| Literature DB >> 27119758 |
Valdey Suedam1, Rafael Tobias Moretti Neto2, Edson Antonio Capello Sousa3, José Henrique Rubo4.
Abstract
Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy's framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27119758 PMCID: PMC4836917 DOI: 10.1590/1678-775720150297
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Figure 1Positioning of the loading application point for application of the static 300 N load in the framework
Final mean and standard deviation of deformation values for each strain gauge with CoCr and PdAg alloys framework in tree conditions of load application (in mɛ)
| Implants | 1 | 2 | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Stain gauges | D1 | L1 | M1 | B1 | D2 | L2 | M2 | B2 | |
| 5 mm | -2181.89 | -2004.14 | -178.39 | 398.77 | -343.7 | -2276.29 | 1118.65 | -17.51 | |
| Group CoCr | ±215.48 | ±459.63 | ±72.39 | ±99.60 | ±109.99 | ±485.69 | ±1874.19 | ±66.37 | |
| 10 mm | -3113.64 | -3160.51 | -633.56 | 547.47 | -215.146 | -3885.74 | 90.39 | -163.74 | |
| ±70.00 | ±93.10 | ±77.28 | ±7.08 | ±65.30 | ±240.98 | ±9.50 | ±53.17 | ||
| 15 mm | -4302.05 | -5538.95 | -773.88 | 1018.86 | -43.17 | -6003.71 | 120.29 | -252.24 | |
| ±81.58 | ±101.36 | ±80.82 | ±114.05 | ±26.09 | ±250.94 | ±9.80 | ±46.24 | ||
| 5 mm | -1397.19 | -1704.65 | 56.28 | 1231.87 | -33.97 | -1963.47 | 118.02 | -112.62 | |
| Group PdAg | ±35.68 | ±119.33 | ±14.21 | ±14.56 | ±12.11 | ±56.90 | ±39.03 | ±16.90 | |
| 10 mm | -2180.87 | -2400.27 | -102.24 | 1351.35 | 11.29 | -3364.77 | 138.38 | -183.15 | |
| ±62.86 | ±113.45 | ±13.25 | ±83.30 | ±33.72 | ±139.45 | ±8.36 | ±9.34 | ||
| 15 mm | -3960.32 | -5034.83 | 419.63 | 2009.83 | 25.42 | -5019.2 | 127.31 | -249.93 | |
| ±56.65 | ±271.49 | ±47.96 | ±52.13 | ±7.56 | ±312.71 | ±16.73 | ±16.01 | ||
Figure 2Graphic of the deformation means captured by the strain gauges in CoCr and PdAg alloy groups
Tukey test for comparisons between groups and Pearson correlation test (distance X deformation) for each group
| Implants | 1 | 2 | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Stain gauges | D1 | L1 | M1 | B1 | D2 | L2 | M2 | B2 | |
| CoCr x PdAg | 5 mm | 0.000247* | 0.196314 | 0.000296* | 0.000223* | 0.000433* | 0.190638 | 0.266985 | 0.014714* |
| 10 mm | 0.000223* | 0.000223* | 0.000223* | 0.000223* | 0.000318* | 0.003219* | 0.000237* | 0.445044 | |
| 15 mm | 0.000260* | 0.004769* | 0.000223* | 0.000223* | 0.000660* | 0.000754* | 0.441627 | 0.9187 | |
| CoCr | DISTANCE x DEFORMATION | -0.9875 | -0.967 | -0.9232 | 0.9183 | 0.8741 | -0.9772 | -0.3776 | -0.8797 |
| p value | 0.000* | 0.000* | 0.000* | 0.000* | 0.000* | 0.000* | 0.165 | 0.000* | |
| PdAg | DISTANCE x DEFORMATION | -0.9748 | -0.9417 | 0.674 | 0.9182 | 0.767 | -0.9887 | 0.1591 | -0.9742 |
| p value | 0.000* | 0.000* | 0.006* | 0.000* | 0.001* | 0.000* | 0.571 | 0.000* | |
* statistically significant difference for p<0.05
Figure 3Strain diagrams with score label for group CoCr-15mm (a) and PdAg-15mm (b)