Literature DB >> 31893263

A Micromachined Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystal Composite Circular Array for Intravascular Ultrasound Imaging.

Sibo Li1, Jian Tian2, Xiaoning Jiang1.   

Abstract

This paper describes the design, fabrication, and characterization of a micromachined high-frequency Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) single crystal/epoxy 1-3 composite ultrasound circular array. The 1-3 composites were fabricated by deep reactive ion etching (DRIE) of PMN-PT single crystal. The feature size of single crystal pillars was 18 μm in diameter. The kerf between pillars was less than 4 μm. A 50-element circular array transducer (radially outward) with the pitch of 100 μm was wrapped around a needle resulting in an outer diameter of 1.7 mm. The array test showed that the center frequency reached 39±2 MHz and -6-dB fractional bandwidth was 82±6%. The insertion loss was -41 dB, and crosstalk between adjacent elements was -24 dB. A radial outward imaging testing with phantom wires (D = 50 μm) was conducted. The image was in a dynamic range of 30 dB to show a penetration depth of 6 mm by using the synthetic aperture method. The -6-dB beam width was estimated to be 60 μm in the axial direction at 3.1 mm distance away from the probe. The results suggest that the 40 MHz micromachined 1-3 composite circular array is promising for intravascular ultrasound (IVUS) imaging applications.

Entities:  

Year:  2019        PMID: 31893263      PMCID: PMC6938393          DOI: 10.1115/1.4041443

Source DB:  PubMed          Journal:  J Eng Sci Med Diagn Ther        ISSN: 2572-7966


  24 in total

Review 1.  American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.

Authors:  G S Mintz; S E Nissen; W D Anderson; S R Bailey; R Erbel; P J Fitzgerald; F J Pinto; K Rosenfield; R J Siegel; E M Tuzcu; P G Yock
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

2.  A 30-MHz piezo-composite ultrasound array for medical imaging applications.

Authors:  Timothy A Ritter; Thomas R Shrout; Rick Tutwiler; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-02       Impact factor: 2.725

3.  Development of a 35-MHz piezo-composite ultrasound array for medical imaging.

Authors:  Jonathan M Cannata; Jay A Williams; Qifa Zhou; Timothy A Ritter; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-01       Impact factor: 2.725

4.  Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging.

Authors:  M O'Donnell; L J Thomas
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

5.  Fabrication and performance of a miniaturized 64-element high-frequency endoscopic phased array.

Authors:  Andre Bezanson; Rob Adamson; Jeremy Brown
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

6.  Advantages and Challenges of Relaxor-PbTiO3 Ferroelectric Crystals for Electroacoustic Transducers- A Review.

Authors:  Shujun Zhang; Fei Li; Xiaoning Jiang; Jinwook Kim; Jun Luo; Xuecang Geng
Journal:  Prog Mater Sci       Date:  2015-03-01

7.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

8.  Micromachining techniques in developing high-frequency piezoelectric composite ultrasonic array transducers.

Authors:  Changgeng Liu; Frank T Djuth; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-12       Impact factor: 2.725

9.  Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.

Authors:  Xiang Li; Teng Ma; Jian Tian; Pengdi Han; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

10.  High-Frequency Ultrasound Array Designed for Ultrasound-Guided Breast Biopsy.

Authors:  Thomas Cummins; Payam Eliahoo; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-31       Impact factor: 2.725

View more
  1 in total

Review 1.  Recent Advances in Transducers for Intravascular Ultrasound (IVUS) Imaging.

Authors:  Chang Peng; Huaiyu Wu; Seungsoo Kim; Xuming Dai; Xiaoning Jiang
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.847

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.