Literature DB >> 27150344

No Benefit After THA Performed With Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.

Sebastien Parratte1,2, Matthieu Ollivier1,2, Alexandre Lunebourg1,2, Xavier Flecher1,2, Jean-Noel A Argenson3,4.   

Abstract

BACKGROUND: Computer-assisted surgery (CAS) for cup placement has been developed to improve the functional results and to reduce the dislocation rate and wear after total hip arthroplasty (THA). Previously published studies demonstrated radiographic benefits of CAS in terms of implant position, but whether these improvements result in clinically important differences that patients might perceive remains largely unknown. QUESTIONS/PURPOSES: We hypothesized that THA performed with CAS would improve 10-year patient-reported outcomes measured by validated scoring tools, reduce acetabular polyethylene wear as measured using a validated radiological method, and increase survivorship.
METHODS: Sixty patients operated on for a THA between April 2004 and April 2005 were randomized into two groups using either the CAS technique or a conventional technique for cup placement. All patient candidates for a THA with the diagnosis of primary arthritis or avascular necrosis were eligible for the CAS procedure and randomly assigned to the CAS group by the Hospital Informatics Department with use of a systematic sampling method. The patients assigned to the freehand cup placement group were matched for sex, age within 5 years, pathological condition, operatively treated side, and body mass index within 3 points. All patients were operated on through an anterolateral approach (patient in the supine position) using cementless implants. In the CAS group, a specific surgical procedure using an imageless cup positioning computer-based navigation system was performed. There were 16 men and 14 women in each group; mean age was 62 years (range, 24-80 years), and mean body mass index was 25 ± 3 kg/m(2). No patient was lost to followup at 10 years, but five patients have died (two in the CAS group and three in the control group). At the 10-year followup, an independent observer blinded to the type of technique performed patients' evaluation. Cup positioning was evaluated postoperatively using a CT scan in the two groups with results previously published. At 10 years, we assessed subjective functional outcome and quality of life using validated questionnaires (SF-12, Harris hip score [HHS], Hip injury and Osteoarthritis Outcome Score). Wear rate was then evaluated on standardized radiographs using a previously validated semiautomated computer analogic measurement method (dual circle method). Complications and survivorship were compared between groups. With our available sample size, this study had 80% power to detect a difference of 4 points out of 100 on the HHS at the p < 0.05 level.
RESULTS: With the numbers available, we found we found no differences between groups regarding HSS at last followup 95.3 ± 5.9 points (CAS group) versus 96.2 ± 4.5 points, a mean difference of 0.9 points (95% confidence interval [CI], -4.3 to 4.6; p = 0.6). There was no difference between the groups in terms of the mean (± SD) acetabular linear wear at 10 years. The mean wear was 0.71 ± 0.6 mm in the CAS group versus 0.77 ± 0.52 mm in the control group, a mean difference of 0.06 mm (95% CI, -0.1 to 0.2; p = 0.54). With the numbers available, there was no difference between the CAS group and the conventional THA groups in terms of survivorship free from aseptic loosening (100%; 95% CI, 100%-95%, versus 100%; 95% CI, 100%-94%; p = 0.3).
CONCLUSIONS: Our observations suggest that CAS used for cup placement does not confer any substantial advantage in function, wear rate, or survivorship at 10 years after THA. Because CAS is associated with added costs and surgical time, future studies need to identify what clinically relevant advantages it offers, if any, to justify its continued use in THA. LEVEL OF EVIDENCE: Level II, therapeutic study.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27150344      PMCID: PMC5014807          DOI: 10.1007/s11999-016-4863-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

2.  [Measurement of head penetration on digitalized radiographs: reproducibility and accuracy].

Authors:  J Girard; D Touraine; M Soenen; P Massin; P Laffargue; H Migaud
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-04

3.  Does impact sport activity influence total hip arthroplasty durability?

Authors:  Matthieu Ollivier; Solenne Frey; Sebastien Parratte; Xavier Flecher; Jean-Noël Argenson
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

5.  No difference in clinical outcome, bone density and polyethylene wear 5-7 years after standard navigated vs. conventional cementfree total hip arthroplasty.

Authors:  Armin Keshmiri; Christoph Schröter; Markus Weber; Benjamin Craiovan; Joachim Grifka; Tobias Renkawitz
Journal:  Arch Orthop Trauma Surg       Date:  2015-03-24       Impact factor: 3.067

6.  Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study.

Authors:  Sebastien Parratte; Jean-Noel A Argenson
Journal:  J Bone Joint Surg Am       Date:  2007-03       Impact factor: 5.284

7.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

8.  Comparison of limb-length discrepancy after THA: with and without computer navigation.

Authors:  David J Licini; David J Burnikel; R Michael Meneghini; John L Ochsner
Journal:  Orthopedics       Date:  2013-05       Impact factor: 1.390

9.  Cross-cultural adaptation and validation of the French version of the Hip disability and Osteoarthritis Outcome Score (HOOS) in hip osteoarthritis patients.

Authors:  P Ornetti; S Parratte; L Gossec; C Tavernier; J-N Argenson; E M Roos; F Guillemin; J F Maillefert
Journal:  Osteoarthritis Cartilage       Date:  2009-12-29       Impact factor: 6.576

10.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

View more
  16 in total

1.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

2.  From Bench to Bedside: Robotics and Navigation in Orthopaedics-Rise of the Machines or Just Rising Costs?

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2019-04       Impact factor: 4.176

3.  Reply to the Letter to the Editor: Editor's Spotlight/Take 5: No Benefit after THA Performed with Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.

Authors:  Sebastien Parratte; Matthieu Ollivier; Alexandre Lunebourg; Xavier Flecher; Jean-Noel A Argenson
Journal:  Clin Orthop Relat Res       Date:  2016-11-18       Impact factor: 4.176

4.  Computerized navigation for total hip arthroplasty is associated with lower complications and ninety-day readmissions: a nationwide linked analysis.

Authors:  Elizabeth B Gausden; Joseph E Popper; Peter K Sculco; Barret Rush
Journal:  Int Orthop       Date:  2020-01-09       Impact factor: 3.075

5.  Risk factors for dislocation after primary total hip replacement: meta-analysis of 125 studies involving approximately five million hip replacements.

Authors:  Setor K Kunutsor; Matthew C Barrett; Andrew D Beswick; Andrew Judge; Ashley W Blom; Vikki Wylde; Michael R Whitehouse
Journal:  Lancet Rheumatol       Date:  2019-10

Review 6.  Preoperative Guidance With Weight-Bearing Computed Tomography and Patient-Specific Instrumentation in Foot and Ankle Surgery.

Authors:  Jacob Zeitlin; Jensen Henry; Scott Ellis
Journal:  HSS J       Date:  2021-07-07

7.  CORR Insights®: The Impingement-free, Prosthesis-specific, and Anatomy-adjusted Combined Target Zone for Component Positioning in THA Depends on Design and Implantation Parameters of both Components.

Authors:  Nicholas J Giori
Journal:  Clin Orthop Relat Res       Date:  2020-08       Impact factor: 4.755

8.  CORR Insights®: Does An Augmented Reality-based Portable Navigation System Improve the Accuracy of Acetabular Component Orientation During THA? A Randomized Controlled Trial.

Authors:  Brent A Ponce
Journal:  Clin Orthop Relat Res       Date:  2020-05       Impact factor: 4.755

9.  Learning navigation - Learning with navigation. A review.

Authors:  Jean-Yves Jenny; Frederic Picard
Journal:  SICOT J       Date:  2017-06-02

10.  Comparison of Cup Setting Angle Accuracy between Computed Tomography-Based and Computed Tomography-Free Navigation in the Same Patients with Crowe's Classification I or II Hip Dysplasia.

Authors:  Nobuhiro Kaku; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  Clin Orthop Surg       Date:  2021-04-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.