Convolution-based estimation of organ dose in tube current modulated CT.

Xiaoyu Tian1, W Paul Segars, Robert L Dixon, Ehsan Samei.   

Abstract

Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients ([Formula: see text]) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate [Formula: see text] values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying [Formula: see text] with the organ dose coefficients ([Formula: see text]). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The discrepancy between the estimated organ dose and dose simulated using TCM Monte Carlo program was quantified. We further compared the convolution-based organ dose estimation method with two other strategies with different approaches of quantifying the irradiation field. The proposed convolution-based estimation method showed good accuracy with the organ dose simulated using the TCM Monte Carlo simulation. The average percentage error (normalized by CTDIvol) was generally within 10% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. This study developed an improved method that accurately quantifies the irradiation field under TCM scans. The results suggested that organ dose could be estimated in real-time both prospectively (with the localizer information only) and retrospectively (with acquired CT data).

Entities:  

Mesh:

Year:  2016        PMID: 27119974      PMCID: PMC5070791          DOI: 10.1088/0031-9155/61/10/3935

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

3.  Dose equations for tube current modulation in CT scanning and the interpretation of the associated CTDIvol.

Authors:  Robert L Dixon; John M Boone
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

4.  Radiation dose optimization and thoracic computed tomography.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Ranish Deedar Ali Khawaja; Atul Padole; Sarvenaz Pourjabbar; Diego Lira; Jo-Anne O Shepard; Subba R Digumarthy
Journal:  Radiol Clin North Am       Date:  2013-09-20       Impact factor: 2.303

5.  Radiation dose calculations for CT scans with tube current modulation using the approach to equilibrium function.

Authors:  Xinhua Li; Da Zhang; Bob Liu
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

6.  The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults--application to CT dosimetry.

Authors:  Amy M Geyer; Shannon O'Reilly; Choonsik Lee; Daniel J Long; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

7.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  Patient-specific radiation dose and cancer risk for pediatric chest CT.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Donald P Frush
Journal:  Radiology       Date:  2011-04-05       Impact factor: 11.105

9.  Determining organ dose: the holy grail.

Authors:  Ehsan Samei; Xiaoyu Tian; W Paul Segars
Journal:  Pediatr Radiol       Date:  2014-10-11

10.  Anthropometric approaches and their uncertainties to assigning computational phantoms to individual patients in pediatric dosimetry studies.

Authors:  Scott Whalen; Choonsik Lee; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2007-12-28       Impact factor: 3.609

View more
  8 in total

Review 1.  Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.

Authors:  W Paul Segars; B M W Tsui; George S K Fung; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2017-08-10       Impact factor: 10.048

2.  A real-time Monte Carlo tool for individualized dose estimations in clinical CT.

Authors:  Shobhit Sharma; Anuj Kapadia; Wanyi Fu; Ehsan Abadi; W Paul Segars; Ehsan Samei
Journal:  Phys Med Biol       Date:  2019-11-04       Impact factor: 3.609

3.  Organ doses from CT localizer radiographs: Development, validation, and application of a Monte Carlo estimation technique.

Authors:  Jocelyn Hoye; Shobhit Sharma; Yakun Zhang; Wanyi Fu; Francesco Ria; Anuj Kapadia; W Paul Segars; Joshua Wilson; Ehsan Samei
Journal:  Med Phys       Date:  2019-09-16       Impact factor: 4.071

4.  Estimating lung, breast, and effective dose from low-dose lung cancer screening CT exams with tube current modulation across a range of patient sizes.

Authors:  Anthony J Hardy; Maryam Bostani; Kyle McMillan; Maria Zankl; Cynthia McCollough; Chris Cagnon; Michael McNitt-Gray
Journal:  Med Phys       Date:  2018-09-24       Impact factor: 4.071

5.  Estimating organ doses from tube current modulated CT examinations using a generalized linear model.

Authors:  Maryam Bostani; Kyle McMillan; Peiyun Lu; Grace Hyun J Kim; Dianna Cody; Gary Arbique; S Bruce Greenberg; John J DeMarco; Chris H Cagnon; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

6.  Patient-level dose monitoring in computed tomography: tracking cumulative dose from multiple multi-sequence exams with tube current modulation in children.

Authors:  Azadeh Tabari; Xinhua Li; Kai Yang; Bob Liu; Michael S Gee; Sjirk J Westra
Journal:  Pediatr Radiol       Date:  2021-09-17

7.  iPhantom: A Framework for Automated Creation of Individualized Computational Phantoms and Its Application to CT Organ Dosimetry.

Authors:  Wanyi Fu; Shobhit Sharma; Ehsan Abadi; Alexandros-Stavros Iliopoulos; Qi Wang; Joseph Y Lo; Xiaobai Sun; William P Segars; Ehsan Samei
Journal:  IEEE J Biomed Health Inform       Date:  2021-08-05       Impact factor: 7.021

8.  Comparison of 12 surrogates to characterize CT radiation risk across a clinical population.

Authors:  Francesco Ria; Wanyi Fu; Jocelyn Hoye; W Paul Segars; Anuj J Kapadia; Ehsan Samei
Journal:  Eur Radiol       Date:  2021-02-23       Impact factor: 5.315

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.