Literature DB >> 28432503

High-voltage zones within the pulmonary vein antra: Major determinants of acute pulmonary vein reconnections after atrial fibrillation ablation.

Koichi Nagashima1, Ichiro Watanabe2, Yasuo Okumura2, Kazuki Iso2, Keiko Takahashi2, Ryuta Watanabe2, Masaru Arai2, Sayaka Kurokawa2, Toshiko Nakai2, Kimie Ohkubo2, Shunichi Yoda2, Atsushi Hirayama2.   

Abstract

PURPOSE: Recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) is mainly due to PV reconnections. Patient-specific tissue characteristics that may contribute remain unidentified. This study aimed to assess the relationship between the bipolar electrogram voltage amplitudes recorded from the PV-left atrial (LA) junction and acute PV reconnection sites.
METHODS: Three-dimensional LA voltage maps created before an extensive encircling PVI in 47 AF patients (31 men; mean age 62 ± 11 years) were examined for an association between the EGM voltage amplitude recorded from the PV-LA junction and acute post-PVI PV reconnections (spontaneous PV reconnections and/or ATP-provoked dormant PV conduction).
RESULTS: Acute PV reconnections were observed in 17 patients (36%) and in 24 (3%) of the 748 PV segments (16 segments per patient) and were associated with relatively high bipolar voltage amplitudes (3.26 ± 0.85 vs. 1.79 ± 1.15 mV, p < 0.0001) and a relatively low mean force-time integral (FTI) (428 ± 56 vs. 473 ± 76 gs, p = 0.0039) as well as FTI/PV-LA bipolar voltage (137 [106, 166] vs. 295 [193, 498] gs/mV, p < 0.0001). An analysis of the receiver operating characteristic curves revealed a high prognostic performance of the LA bipolar voltage and FTI/PV-LA bipolar voltage for acute PV reconnections (areas under the curve: 0.86 and 0.89, respectively); the best cutoff values were >2.12 mV and ≤183 gs/mV, respectively.
CONCLUSIONS: The PV-LA voltage on the PV-encircling ablation line and FTI/PV-LA voltage were related to the acute post-PVI PV reconnections. A more durable ablation strategy is warranted for high-voltage zones.

Entities:  

Keywords:  Atrial fibrillation; High voltage zone; Pulmonary vein isolation

Mesh:

Year:  2017        PMID: 28432503     DOI: 10.1007/s10840-017-0252-8

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  18 in total

1.  Pulmonary Vein Antrum Isolation in Patients With Paroxysmal Atrial Fibrillation: More Than a Decade of Follow-Up.

Authors:  Yalçin Gökoğlan; Sanghamitra Mohanty; Mahmut F Güneş; Chintan Trivedi; Pasquale Santangeli; Carola Gianni; Issa K Asfour; Rong Bai; J David Burkhardt; Rodney Horton; Javier Sanchez; Steven Hao; Richard Hongo; Salwa Beheiry; Luigi Di Biase; Andrea Natale
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-05

2.  Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.

Authors:  Petr Neuzil; Vivek Y Reddy; Josef Kautzner; Jan Petru; Dan Wichterle; Dipen Shah; Hendrik Lambert; Aude Yulzari; Erik Wissner; Karl-Heinz Kuck
Journal:  Circ Arrhythm Electrophysiol       Date:  2013-03-20

3.  Association between epicardial adipose tissue volumes on 3-dimensional reconstructed CT images and recurrence of atrial fibrillation after catheter ablation.

Authors:  Koichi Nagashima; Yasuo Okumura; Ichiro Watanabe; Toshiko Nakai; Kimie Ohkubo; Tatsuya Kofune; Masayoshi Kofune; Hiroaki Mano; Kazumasa Sonoda; Atsushi Hirayama
Journal:  Circ J       Date:  2011-08-26       Impact factor: 2.993

4.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

5.  Electrophysiological breakthroughs from the left atrium to the pulmonary veins.

Authors:  M Haïssaguerre; D C Shah; P Jaïs; M Hocini; T Yamane; I Deisenhofer; M Chauvin; S Garrigue; J Clémenty
Journal:  Circulation       Date:  2000-11-14       Impact factor: 29.690

6.  Clinical implications of reconnection between the left atrium and isolated pulmonary veins provoked by adenosine triphosphate after extensive encircling pulmonary vein isolation.

Authors:  Hitoshi Hachiya; Kenzo Hirao; Atsushi Takahashi; Yasutoshi Nagata; Kenji Suzuki; Shingo Maeda; Takeshi Sasaki; Mihoko Kawabata; Mitsuaki Isobe; Yoshito Iesaka
Journal:  J Cardiovasc Electrophysiol       Date:  2007-02-07

7.  Adenosine-guided pulmonary vein isolation for the treatment of paroxysmal atrial fibrillation: an international, multicentre, randomised superiority trial.

Authors:  Laurent Macle; Paul Khairy; Rukshen Weerasooriya; Paul Novak; Atul Verma; Stephan Willems; Thomas Arentz; Isabel Deisenhofer; George Veenhuyzen; Christophe Scavée; Pierre Jaïs; Helmut Puererfellner; Sylvie Levesque; Jason G Andrade; Lena Rivard; Peter G Guerra; Marc Dubuc; Bernard Thibault; Mario Talajic; Denis Roy; Stanley Nattel
Journal:  Lancet       Date:  2015-07-23       Impact factor: 79.321

8.  "Dormant" pulmonary vein conduction revealed by adenosine after ostial radiofrequency catheter ablation.

Authors:  Thomas Arentz; Laurent Macle; Dietrich Kalusche; Mélèze Hocini; Pierre Jais; Dipen Shah; Michel Haissaguerre
Journal:  J Cardiovasc Electrophysiol       Date:  2004-09

9.  EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation.

Authors:  Josef Kautzner; Petr Neuzil; Hendrik Lambert; Petr Peichl; Jan Petru; Robert Cihak; Jan Skoda; Dan Wichterle; Erik Wissner; Aude Yulzari; Karl-Heinz Kuck
Journal:  Europace       Date:  2015-06-03       Impact factor: 5.214

10.  Pulmonary vein reconnection predicts good clinical outcome after second catheter ablation for atrial fibrillation.

Authors:  Tae-Hoon Kim; Junbeom Park; Jae-Sun Uhm; Boyoung Joung; Moon-Hyoung Lee; Hui-Nam Pak
Journal:  Europace       Date:  2017-06-01       Impact factor: 5.214

View more
  3 in total

1.  Influence of balloon temperature and time to pulmonary vein isolation on acute pulmonary vein reconnection and clinical outcomes after cryoballoon ablation of atrial fibrillation.

Authors:  Ryuta Watanabe; Yasuo Okumura; Koichi Nagashima; Kazuki Iso; Keiko Takahashi; Masaru Arai; Yuji Wakamatsu; Sayaka Kurokawa; Kimie Ohkubo; Toshiko Nakai; Shunichi Yoda; Ichiro Watanabe; Atsushi Hirayama; Kazumasa Sonoda; Toshimasa Tosaka
Journal:  J Arrhythm       Date:  2018-09-03

2.  Effectiveness of the Early Staged Hybrid Approach for Treatment of Symptomatic Atrial Fibrillation: the Electrophysiology Study Could Be Deferred?

Authors:  Ju Youn Kim; Dong Seop Jeong; Hee-Jin Kwon; Seung-Jung Park; Kyoung-Min Park; June Soo Kim; Young Keun On
Journal:  J Korean Med Sci       Date:  2021-11-08       Impact factor: 2.153

3.  Optimized lesion size index (o-LSI): A novel predictor for sufficient ablation of pulmonary vein isolation.

Authors:  Gen Matsuura; Jun Kishihara; Hidehira Fukaya; Jun Oikawa; Naruya Ishizue; Daiki Saito; Tetsuro Sato; Yuki Arakawa; Shuhei Kobayashi; Yuki Shirakawa; Ryo Nishinarita; Ai Horiguchi; Shinichi Niwano; Junya Ako
Journal:  J Arrhythm       Date:  2021-04-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.