Literature DB >> 9484066

Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis.

A Sertgöz1.   

Abstract

This study used three-dimensional finite element analysis to investigate the effect of three different occlusal surface materials (resin, resin composite, and porcelain) and four different framework materials (gold, silver-palladium, cobalt-chromium, titanium alloys) on the stress distribution in a six-implant-supported mandibular fixed prosthesis and surrounding bone. A total of 172 N vertical load was distributed over the entire occlusal surface of the finite element model. Generated stress values were calculated in the occlusal surface material, framework, prosthesis retaining screws, implants, and surrounding cortical and spongy bones. The results obtained demonstrated that using a prosthesis superstructure material with a lower elastic modulus (1) did not lead to substantial differences in stress patterns nor in values at the cortical and spongy bones surrounding the implants; and (2) concentrated stresses in the retaining screws for the prosthesis and thus increased the potential risk of prosthesis failure. For the single loading condition investigated, the optimal combination of materials was found to be cobalt-chromium for the framework and porcelain for the occlusal surface.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9484066

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  14 in total

1.  Angulated abutments and perimplants stress: F.E.M. analysis.

Authors:  P Cardelli; M Montani; M Gallio; M Biancolini; C Brutti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2009-12-10

2.  Peri-implant bone reactions around immediately loaded conical implants with different prosthetic suprastructures: histological and histomorphometrical study on minipigs.

Authors:  Bartolomeo Assenza; Antonio Scarano; Vittoria Perrotti; Iole Vozza; Alessandro Quaranta; Manlio Quaranta; Adriano Piattelli; Giovanna Iezzi
Journal:  Clin Oral Investig       Date:  2009-06-04       Impact factor: 3.573

3.  Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage.

Authors:  Min-Jeong Kim; Sung-Ok Hong
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

4.  Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: A 3D FEA study.

Authors:  Akanksha Mourya; Rajvi Nahar; Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Oral Biol Craniofac Res       Date:  2021-03-16

5.  Finite element analysis of the effect of framework materials at the bone-implant interface in the all-on-four implant system.

Authors:  Kasturi Chandrashekhar Kelkar; Vinaya Bhat; Chethan Hegde
Journal:  Dent Res J (Isfahan)       Date:  2021-02-23

6.  Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses.

Authors:  Byoung-Sup Sohn; Seong-Joo Heo; Jai-Young Koak; Seong-Kyun Kim; Su-Young Lee
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

7.  Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis.

Authors:  Xiaomei Li; Zhizhong Cao; Xiaoqian Qiu; Zhen Tang; Lulu Gong; Dalin Wang
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

8.  Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures.

Authors:  Valdey Suedam; Rafael Tobias Moretti Neto; Edson Antonio Capello Sousa; José Henrique Rubo
Journal:  J Appl Oral Sci       Date:  2016-04       Impact factor: 2.698

9.  Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study.

Authors:  Lamiaa Said Elfadaly; Lamiaa Sayed Khairallah; Mona Atteya Al Agroudy
Journal:  Int J Implant Dent       Date:  2017-07-13

10.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.