10.  Severe hypoglycemia in diabetic patients: frequency, causes, prevention.

Authors:  A F Casparie; L D Elving
Journal:  Diabetes Care       Date:  1985 Mar-Apr       Impact factor: 19.112

View more
  28 in total

1.  In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring. Interview by Judy Jones.

Authors:  J Pickup; O Rolinski; D Birch
Journal:  BMJ       Date:  1999-11-13

2.  Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.

Authors:  Raymond J Davey; Timothy W Jones; Paul A Fournier
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  Modeling Plasma-to-Interstitium Glucose Kinetics from Multitracer Plasma and Microdialysis Data.

Authors:  Michele Schiavon; Chiara Dalla Man; Simmi Dube; Michael Slama; Yogish C Kudva; Thomas Peyser; Ananda Basu; Rita Basu; Claudio Cobelli
Journal:  Diabetes Technol Ther       Date:  2015-08-27       Impact factor: 6.118

Review 4.  A tale of two compartments: interstitial versus blood glucose monitoring.

Authors:  Eda Cengiz; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

5.  Real-time continuous glucose monitoring in the clinical setting: the good, the bad, and the practical.

Authors:  Irene Mamkin; Svetlana Ten; Sonal Bhandari; Neesha Ramchandani
Journal:  J Diabetes Sci Technol       Date:  2008-09

6.  Differences in Glucose Levels Between Left and Right Arm.

Authors:  Xiaohan Liu; Sachin A Shah; Tony J Eid; Allen Shek
Journal:  J Diabetes Sci Technol       Date:  2019-05-21

7.  Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

Authors:  Cosimo Scuffi; Fausto Lucarelli; Francesco Valgimigli
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

8.  Continuous Glucose Monitoring After Gastric Bypass to Evaluate the Glucose Variability After a Low-Carbohydrate Diet and to Determine Hypoglycemia.

Authors:  Joan Bach Nielsen; Caroline Bruun Abild; Ane Mathilde Pedersen; Steen Bønløkke Pedersen; Bjørn Richelsen
Journal:  Obes Surg       Date:  2016-09       Impact factor: 4.129

Review 9.  Can glucose be monitored accurately at the site of subcutaneous insulin delivery?

Authors:  W Kenneth Ward; Jessica R Castle; Peter G Jacobs; Robert S Cargill
Journal:  J Diabetes Sci Technol       Date:  2014-02-18

10.  Putative delays in interstitial fluid (ISF) glucose kinetics can be attributed to the glucose sensing systems used to measure them rather than the delay in ISF glucose itself.

Authors:  Gayane Voskanyan; D Barry Keenan; John J Mastrototaro; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2007-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.