Literature DB >> 27110051

Nonlinear Statistical Reconstruction for Flat-Panel Cone-Beam CT with Blur and Correlated Noise Models.

Steven Tilley1, Jeffrey H Siewerdsen1, Wojciech Zbijewski1, J Webster Stayman1.   

Abstract

Flat-panel cone-beam CT (FP-CBCT) is a promising imaging modality, partly due to its potential for high spatial resolution reconstructions in relatively compact scanners. Despite this potential, FP-CBCT can face difficulty resolving important fine scale structures (e.g, trabecular details in dedicated extremities scanners and microcalcifications in dedicated CBCT mammography). Model-based methods offer one opportunity to improve high-resolution performance without any hardware changes. Previous work, based on a linearized forward model, demonstrated improved performance when both system blur and spatial correlations characteristics of FP-CBCT systems are modeled. Unfortunately, the linearized model relies on a staged processing approach that complicates tuning parameter selection and can limit the finest achievable spatial resolution. In this work, we present an alternative scheme that leverages a full nonlinear forward model with both system blur and spatially correlated noise. A likelihood-based objective function is derived from this forward model and we derive an iterative optimization algorithm for its solution. The proposed approach is evaluated in simulation studies using a digital extremities phantom and resolution-noise trade-offs are quantitatively evaluated. The correlated nonlinear model outperformed both the uncorrelated nonlinear model and the staged linearized technique with up to a 86% reduction in variance at matched spatial resolution. Additionally, the nonlinear models could achieve finer spatial resolution (correlated: 0.10 mm, uncorrelated: 0.11 mm) than the linear correlated model (0.15 mm), and traditional FDK (0.40 mm). This suggests the proposed nonlinear approach may be an important tool in improving performance for high-resolution clinical applications.

Entities:  

Year:  2016        PMID: 27110051      PMCID: PMC4837455          DOI: 10.1117/12.2216126

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  9 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Maximum-likelihood transmission image reconstruction for overlapping transmission beams.

Authors:  D F Yu; J A Fessler; E P Ficaro
Journal:  IEEE Trans Med Imaging       Date:  2000-11       Impact factor: 10.048

3.  Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT.

Authors:  Bing Feng; Jeffrey A Fessler; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

4.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

5.  Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner.

Authors:  Alexander L C Kwan; John M Boone; Kai Yang; Shih-Ying Huang
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

6.  Iterative CT Reconstruction using Models of Source and Detector Blur and Correlated Noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2014

7.  Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT.

Authors:  Hua Zhang; Luo Ouyang; Jianhua Ma; Jing Huang; Wufan Chen; Jing Wang
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

8.  A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization.

Authors:  W Zbijewski; P De Jean; P Prakash; Y Ding; J W Stayman; N Packard; R Senn; D Yang; J Yorkston; A Machado; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

9.  Combining ordered subsets and momentum for accelerated X-ray CT image reconstruction.

Authors:  Donghwan Kim; Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-08-22       Impact factor: 10.048

  9 in total
  2 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Detector Blur and Correlated Noise Modeling for Digital Breast Tomosynthesis Reconstruction.

Authors:  Jiabei Zheng; Jeffrey A Fessler; Heang-Ping Chan
Journal:  IEEE Trans Med Imaging       Date:  2017-07-27       Impact factor: 10.048

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.