Literature DB >> 7134796

Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: evaluation of the method.

H Noddeland.   

Abstract

Interstitial fluid was collected from human subcutaneous tissue by implantation of multifilamentous nylon wicks on the side of thorax. The skin was anaesthetized by a small injection of lidocaine. Direct measurement of colloid osmotic pressure in a control group of 20 healthy volunteers gave a mean of 15.8 (SD 2.3) mmHg in wick fluid and 26.9 (SD 4.1) mmHg in serum samples. Standard deviation of the method for wick fluid samples was 1.2 mmHg. Significant blood contamination occurred in less than 20% of the wicks. Fluid content in wicks varied within narrow limits independent of its colloid osmotic pressure. The dynamics of wick fluid protein uptake was studied by uptake of 131I albumin from plasma, and by measurement of colloid osmotic pressure after 30, 60, 120 and 180 min of implantation. The results showed an initial rapid uptake from plasma of a major part of the wick fluid proteins within 30 min. After 120 min wick fluid colloid osmotic pressure reached the same level whether the wicks were 'primed' with serum proteins or not. Altogether these observations support the view that wick fluid reflects interstitial tissue fluid with respect to colloid osmotic pressure when the wicks are implanted for 60 min.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7134796

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  8 in total

1.  In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method.

Authors:  J Brückel; W Kerner; H Zier; G Steinbach; E F Pfeiffer
Journal:  Klin Wochenschr       Date:  1989-05-02

2.  Time-related changes in the Starling forces following extracorporeal circulation.

Authors:  K A Rein; R Stenseth; H O Myhre; O W Levang; S Kahn
Journal:  Cardiovasc Drugs Ther       Date:  1988-11       Impact factor: 3.727

3.  Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs.

Authors:  U Fischer; R Ertle; P Abel; K Rebrin; E Brunstein; H Hahn von Dorsche; E J Freyse
Journal:  Diabetologia       Date:  1987-12       Impact factor: 10.122

4.  Transcapillary colloid osmotic gradient, plasma volume and interstitial fluid volume in long-term type 1 (insulin-dependent) diabetes.

Authors:  P Fauchald; J Norseth; J Jervell
Journal:  Diabetologia       Date:  1985-05       Impact factor: 10.122

5.  Capillary leakage in post-cardiac arrest survivors during therapeutic hypothermia - a prospective, randomised study.

Authors:  Bård E Heradstveit; Anne Berit Guttormsen; Jørund Langørgen; Stig-Morten Hammersborg; Tore Wentzel-Larsen; Rune Fanebust; Elna-Marie Larsson; Jon-Kenneth Heltne
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2010-05-25       Impact factor: 2.953

6.  Effect of topical anaesthetics on interstitial colloid osmotic pressure in human subcutaneous tissue sampled by wick technique.

Authors:  Hans Jørgen Timm Guthe; Torbjørn Nedrebø; Olav Tenstad; Helge Wiig; Ansgar Berg
Journal:  PLoS One       Date:  2012-02-14       Impact factor: 3.240

7.  Interstitial fluid colloid osmotic pressure in healthy children.

Authors:  Hans Jørgen Timm Guthe; Marianne Indrebø; Torbjørn Nedrebø; Gunnar Norgård; Helge Wiig; Ansgar Berg
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

8.  Transcapillary fluid flux and inflammatory response during neonatal therapeutic hypothermia: an open, longitudinal, observational study.

Authors:  Hans Jørgen Timm Guthe; Torbjørn Nedrebø; Jan Kristian Damås; Helge Wiig; Ansgar Berg
Journal:  BMC Pediatr       Date:  2018-02-23       Impact factor: 2.125

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.