Literature DB >> 27242344

Evaluation of Effective Dose from CT Scans for Overweight and Obese Adult Patients Using the VirtualDose Software.

Baohui Liang1,2, Yiming Gao3, Zhi Chen1, X George Xu1,3.   

Abstract

This paper evaluates effective dose (ED) of overweight and obese patients who undergo body computed tomography (CT) examinations. ED calculations were based on tissue weight factors in the International Commission on Radiological Protection Publication 103 (ICRP 103). ED per unit dose length product (DLP) are reported as a function of the tube voltage, body mass index (BMI) of patient. The VirtualDose software was used to calculate ED for male and female obese phantoms representing normal weight, overweight, obese 1, obese 2 and obese 3 patients. Five anatomic regions (chest, abdomen, pelvis, abdomen/pelvis and chest/abdomen/pelvis) were investigated for each phantom. The conversion factors were computed from the DLP, and then compared with data previously reported by other groups. It was observed that tube voltage and BMI are the major factors that influence conversion factors of obese patients, and that ED computed using ICRP 103 tissue weight factors were 24% higher for a CT chest examination and 21% lower for a CT pelvis examination than the ED using ICRP 60 factors. For body CT scans, increasing the tube voltage from 80 to 140 kVp would increase the conversion factors by as much as 19-54% depending on the patient's BMI. Conversion factor of female patients was ~7% higher than the factors of male patients. DLP and conversion factors were used to estimate ED, where conversion factors depended on tube voltage, sex, BMI and tissue weight factors. With increasing number of obese individuals, using size-dependence conversion factors will improve accuracy, in estimating patient radiation dose.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2017        PMID: 27242344      PMCID: PMC7462054          DOI: 10.1093/rpd/ncw119

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  30 in total

1.  How to estimate multislice CT effective dose more correctly.

Authors:  Mikhail Zelikman; Sergey Kruchinin; Viacheslav Burashov
Journal:  Health Phys       Date:  2013-12       Impact factor: 1.316

2.  Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations.

Authors:  Choonsik Lee; Kwang Pyo Kim; Daniel Long; Ryan Fisher; Chris Tien; Steven L Simon; Andre Bouville; Wesley E Bolch
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

3.  CT effective dose per dose length product using ICRP 103 weighting factors.

Authors:  Walter Huda; Dennise Magill; Wenjun He
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

Review 4.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

5.  Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

Authors:  Paul D Deak; Yulia Smal; Willi A Kalender
Journal:  Radiology       Date:  2010-10       Impact factor: 11.105

6.  Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation.

Authors:  Choonsik Lee; Kwang Pyo Kim; Daniel J Long; Wesley E Bolch
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

7.  Effects of protocol and obesity on dose conversion factors in adult body CT.

Authors:  Xiang Li; Ehsan Samei; Cameron H Williams; W Paul Segars; Daniel J Tward; Michael I Miller; J Tilak Ratnanather; Erik K Paulson; Donald P Frush
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

8.  Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination.

Authors:  Choonik Lee; Choonsik Lee; Robert J Staton; David E Hintenlang; Manuel M Arreola; Jonathon L Williams; Wesley E Bolch
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

9.  Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models.

Authors:  Xiaoyu Tian; Xiang Li; W Paul Segars; Donald P Frush; Erik K Paulson; Ehsan Samei
Journal:  Phys Med Biol       Date:  2013-12-04       Impact factor: 3.609

10.  Global, regional, and national prevalence of overweight and obesity in children and adults during 1980-2013: a systematic analysis for the Global Burden of Disease Study 2013.

Authors:  Marie Ng; Tom Fleming; Margaret Robinson; Blake Thomson; Nicholas Graetz; Christopher Margono; Erin C Mullany; Stan Biryukov; Cristiana Abbafati; Semaw Ferede Abera; Jerry P Abraham; Niveen M E Abu-Rmeileh; Tom Achoki; Fadia S AlBuhairan; Zewdie A Alemu; Rafael Alfonso; Mohammed K Ali; Raghib Ali; Nelson Alvis Guzman; Walid Ammar; Palwasha Anwari; Amitava Banerjee; Simon Barquera; Sanjay Basu; Derrick A Bennett; Zulfiqar Bhutta; Jed Blore; Norberto Cabral; Ismael Campos Nonato; Jung-Chen Chang; Rajiv Chowdhury; Karen J Courville; Michael H Criqui; David K Cundiff; Kaustubh C Dabhadkar; Lalit Dandona; Adrian Davis; Anand Dayama; Samath D Dharmaratne; Eric L Ding; Adnan M Durrani; Alireza Esteghamati; Farshad Farzadfar; Derek F J Fay; Valery L Feigin; Abraham Flaxman; Mohammad H Forouzanfar; Atsushi Goto; Mark A Green; Rajeev Gupta; Nima Hafezi-Nejad; Graeme J Hankey; Heather C Harewood; Rasmus Havmoeller; Simon Hay; Lucia Hernandez; Abdullatif Husseini; Bulat T Idrisov; Nayu Ikeda; Farhad Islami; Eiman Jahangir; Simerjot K Jassal; Sun Ha Jee; Mona Jeffreys; Jost B Jonas; Edmond K Kabagambe; Shams Eldin Ali Hassan Khalifa; Andre Pascal Kengne; Yousef Saleh Khader; Young-Ho Khang; Daniel Kim; Ruth W Kimokoti; Jonas M Kinge; Yoshihiro Kokubo; Soewarta Kosen; Gene Kwan; Taavi Lai; Mall Leinsalu; Yichong Li; Xiaofeng Liang; Shiwei Liu; Giancarlo Logroscino; Paulo A Lotufo; Yuan Lu; Jixiang Ma; Nana Kwaku Mainoo; George A Mensah; Tony R Merriman; Ali H Mokdad; Joanna Moschandreas; Mohsen Naghavi; Aliya Naheed; Devina Nand; K M Venkat Narayan; Erica Leigh Nelson; Marian L Neuhouser; Muhammad Imran Nisar; Takayoshi Ohkubo; Samuel O Oti; Andrea Pedroza; Dorairaj Prabhakaran; Nobhojit Roy; Uchechukwu Sampson; Hyeyoung Seo; Sadaf G Sepanlou; Kenji Shibuya; Rahman Shiri; Ivy Shiue; Gitanjali M Singh; Jasvinder A Singh; Vegard Skirbekk; Nicolas J C Stapelberg; Lela Sturua; Bryan L Sykes; Martin Tobias; Bach X Tran; Leonardo Trasande; Hideaki Toyoshima; Steven van de Vijver; Tommi J Vasankari; J Lennert Veerman; Gustavo Velasquez-Melendez; Vasiliy Victorovich Vlassov; Stein Emil Vollset; Theo Vos; Claire Wang; XiaoRong Wang; Elisabete Weiderpass; Andrea Werdecker; Jonathan L Wright; Y Claire Yang; Hiroshi Yatsuya; Jihyun Yoon; Seok-Jun Yoon; Yong Zhao; Maigeng Zhou; Shankuan Zhu; Alan D Lopez; Christopher J L Murray; Emmanuela Gakidou
Journal:  Lancet       Date:  2014-05-29       Impact factor: 79.321

View more
  1 in total

1.  Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT.

Authors:  Yiming Gao; Usman Mahmood; Tianyu Liu; Brian Quinn; Marc J Gollub; X George Xu; Lawrence T Dauer
Journal:  AJR Am J Roentgenol       Date:  2019-08-15       Impact factor: 3.959

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.