Inaccurate fit of implant superstructures. Part 1: Stresses generated on the superstructure relative to the size of fit discrepancy.

N D Millington1, T Leung.   

Abstract

This laboratory study used a photoelastic-coating technique to investigate the relationship between the magnitude and location of discrepancies of fit and the amount and distribution of surface stresses on an implant superstructure. For the test superstructure involving four abutments and a single fit discrepancy, maximum surface stress was found over the intermediate abutment, regardless of the location of the fit error. The results show a positive relationship between the size of the fit discrepancy and the magnitude of stress on the superstructure for gaps of up to 104 micrometers at an end abutment and 55 micrometers at an intermediate abutment, when the gold screws were tightened at 10-Ncm torque.

Entities:  

Mesh:

Year:  1995        PMID: 8595110

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

1.  Influence of prosthetic screw material on joint stability in passive and non-passive implant-supported dentures.

Authors:  Aloísio Oro Spazzin; Guilherme Elias Pessanha Henriques; Mauro Antônio de Arruda Nóbilo; Rafael Leonardo Xediek Consani; Lourenço Correr-Sobrinho; Marcelo Ferraz Mesquita
Journal:  Open Dent J       Date:  2009-12-30

2.  Techniques for evaluating the fit of removable and fixed prosthesis.

Authors:  Mallika S Shetty; K Kamalakanth Shenoy
Journal:  ISRN Dent       Date:  2011-07-14

3.  Accuracy of five implant impression technique: effect of splinting materials and methods.

Authors:  Sang-Jik Lee; Sung-Bum Cho
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

4.  Deformation of the Internal Connection of Narrow Implants after Insertion in Dense Bone: An in Vitro Study.

Authors:  Rafael Delgado-Ruiz; Ana Nicolas Silvente; Georgios Romanos
Journal:  Materials (Basel)       Date:  2019-06-06       Impact factor: 3.623

5.  Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures.

Authors:  Valdey Suedam; Rafael Tobias Moretti Neto; Edson Antonio Capello Sousa; José Henrique Rubo
Journal:  J Appl Oral Sci       Date:  2016-04       Impact factor: 2.698

6.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.