Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.

Letícia Borges Jacques1, Márcio Silva Moura, Valdey Suedam, Edson Antonio Capello Souza, José Henrique Rubo.   

Abstract

OBJECTIVES: The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length.
MATERIAL AND METHODS: Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded.
RESULTS: Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions.
CONCLUSION: Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19489929     DOI: 10.1111/j.1600-0501.2009.01712.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Determination of strain around distal implants as abutments for partial and fixed implant-supported prostheses with posterior cantilever.

Authors:  Roodabeh Koodaryan; Neda Yasamineh; Ali Hafezeqoran; Sheida Monem Moharrer; Seyed Gholamreza Noorazar
Journal:  J Adv Pharm Technol Res       Date:  2022-04-07

2.  Effect of veneering material on the deformation suffered by implant-supported fixed prosthesis framework.

Authors:  Antônio Francisco Grando; Carlos Eduardo Edwards Rezende; Edson Antônio Capello Sousa; José Henrique Rubo
Journal:  J Appl Oral Sci       Date:  2014-06       Impact factor: 2.698

3.  Effect of the number of abutments on biomechanics of Branemark prosthesis with straight and tilted distal implants.

Authors:  Marcos Michelon Naconecy; Tomás Geremia; André Cervieri; Eduardo Rolim Teixeira; Rosemary Sadami Shinkai
Journal:  J Appl Oral Sci       Date:  2010 Mar-Apr       Impact factor: 2.698

4.  Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures.

Authors:  Valdey Suedam; Rafael Tobias Moretti Neto; Edson Antonio Capello Sousa; José Henrique Rubo
Journal:  J Appl Oral Sci       Date:  2016-04       Impact factor: 2.698

  4 in total