Abstract

OBJECTIVE: The intraoperative Iso-C C-arm (Siremobil Iso-C 3D; Siemens Medical Solutions, Erlangen, Germany) provides a unique ability to acquire and view multiplanar three-dimensional images of intraoperative anatomy. Registration for intraoperative surgical navigation may be automated, thus simplifying the operative workflow.
METHODS: Iso-C C-arm intraoperative fluoroscopy acquires 100 images, each of which must be 1.8 degrees in a circumferential fashion about an "isocentric" point in space. The system generates a high-resolution isotropic three-dimensional data set that is available immediately after the 90-second C-arm rotation. The data set is ported to the image-guided workstation, registration is immediate and automated, and the surgeon can navigate with millimetric accuracy. The authors prospectively examined data from the initial 60 patients examined with the Iso-C, among whom were cases of anterior and posterior spinal instrumentation from the occiput to the sacrum. Percutaneous and minimally invasive spinal and cranial procedures were also included.
RESULTS: Automated registration for image-guided navigation was attainable for anterior and posterior cases from the cranial base and entire spine. In most cases, intraoperative postprocedural imaging with the Iso-C mitigated the need for postoperative imaging.
CONCLUSION: Intraoperative Iso-C three-dimensional scanning allows real-time feedback during cranial base and spinal surgery and during procedures involving instrumentation. In most cases, it obviates the need for postoperative computed tomography. Its usefulness is in its simplicity, and it can be easily adapted to the operating room workflow. When coupled with intraoperative navigation, this new technology facilitates complex neurosurgical procedures by improving the accuracy, safety, and time of surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15113467     DOI: 10.1227/01.neu.0000119755.71141.13

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  22 in total

1.  Device setting modifications for 3D flatpanel imaging in skull base surgery.

Authors:  Frederike Hassepass; Wolfgang Maier; Antje Aschendorff; Stefan Bulla; Werner Vach; Roland Laszig; Tanja D Grauvogel
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-04-06       Impact factor: 2.503

2.  3D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screws.

Authors:  J-S Jarvers; S Katscher; A Franck; S Glasmacher; C Schmidt; T Blattert; C Josten
Journal:  Eur J Trauma Emerg Surg       Date:  2011-04-01       Impact factor: 3.693

3.  Calibration of mobile-gantry computed tomography for surgical navigation.

Authors:  Anna Belkova; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-08       Impact factor: 2.924

4.  Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance.

Authors:  Eric W Nottmeier; Andrew B Foy
Journal:  Eur Spine J       Date:  2007-11-22       Impact factor: 3.134

Review 5.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

6.  Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation.

Authors:  Erin J Smith; Hisham A Al-Sanawi; Braden Gammon; Paul J St John; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-25       Impact factor: 2.924

Review 7.  An endoscopic surgical technique for treating radiculopathy secondary to S1 nerve compression from a pedicle screw: technical note.

Authors:  Ralf Wagner; Albert E Telfeian
Journal:  J Spine Surg       Date:  2018-12

8.  Augmented reality surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study.

Authors:  Longfei Ma; Zhe Zhao; Fang Chen; Boyu Zhang; Ligong Fu; Hongen Liao
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-08-05       Impact factor: 2.924

9.  Enhancement of bone shadow region using local phase-based ultrasound transmission maps.

Authors:  Ilker Hacihaliloglu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-11       Impact factor: 2.924

10.  Ultrasound imaging and segmentation of bone surfaces: A review.

Authors:  Ilker Hacihaliloglu
Journal:  Technology (Singap World Sci)       Date:  2017-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.