Wearable artificial endocrine pancrease with needle-type glucose sensor.

M Shichiri, R Kawamori, Y Yamasaki, N Hakui, H Abe.   

Abstract

Miniaturisation of the bedside artificial endocrine pancreas in necessary to provide a means of restoring physiological glycaemic excursions in diabetic patients in the long term. One of the remaining problems in producing such a sophisticated device is the difficulty in developing a sufficiently small glucose-monitoring system. A needle-type glucose sensor has been developed which is suitable for use in a closed-loop glycaemic control system. The wearable artificial endocrine pancreas, incorporating the needle-type glucose sensor, a computer calculating infusion rates of insulin, glucagon, or both, and infusion pumps, was tested in pancreatectomised dogs: the device produced perfect control of blood glucose for up to 7 days.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6128452     DOI: 10.1016/s0140-6736(82)92788-x

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  45 in total

1.  In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring. Interview by Judy Jones.

Authors:  J Pickup; O Rolinski; D Birch
Journal:  BMJ       Date:  1999-11-13

Review 2.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  History of artificial organs in Japan.

Authors:  Kazuhiko Atsumi
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

Review 4.  Enzymatic biosensors.

Authors:  Jeffrey D Newman; Steven J Setford
Journal:  Mol Biotechnol       Date:  2006-03       Impact factor: 2.695

Review 5.  Role of Glucagon in Automated Insulin Delivery.

Authors:  Leah M Wilson; Peter G Jacobs; Jessica R Castle
Journal:  Endocrinol Metab Clin North Am       Date:  2019-12-10       Impact factor: 4.741

Review 6.  In vivo chemical sensors for intensive-care monitoring.

Authors:  P Rolfe
Journal:  Med Biol Eng Comput       Date:  1990-05       Impact factor: 2.602

Review 7.  Optimisation of enzyme electrodes.

Authors:  L X Tang; P Vadgama
Journal:  Med Biol Eng Comput       Date:  1990-05       Impact factor: 2.602

Review 8.  Biocompatibility issues of implantable drug delivery systems.

Authors:  H Park; K Park
Journal:  Pharm Res       Date:  1996-12       Impact factor: 4.200

Review 9.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

10.  A microelectrode for continuous monitoring of glucose concentration in isolated perfused tubule segments.

Authors:  W Rehwald; J Geibel; E Gstrein; H Oberleithner
Journal:  Pflugers Arch       Date:  1984-04       Impact factor: 3.657

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.