Literature DB >> 25801810

No difference in clinical outcome, bone density and polyethylene wear 5-7 years after standard navigated vs. conventional cementfree total hip arthroplasty.

Armin Keshmiri1, Christoph Schröter, Markus Weber, Benjamin Craiovan, Joachim Grifka, Tobias Renkawitz.   

Abstract

INTRODUCTION: The purpose of this investigation was to compare clinical outcome, component loosening, polyethylene cup wear and periprosthetic bone mineral density between "cup first" navigated and conventional cementless total hip arthroplasty (THA) 5-7 years after surgery.
MATERIALS AND METHODS: Fifty patients who received THA with (n = 25) or without (n = 25) the use of an image-free navigation system by a single surgeon were investigated after a mean follow-up of 6.4 (4.8-7.4) years. The Hip Osteoarthritis Outcome Score (HOOS) and the Harris Hip Score (HHS) were obtained; range-of-motion (ROM) was evaluated by a blinded examiner. Radiographic cup inclination, signs of radiographic loosening and polyethylene wear were analysed with the help of digital analysis software on anterio-posterior radiographs by a blinded examiner. Acetabular and femoral periprosthetic bone density was evaluated with the help of dual-energy X-ray absorptiometry.
RESULTS: We were unable to find any statistical significant or clinically relevant difference for the HOOS, HHS, ROM and polyethylene wear between the navigated and the conventional THA group 5-7 years after surgery. Cup inclination was more precise in the navigated THA group in relation to the target value of 45°.
CONCLUSIONS: Standard "cup first" THA navigation does not improve mid-term functional outcome, bony ingrowth and/or polyethylene wear. New concepts in computer-assisted THA, considering cup and stem as coupled biomechanical partners are needed to justify the effort of navigation in routine operations.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25801810     DOI: 10.1007/s00402-015-2201-2

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  8 in total

1.  Editor's Spotlight/Take 5: No Benefit After THA Performed With Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.

Authors:  Seth S Leopold
Journal:  Clin Orthop Relat Res       Date:  2016-06-09       Impact factor: 4.176

2.  No Benefit After THA Performed With Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.

Authors:  Sebastien Parratte; Matthieu Ollivier; Alexandre Lunebourg; Xavier Flecher; Jean-Noel A Argenson
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

Review 3.  Technology in Arthroplasty: Are We Improving Value?

Authors:  Bradford S Waddell; Kaitlin Carroll; Seth Jerabek
Journal:  Curr Rev Musculoskelet Med       Date:  2017-09

4.  Retentive Cup Arthroplasty in Selected Hip Fracture Patients-A Prospective Series With a Minimum 3-Year Follow-Up.

Authors:  Mustafa Yassin; Avraham Garti; Muhammad Khatib; Moshe Weisbrot; Dror Robinson
Journal:  Geriatr Orthop Surg Rehabil       Date:  2016-08-08

5.  Advances in hip arthroplasty surgery: what is justified?

Authors:  Luigi Zagra
Journal:  EFORT Open Rev       Date:  2017-05-11

6.  What do we get from navigation in primary THA?

Authors:  Lisa Renner; Viktor Janz; Carsten Perka; Georgi I Wassilew
Journal:  EFORT Open Rev       Date:  2017-03-13

Review 7.  Spinopelvic alignment and low back pain after total hip arthroplasty: a scoping review.

Authors:  Mohammadreza Pourahmadi; Mohammad Sahebalam; Jan Dommerholt; Somayeh Delavari; Mohammad Ali Mohseni-Bandpei; Abbasali Keshtkar; César Fernández-de-Las-Peñas; Mohammad Ali Mansournia
Journal:  BMC Musculoskelet Disord       Date:  2022-03-15       Impact factor: 2.362

8.  Trends and patient factors associated with technology-assisted total hip arthroplasty in the United States from 2005 to 2014.

Authors:  Peter P Hsiue; Clark J Chen; Cristina Villalpando; Danielle Ponzio; Amir Khoshbin; Alexandra I Stavrakis
Journal:  Arthroplast Today       Date:  2020-03-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.