Literature DB >> 30571620

Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.

Evren Fatih Arkan, F Levent Degertekin.   

Abstract

High-frequency ultrasound imaging arrays are important for a broad range of applications, from small animal imaging to photoacoustics. Capacitive micromachined ultrasonic transducer (CMUT) arrays are particularly attractive for these applications as low noise receiver electronics can be integrated for an overall improved performance. In this paper, we present a comprehensive analysis of high-frequency CMUT arrays based on an experimentally verified CMUT array simulation tool. The results obtained on an example, a 40-MHz 1-D CMUT array for intravascular imaging, are used to obtain key design insights and tradeoffs for receive only and pulse-echo imaging. For the receiver side, thermal mechanical current noise, plane wave pressure sensitivity, and pressure noise spectrum are extracted from simulations. Using these parameters, we find that the receiver performance of CMUT arrays can be close to an ideal piston, independent of gap thickness, and applied dc bias, when coupled to low noise electronics with arrays utilizing smaller membranes performing better. For pulse-echo imaging, thermal mechanical current noise limited signal-to-noise ratio is observed to be dependent on the maximum available voltage and gap thickness. In terms of bandwidth, we find that the Bragg resonance of the array, related to the fill factor, is a significant determinant of the high frequency limit and the fluid loaded single membrane resonance determines the lower limit. Based on these results, we present design guidelines requiring only fluid loaded single membrane simulations and membrane pitch to achieve a desired pulse-echo response. We also provide a design example and discuss limitations of the approach.

Entities:  

Mesh:

Year:  2018        PMID: 30571620      PMCID: PMC6415772          DOI: 10.1109/TUFFC.2018.2887043

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  36 in total

1.  A new 15-50 MHz array-based micro-ultrasound scanner for preclinical imaging.

Authors:  F Stuart Foster; James Mehi; Marc Lukacs; Desmond Hirson; Chris White; Chris Chaggares; Andrew Needles
Journal:  Ultrasound Med Biol       Date:  2009-08-03       Impact factor: 2.998

2.  Intravascular photoacoustic imaging at 35 and 80 MHz.

Authors:  Xiang Li; Wei Wei; Qifa Zhou; K Kirk Shung; Zhongping Chen
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

3.  Equivalent circuit-based analysis of CMUT cell dynamics in arrays.

Authors:  H K Oguz; Abdullah Atalar; Hayrettin Köymen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-05       Impact factor: 2.725

4.  Efficient Broadband Simulation of Fluid-Structure Coupling for Membrane-Type Acoustic Transducer Arrays Using the Multilevel Fast Multipole Algorithm.

Authors:  Bernard Shieh; Karim G Sabra; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

5.  Micro-machined high-frequency (80 MHz) PZT thick film linear arrays.

Authors:  Qifa Zhou; Dawei Wu; Changgeng Liu; Benpeng Zhu; Frank Djuth; K Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-10       Impact factor: 2.725

6.  Toward a reduced-wire readout system for ultrasound imaging.

Authors:  Jaemyung Lim; Evren F Arkan; F Levent Degertekin; Maysam Ghovanloo
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

7.  Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

Authors:  Nhat Quang Bui; Kyu Kyu Hlaing; Van Phuc Nguyen; Trung Hau Nguyen; Yun-Ok Oh; Xiao Feng Fan; Yong Wook Lee; Seung Yun Nam; Hyun Wook Kang; Junghwan Oh
Journal:  Comput Med Imaging Graph       Date:  2015-07-22       Impact factor: 4.790

8.  High frequency ultrasonography: a complementary diagnostic method in evaluation of primary cutaneous melanoma.

Authors:  M Maj; O Warszawik-Hendzel; E Szymanska; I Walecka; A Rakowska; M Antczak-Marczak; P Kuna; J Kruszewski; A Nasierowska-Guttmejer; J Litniewski; A Nowicki; M Olszewska; L Rudnicka
Journal:  G Ital Dermatol Venereol       Date:  2015-10       Impact factor: 2.011

9.  Surface micromachined capacitive ultrasonic transducers.

Authors:  I Ladabaum; X Jin; H T Soh; A Atalar; B T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

10.  High-Frequency Ultrasound Array Designed for Ultrasound-Guided Breast Biopsy.

Authors:  Thomas Cummins; Payam Eliahoo; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-31       Impact factor: 2.725

View more
  3 in total

1.  Highly Integrated Guidewire Ultrasound Imaging System-on-a-Chip.

Authors:  Jaemyung Lim; Coskun Tekes; Evren F Arkan; Ahmad Rezvanitabar; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE J Solid-State Circuits       Date:  2020-01-30       Impact factor: 5.013

Review 2.  Circuits on miniaturized ultrasound imaging system-on-a-chip: a review.

Authors:  Jaemyung Lim
Journal:  Biomed Eng Lett       Date:  2022-05-12

3.  Analysis of Negative Capacitance-Based Broadband Impedance Matching for CMUTs.

Authors:  Ahmad Rezvanitabar; Evren F Arkan; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-08-27       Impact factor: 3.267

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.