Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination.

Choonik Lee1, Choonsik Lee, Robert J Staton, David E Hintenlang, Manuel M Arreola, Jonathon L Williams, Wesley E Bolch.   

Abstract

As multidetector computed tomography (CT) serves as an increasingly frequent diagnostic modality, radiation risks to patients became a greater concern, especially for children due to their inherently higher radiosensitivity to stochastic radiation damage. Current dose evaluation protocols include the computed tomography dose index (CTDI) or point detector measurements using anthropomorphic phantoms that do not sufficiently provide accurate information of the organ-averaged absorbed dose and corresponding effective dose to pediatric patients. In this study, organ and effective doses to pediatric patients under helical multislice computed tomography (MSCT) examinations were evaluated using an extensive series of anthropomorphic computational phantoms and Monte Carlo radiation transport simulations. Ten pediatric phantoms, five stylized (equation-based) ORNL phantoms (newborn, 1-year, 5-year, 10-year, and 15-year) and five tomographic (voxel-based) UF phantoms (9-month male, 4-year female, 8-year female, 11-year male, and 14-year male) were implemented into MCNPX for simulation, where a source subroutine was written to explicitly simulate the helical motion of the CT x-ray source and the fan beam angle and collimator width. Ionization chamber measurements were performed and used to normalize the Monte Carlo simulation results. On average, for the same tube current setting, a tube potential of 100 kVp resulted in effective doses that were 105% higher than seen at 80 kVp, and 210% higher at 120 kVp regardless of phantom type. Overall, the ORNL phantom series was shown to yield values of effective dose that were reasonably consistent with those of the gender-specific UF phantom series for CT examinations of the head, pelvis, and torso. However, the ORNL phantoms consistently overestimated values of the effective dose as seen in the UF phantom for MSCT scans of the chest, and underestimated values of the effective dose for abdominal CT scans. These discrepancies increased with increasing kVp. Finally, absorbed doses to select radiation sensitive organs such as the gonads, red bone marrow, colon, and thyroid were evaluated and compared between phantom types. Specific anatomical problems identified in the stylized phantoms included excessive pelvic shielding of the ovaries in the female phantoms, enhanced red bone marrow dose to the arms and rib cage for chest exams, an unrealistic and constant torso thickness resulting in excessive x-ray attenuation in the regions of the abdominal organs, and incorrect positioning of the thyroid within the stylized phantom neck resulting in insufficient shielding by clavicles and scapulae for lateral beam angles. To ensure more accurate estimates of organ absorbed dose in multislice CT, it is recommended that voxel-based phantoms, potentially tailored to individual body morphometry, be utilized in any future prospective epidemiological studies of medically exposed children.

Entities:  

Mesh:

Year:  2007        PMID: 17555267     DOI: 10.1118/1.2723885

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  35 in total

1.  Estimating peak skin and eye lens dose from neuroperfusion examinations: use of Monte Carlo based simulations and comparisons to CTDIvol, AAPM Report No. 111, and ImPACT dosimetry tool values.

Authors:  Di Zhang; Chris H Cagnon; J Pablo Villablanca; Cynthia H McCollough; Dianna D Cody; Maria Zankl; John J Demarco; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

Review 2.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

3.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

Authors:  Adam C Turner; Di Zhang; Hyun J Kim; John J DeMarco; Chris H Cagnon; Erin Angel; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations.

Authors:  Choonsik Lee; Kwang Pyo Kim; Daniel Long; Ryan Fisher; Chris Tien; Steven L Simon; Andre Bouville; Wesley E Bolch
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

5.  Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories.

Authors:  Pooyan Sahbaee; W Paul Segars; Ehsan Samei
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

6.  Evaluation of dose conversion coefficients for an eight-year-old Iranian male phantom undergoing computed tomography.

Authors:  Parisa Akhlaghi; Hashem Miri Hakimabad; Laleh Rafat Motavalli
Journal:  Radiat Environ Biophys       Date:  2015-06-17       Impact factor: 1.925

7.  Accuracy of patient-specific organ dose estimates obtained using an automated image segmentation algorithm.

Authors:  Taly Gilat Schmidt; Adam S Wang; Thomas Coradi; Benjamin Haas; Josh Star-Lack
Journal:  J Med Imaging (Bellingham)       Date:  2016-11-29

8.  Patient-specific dose estimation for pediatric chest CT.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Donald P Frush
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Breast cancer risk 55+ years after irradiation for an enlarged thymus and its implications for early childhood medical irradiation today.

Authors:  M Jacob Adams; Ann Dozier; Roy E Shore; Steven E Lipshultz; Ronald G Schwartz; Louis S Constine; Thomas A Pearson; Marilyn Stovall; Paul Winters; Susan G Fisher
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2010-01       Impact factor: 4.254

10.  Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions.

Authors:  Lucia J M Kroft; Joost J H Roelofs; Jacob Geleijns
Journal:  Pediatr Radiol       Date:  2009-12-08