Literature DB >> 1473620

On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis.

C Meyerhoff1, F Bischof, F Sternberg, H Zier, E F Pfeiffer.   

Abstract

For the normalisation of blood glucose levels in diabetic patients by feedback controlled insulin delivery, a self-manageable and reliable method for continuous glucose estimation is still not available. By combining a commercially available needle type dialysis probe (molecular cutoff 20,000 Da) with a sensitive glucose sensor, we obtained a device for continuous glucose measurement in dialysate. This device was tested in healthy volunteers during a 75-g oral glucose tolerance test and in Type 2 (non-insulin-dependent) diabetic patients. Venous glucose and subcutaneous sensor signal were followed for 300 min (ten healthy subjects), 21 h (three healthy subjects) or 9 h (seven Type 2 diabetic patients). The recovery of the microdialysis was interindividually different, but after calibration, glucose levels in the dialysate and subcutaneous glucose sensor signal correlated well (r = 0.84-0.95). Under the assumption of a physiologic and technical delay between intravenous and subcutaneous glucose, correlation coefficient between intravenous glucose and subcutaneous sensor signal ranged from 0.60 to 0.93. We conclude that changes in blood glucose could be monitored in the subcutaneous tissue by the microdialysis technique in a continuous on line manner.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1473620     DOI: 10.1007/bf02221686

Source DB:  PubMed          Journal:  Diabetologia        ISSN: 0012-186X            Impact factor:   10.122


  18 in total

1.  On the enzymatic determination of blood glucose.

Authors:  E RAABO; T C TERKILDSEN
Journal:  Scand J Clin Lab Invest       Date:  1960       Impact factor: 1.713

Review 2.  Brain microdialysis.

Authors:  H Benveniste
Journal:  J Neurochem       Date:  1989-06       Impact factor: 5.372

3.  Progress in practical endocrinology. The Glucosensor Unitec Ulm--a portable monitor for continuous blood glucose measurement.

Authors:  J Brückel; H Zier; W Kerner; E F Pfeiffer
Journal:  Horm Metab Res       Date:  1990-07       Impact factor: 2.936

Review 4.  Microdialysis--a novel technique for clinical investigations.

Authors:  P Lönnroth; U Smith
Journal:  J Intern Med       Date:  1990-05       Impact factor: 8.989

5.  A potentially implantable enzyme electrode for amperometric measurement of glucose.

Authors:  W Kerner; H Zier; G Steinbach; J Brückel; E F Pfeiffer; T Weiss; K Cammann; H Planck
Journal:  Horm Metab Res Suppl       Date:  1988

6.  The artificial beta cell--a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system).

Authors:  E F Pfeiffer; C Thum; A H Clemens
Journal:  Horm Metab Res       Date:  1974-09       Impact factor: 2.936

7.  Dialytrode for long term intracerebral perfusion in awake monkeys.

Authors:  J M Delgado; F V DeFeudis; R H Roth; D K Ryugo; B M Mitruka
Journal:  Arch Int Pharmacodyn Ther       Date:  1972

8.  The concentrations of free amino acids and other electrolytes in cerebrospinal fluid, in vivo dialysate of brain, and blood plasma of the dog.

Authors:  L Bito; H Davson; E Levin; M Murray; N Snider
Journal:  J Neurochem       Date:  1966-11       Impact factor: 5.372

9.  Steady-state theory for quantitative microdialysis of solutes and water in vivo and in vitro.

Authors:  P M Bungay; P F Morrison; R L Dedrick
Journal:  Life Sci       Date:  1990       Impact factor: 5.037

10.  Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue.

Authors:  D Moatti-Sirat; F Capron; V Poitout; G Reach; D S Bindra; Y Zhang; G S Wilson; D R Thévenot
Journal:  Diabetologia       Date:  1992-03       Impact factor: 10.122

View more
  13 in total

1.  In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring. Interview by Judy Jones.

Authors:  J Pickup; O Rolinski; D Birch
Journal:  BMJ       Date:  1999-11-13

Review 2.  Current problems and potential techniques in in vivo glucose monitoring.

Authors:  Y Wickramasinghe; Y Yang; S A Spencer
Journal:  J Fluoresc       Date:  2004-09       Impact factor: 2.217

Review 3.  Can hypoglycaemia be predicted before its onset?

Authors:  P Lönnroth
Journal:  Diabetologia       Date:  1996-05       Impact factor: 10.122

Review 4.  Does fall in tissue glucose precede fall in blood glucose?

Authors:  F Sternberg; C Meyerhoff; F J Mennel; H Mayer; F Bischof; E F Pfeiffer
Journal:  Diabetologia       Date:  1996-05       Impact factor: 10.122

5.  Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

Authors:  Cosimo Scuffi; Fausto Lucarelli; Francesco Valgimigli
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

6.  Chemical monitoring of intensive care patients using intravenous microdialysis.

Authors:  H Stjernström; T Karlsson; U Ungerstedt; L Hillered
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

7.  Comments on subcutaneous glucose monitoring.

Authors:  F Sternberg; C Meyerhoff; F J Mennel; F Bischof; H Mayer; E F Pfeiffer
Journal:  Diabetologia       Date:  1994-05       Impact factor: 10.122

8.  Reverse iontophoresis: development of a noninvasive approach for glucose monitoring.

Authors:  G Rao; P Glikfeld; R H Guy
Journal:  Pharm Res       Date:  1993-12       Impact factor: 4.200

9.  Continuous subcutaneous glucose monitoring shows a close correlation between mean glucose and time spent in hyperglycemia and hemoglobin A1c.

Authors:  Jannik Kruse Nielsen; Claus Højbjerg Gravholt; Christian Born Djurhuus; Derek Brandt; Joern Becker; Lutz Heinemann; Jens Sandahl Christiansen
Journal:  J Diabetes Sci Technol       Date:  2007-11

10.  Continuous monitoring of lactate during exercise in humans using subcutaneous and transcutaneous microdialysis.

Authors:  J de Boer; H Plijter-Groendijk; K R Visser; G A Mook; J Korf
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.