Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner.

Alexander L C Kwan1, John M Boone, Kai Yang, Shih-Ying Huang.   

Abstract

The purpose of this study was to examine the spatial resolution of a prototype pendant-geometry cone-beam breast computed tomography (CT) system. Modulation transfer functions (MTFs) of the reconstructed image in the coronal (x and y) plane were computed as a function of the cone angle, the radial distance from the axis of rotation, the size of the reconstruction matrix, the back-projection filter used, and the number of projections acquired for the reconstruction. The results show that the cone angle and size of the reconstruction matrix have minimal impact on the MTF, while the MTF degraded radially from the axis of rotation (from 0.76 at 2.6 mm from axis of rotation down to 0.37 at 76.9 mm from axis of rotation at f=0.5 mm(-1)). The Ramp reconstruction filter increases the MTF near the axis of rotation relative to the Shepp-Logan filter, while an increase in the number of projections from 500 to 1000 increased the MTF near the periphery of the reconstructed image. The MTF in the z direction (anterior-posterior direction) was also evaluated. The z-direction MTF values tend to be higher when compared to the coronal MTF (0.85 at f =0.5 mm(-1)), and tend to be very constant throughout the coronal plane direction. The results suggest that an increase in the MTF for the prototype breast CT system is possible by optimizing various scanning and reconstruction parameters.

Entities:  

Mesh:

Year:  2007        PMID: 17278513     DOI: 10.1118/1.2400830

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  45 in total

1.  The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure.

Authors:  Willy Tjong; Galateia J Kazakia; Andrew J Burghardt; Sharmila Majumdar
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Computer modeling of the spatial resolution properties of a dedicated breast CT system.

Authors:  Kai Yang; Alexander L C Kwan; John M Boone
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

3.  A local shift-variant Fourier model and experimental validation of circular cone-beam computed tomography artifacts.

Authors:  Steven Bartolac; Roll Clackdoyle; Frederic Noo; Jeff Siewerdsen; Douglas Moseley; David Jaffray
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

Review 4.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Noise power properties of a cone-beam CT system for breast cancer detection.

Authors:  Kai Yang; Alexander L C Kwan; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

6.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

7.  Modulation transfer function evaluation of cone beam computed tomography for dental use with the oversampling method.

Authors:  H Watanabe; E Honda; T Kurabayashi
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

Review 8.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 9.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

10.  An X-Ray computed tomography/positron emission tomography system designed specifically for breast imaging.

Authors:  John M Boone; Kai Yang; George W Burkett; Nathan J Packard; Shih-ying Huang; Spencer Bowen; Ramsey D Badawi; Karen K Lindfors
Journal:  Technol Cancer Res Treat       Date:  2010-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.