Literature DB >> 24575734

Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance.

Chan-Il Park1, Heiko Lehrmann, Cornelius Keyl, Reinhold Weber, Jochen Schiebeling, Juergen Allgeier, Patrick Schurr, Ashok Shah, Franz-Josef Neumann, Thomas Arentz, Amir S Jadidi.   

Abstract

INTRODUCTION: Pulmonary vein reconnection (PVR) is an important cause of AF recurrence after ablation. With the advent of force sensing catheters, catheter-tissue contact can be determined quantitatively. Since contact force (CF) plays a major role in determining the characteristics of RF lesion, we prospectively assessed the mechanisms of PVR with regard to catheter-contact and lesion distances in patients undergoing AF ablation. METHODS AND
RESULTS: Forty symptomatic AF patients underwent wide circumferential PV isolation (PVI) with SmartTouch™ CF catheter. The exact locations of acute PVI and spontaneous or adenosine-provoked PVR were annotated on CARTO. One thousand nine hundred and twenty-six RF lesions isolated 153 PVs. PVR occurred in 35 (23%) PVs: 22 (63%) adenosine-provoked and 13 (37%) spontaneous. CF was significantly lower at PVR versus PVI sites for RF lesions within 6 mm from these sites: mean CF 5 versus 11 g (P < 0.0001) and force-time integral (FTI) 225 versus 415 gs (P < 0.0001); 86% of PVR occurred with a mean CF < 10 g (FTI < 400 gs); and the remaining 14% occurred at ablation sites with a long interlesion distance (≥5 mm) despite mean CF ≥ 10 g. Eighty percent of PVR sites were located anteriorly. There were no significant differences in regard to arrhythmia freedom between the patients without (69%) versus with PVR (67%; P = 1.0).
CONCLUSIONS: Acutely durable PVI can be achieved when RF lesions are delivered with a mean CF ≥ 10 g and an interlesion distance <5 mm. The majority of PVR occur anteriorly due to inadequate CF or long interlesion distances.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  adenosine; atrial fibrillation; catheter ablation; contact force; pulmonary vein isolation; pulmonary vein reconnection

Mesh:

Substances:

Year:  2014        PMID: 24575734     DOI: 10.1111/jce.12396

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  36 in total

1.  Lesion index: a novel guide in the path of successful pulmonary vein isolation.

Authors:  Antonio Dello Russo; Gaetano M Fassini; Michela Casella; Elena Romanelli; Salvatore Pala; Stefania Riva; Valentina Catto; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Maria Antonietta Dessanai; Francesca Pizzamiglio; Giulia Vettor; Valentina Ribatti; Alessio Gasperetti; Selene Cellucci; Gabriele Negro; Rita Sicuso; Corrado Carbucicchio; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2018-12-04       Impact factor: 1.900

2.  The importance of catheter stability evaluated by Visitag(TM) during pulmonary vein isolation.

Authors:  Ryudo Fujiwara; Kimitake Imamura; Yoichi Kijima; Tomoya Masano; Ryoji Nagoshi; Amane Kohzuki; Hiroyuki Shibata; Yoshiro Tsukiyama; Ryo Takeshige; Kenichi Yanaka; Shinsuke Nakano; Yusuke Fukuyama; Junya Shite
Journal:  J Interv Card Electrophysiol       Date:  2016-01-19       Impact factor: 1.900

3.  Clinical utility of automated ablation lesion tagging based on catheter stability information (VisiTag Module of the CARTO 3 System) with contact force-time integral during pulmonary vein isolation for atrial fibrillation.

Authors:  Yasuo Okumura; Ichiro Watanabe; Kazuki Iso; Koichi Nagashima; Kazumasa Sonoda; Naoko Sasaki; Rikitake Kogawa; Keiko Takahashi; Kimie Ohkubo; Toshiko Nakai; Shiro Nakahara; Yuuichi Hori; Atsushi Hirayama
Journal:  J Interv Card Electrophysiol       Date:  2016-06-09       Impact factor: 1.900

4.  Left atrial anterior line ablation using ablation index and inter-lesion distance measurement.

Authors:  Francesco Santoro; Andreas Metzner; Natale Daniele Brunetti; Christian-H Heeger; Shibu Mathew; Bruno Reissmann; Christine Lemeš; Tilman Maurer; Thomas Fink; Laura Rottner; Osamu Inaba; Karl-Heinz Kuck; Feifan Ouyang; Andreas Rillig
Journal:  Clin Res Cardiol       Date:  2019-02-02       Impact factor: 5.460

5.  Automated lesion annotation during pulmonary vein isolation: influence on acute isolation rates and lesion characteristics.

Authors:  Stefan Asbach; Corinna Lang; Luca Trolese; Christoph Bode; Fabienne Schluermann
Journal:  J Interv Card Electrophysiol       Date:  2016-08-10       Impact factor: 1.900

6.  [Pulmonary vein isolation using radiofrequency ablation].

Authors:  Leon Iden; Sonia Busch; Daniel Steven; Roland R Tilz; Dong-In Shin; K R Julian Chun; Heidi Estner; Felix Bourier; David Duncker; Philipp Sommer; Andreas Metzner; Tilman Maurer; Nils-Christian Ewertsen; Henning Jansen; Andreas Rillig; Victoria Johnson; Till Althoff
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2021-07-26

7.  Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation.

Authors:  Benjamin Schaeffer; Stephan Willems; Christian Meyer; Jakob Lüker; Ruken Ö Akbulak; Julia Moser; Mario Jularic; Christian Eickholt; Jana M Schwarzl; Melanie Gunawardene; Pawel Kuklik; Arian Sultan; Boris A Hoffmann; Daniel Steven
Journal:  Clin Res Cardiol       Date:  2018-03-02       Impact factor: 5.460

8.  Evolution of Force Sensing Technologies.

Authors:  Dipen Shah
Journal:  Arrhythm Electrophysiol Rev       Date:  2017-06

9.  Increasing the Single-Procedure Success Rate of Pulmonary Vein Isolation.

Authors:  Mattias Duytschaever; Mark O'Neill; Martin Martinek
Journal:  Arrhythm Electrophysiol Rev       Date:  2017-12

10.  Randomized comparison of contact force-guided versus conventional circumferential pulmonary vein isolation of atrial fibrillation: prevalence, characteristics, and predictors of electrical reconnections and clinical outcomes.

Authors:  Kohki Nakamura; Shigeto Naito; Takehito Sasaki; Masahiro Nakano; Kentaro Minami; Yosuke Nakatani; Kentaro Ikeda; Eiji Yamashita; Koji Kumagai; Nobusada Funabashi; Shigeru Oshima
Journal:  J Interv Card Electrophysiol       Date:  2015-09-19       Impact factor: 1.900

View more