Literature DB >> 27278517

Clinical utility of automated ablation lesion tagging based on catheter stability information (VisiTag Module of the CARTO 3 System) with contact force-time integral during pulmonary vein isolation for atrial fibrillation.

Yasuo Okumura1, Ichiro Watanabe2, Kazuki Iso2, Koichi Nagashima2, Kazumasa Sonoda2, Naoko Sasaki2, Rikitake Kogawa2, Keiko Takahashi2, Kimie Ohkubo2, Toshiko Nakai2, Shiro Nakahara3, Yuuichi Hori3, Atsushi Hirayama2.   

Abstract

BACKGROUND: The clinical utility of an automated lesion tagging module based on catheter stability information (VisiTag) with the CARTO system during atrial fibrillation (AF) ablation remains to be established. We investigated whether VisiTag-guided extensive encircling pulmonary vein isolation (EEPVI) produces durable lesions.
METHODS: The study involved 54 patients undergoing EEPVI for paroxysmal AF. We performed EEPVI guided by the module-generated ablation tags, i.e., "VisiTags," which are point-by-point ablation tags placed on 3D maps. The patients were divided into two groups: those treated under a moderate catheter stability VisiTag setting, i.e., a 3-mm distance limit for at least 5 s and a minimum contact force (CF) of 8 g over 25 % of the set time period with a target force-time integral (FTI) ≥300 g*s (n = 27), and those treated under a strict catheter stability setting, i.e., a 3-mm distance limit for at least 10 s and a minimum CF of 10 g over 50 % of the set time period with a target FTI ≥400 g*s (n = 27).
RESULTS: After EEPVI, adenosine triphosphate-provoked dormant PV conduction was observed in six (22 %) patients in the moderate catheter stability group and in one (4 %) patient in the strict catheter stability group (p = 0.1003); the 12.9-month success rate was 81 % in both groups.
CONCLUSIONS: The strict catheter stability setting for automated lesion tagging together with a target FTI of >400 g*s, vs. the moderate catheter stability setting with a target FTI of >300 g*s, produces less frequent ATP-provoked PV conduction and yields a comparably high mid-term success rate.

Entities:  

Keywords:  Ablation; Atrial fibrillation; Catheter stability; Contact force; Force-time integral

Mesh:

Year:  2016        PMID: 27278517     DOI: 10.1007/s10840-016-0156-z

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  17 in total

1.  The importance of catheter stability evaluated by Visitag(TM) during pulmonary vein isolation.

Authors:  Ryudo Fujiwara; Kimitake Imamura; Yoichi Kijima; Tomoya Masano; Ryoji Nagoshi; Amane Kohzuki; Hiroyuki Shibata; Yoshiro Tsukiyama; Ryo Takeshige; Kenichi Yanaka; Shinsuke Nakano; Yusuke Fukuyama; Junya Shite
Journal:  J Interv Card Electrophysiol       Date:  2016-01-19       Impact factor: 1.900

2.  Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study.

Authors:  Jason G Andrade; George Monir; Scott J Pollak; Paul Khairy; Marc Dubuc; Denis Roy; Mario Talajic; Marc Deyell; Léna Rivard; Bernard Thibault; Peter G Guerra; Stanley Nattel; Laurent Macle
Journal:  Heart Rhythm       Date:  2014-07-25       Impact factor: 6.343

3.  Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial.

Authors:  Andrea Natale; Vivek Y Reddy; George Monir; David J Wilber; Bruce D Lindsay; H Thomas McElderry; Charan Kantipudi; Moussa C Mansour; Daniel P Melby; Douglas L Packer; Hiroshi Nakagawa; Baohui Zhang; Robert B Stagg; Lee Ming Boo; Francis E Marchlinski
Journal:  J Am Coll Cardiol       Date:  2014-08-19       Impact factor: 24.094

4.  Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions.

Authors:  Fabien Squara; Decebal Gabriel Latcu; Youssef Massaad; Marouane Mahjoub; Sok-Sithikun Bun; Nadir Saoudi
Journal:  Europace       Date:  2014-05       Impact factor: 5.214

5.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

6.  Effect of catheter tip-tissue surface contact on three-dimensional left atrial and pulmonary vein geometries: potential anatomic distortion of 3D ultrasound, fast anatomical mapping, and merged 3D CT-derived images.

Authors:  Yasuo Okumura; Ichiro Watanabe; Masayoshi Kofune; Koichi Nagashima; Kazumasa Sonoda; Hiroaki Mano; Kimie Ohkubo; Toshiko Nakai; Naoko Sasaki; Rikitake Kogawa; Ayako Maruyama; Atsushi Hirayama
Journal:  J Cardiovasc Electrophysiol       Date:  2012-12-21

7.  ATP-induced dormant pulmonary veins originating from the carina region after circumferential pulmonary vein isolation of atrial fibrillation.

Authors:  Koji Kumagai; Shigeto Naito; Koki Nakamura; Tatsuya Hayashi; Rie Fukazawa; Chizuru Sato; Naoki Takemura; Yuko Miki; Etsuko Fuke; Yasuaki Tanaka; Yasuhiko Hori; Koji Goto; Jotaro Iwamoto; Kazutaka Aonuma; Shigeru Oshima; Koichi Taniguchi
Journal:  J Cardiovasc Electrophysiol       Date:  2009-12-15

8.  Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique.

Authors:  Feifan Ouyang; Matthias Antz; Sabine Ernst; Hitoshi Hachiya; Hercules Mavrakis; Florian T Deger; Anselm Schaumann; Julian Chun; Peter Falk; Detlef Hennig; Xingpeng Liu; Dietmar Bänsch; Karl-Heinz Kuck
Journal:  Circulation       Date:  2004-12-27       Impact factor: 29.690

9.  Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance.

Authors:  Chan-Il Park; Heiko Lehrmann; Cornelius Keyl; Reinhold Weber; Jochen Schiebeling; Juergen Allgeier; Patrick Schurr; Ashok Shah; Franz-Josef Neumann; Thomas Arentz; Amir S Jadidi
Journal:  J Cardiovasc Electrophysiol       Date:  2014-04-02

10.  "Dormant" pulmonary vein conduction revealed by adenosine after ostial radiofrequency catheter ablation.

Authors:  Thomas Arentz; Laurent Macle; Dietrich Kalusche; Mélèze Hocini; Pierre Jais; Dipen Shah; Michel Haissaguerre
Journal:  J Cardiovasc Electrophysiol       Date:  2004-09
View more
  9 in total

1.  Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation.

Authors:  Benjamin Schaeffer; Stephan Willems; Christian Meyer; Jakob Lüker; Ruken Ö Akbulak; Julia Moser; Mario Jularic; Christian Eickholt; Jana M Schwarzl; Melanie Gunawardene; Pawel Kuklik; Arian Sultan; Boris A Hoffmann; Daniel Steven
Journal:  Clin Res Cardiol       Date:  2018-03-02       Impact factor: 5.460

2.  High-voltage zones within the pulmonary vein antra: Major determinants of acute pulmonary vein reconnections after atrial fibrillation ablation.

Authors:  Koichi Nagashima; Ichiro Watanabe; Yasuo Okumura; Kazuki Iso; Keiko Takahashi; Ryuta Watanabe; Masaru Arai; Sayaka Kurokawa; Toshiko Nakai; Kimie Ohkubo; Shunichi Yoda; Atsushi Hirayama
Journal:  J Interv Card Electrophysiol       Date:  2017-04-21       Impact factor: 1.900

3.  Gains in Paroxysmal Atrial Fibrillation Ablation Using a Standardized Workflow to Optimize Contact Force Technologies.

Authors:  Jose Osorio; Tina D Hunter; Rosemary S Bubien; Anil Rajendra; Joaquin Arciniegas; Gustavo Morales
Journal:  J Atr Fibrillation       Date:  2018-12-31

4.  Mechanistic Insights Into Durable Pulmonary Vein Isolation Achieved by Second-Generation Cryoballoon Ablation.

Authors:  Yasuo Okumura; Ichiro Watanabe; Kazuki Iso; Keiko Takahashi; Koichi Nagashima; Kazumasa Sonoda; Hiroaki Mano; Naoko Yamaguchi; Rikitake Kogawa; Ryuta Watanabe; Masaru Arai; Kimie Ohkubo; Sayaka Kurokawa; Toshiko Nakai; Atsushi Hirayama
Journal:  J Atr Fibrillation       Date:  2017-04-30

Review 5.  Paroxysmal atrial fibrillation ablation: Achieving permanent pulmonary vein isolation by point-by-point radiofrequency lesions.

Authors:  Alonso Pedrote; Juan Acosta; Beatriz Jáuregui-Garrido; Manuel Frutos-López; Eduardo Arana-Rueda
Journal:  World J Cardiol       Date:  2017-03-26

6.  Influence of balloon temperature and time to pulmonary vein isolation on acute pulmonary vein reconnection and clinical outcomes after cryoballoon ablation of atrial fibrillation.

Authors:  Ryuta Watanabe; Yasuo Okumura; Koichi Nagashima; Kazuki Iso; Keiko Takahashi; Masaru Arai; Yuji Wakamatsu; Sayaka Kurokawa; Kimie Ohkubo; Toshiko Nakai; Shunichi Yoda; Ichiro Watanabe; Atsushi Hirayama; Kazumasa Sonoda; Toshimasa Tosaka
Journal:  J Arrhythm       Date:  2018-09-03

7.  How is Contact Force implemented in routine clinical practice? Results from a French National and Monaco Survey.

Authors:  Sok-Sithikun Bun; Decebal Gabriel Lațcu; Philippe Taghji; Frederic Anselme; Serge Boveda; Jean-Pierre Cebron; Pascal Defaye; Jean-Claude Deharo; Laurent Fauchier; Estelle Gandjbakhch; Daniel Gras; Didier Klug; Jacques Mansourati; Eloi Marijon; Jean-Philippe Maury; Fabien Squara; Nadir Saoudi; Jérôme Taïeb
Journal:  J Arrhythm       Date:  2019-02-15

8.  Optimization of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study.

Authors:  Henry Chubb; Shadman Aziz; Rashed Karim; Christian Sohns; Orod Razeghi; Steven E Williams; John Whitaker; James Harrison; Amedeo Chiribiri; Tobias Schaeffter; Matthew Wright; Mark O'Neill; Reza Razavi
Journal:  J Cardiovasc Magn Reson       Date:  2018-05-03       Impact factor: 5.364

9.  Comparison of the efficacy between impedance-guided and contact force-guided atrial fibrillation ablation using an automated annotation system.

Authors:  Hyoung-Seob Park; In-Cheol Kim; Yun-Kyeong Cho; Hyuck-Jun Yoon; Hyungseop Kim; Chang-Wook Nam; Seongwook Han; Seung-Ho Hur; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  J Arrhythm       Date:  2018-04-11
  9 in total