Literature DB >> 27027239

Estimation of the risk of secondary malignancy arising from whole-breast irradiation: comparison of five radiotherapy modalities, including TomoHDA.

Eun Young Han1, Nava Paudel2, Jiwon Sung3, Myonggeun Yoon3, Weon Kuu Chung4, Dong Wook Kim4.   

Abstract

The risk of secondary cancer from radiation treatment remains a concern for long-term breast cancer survivors, especially those treated with radiation at the age younger than 45 years. Treatment modalities optimally maximize the dose delivery to the tumor while minimizing radiation doses to neighboring organs, which can lead to secondary cancers. A new TomoTherapy treatment machine, TomoHDATM, can treat an entire breast with two static but intensity-modulated beams in a slice-by-slice fashion. This feature could reduce scattered and leakage radiation doses. We compared the plan quality and lifetime attributable risk (LAR) of a second malignancy among five treatment modalities: three-dimensional conformal radiation therapy, field-in-field forward-planned intensity-modulated radiation therapy, inverse-planned intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, and TomoDirect mode on the TomoHDA system. Ten breast cancer patients were selected for retrospective analysis. Organ equivalent doses, plan characteristics, and LARs were compared. Out-of-field organ doses were measured with radio-photoluminescence glass dosimeters. Although the IMRT plan provided overall better plan quality, including the lowest probability of pneumonitis, it caused the second highest LAR. The TomoTherapy plan provided plan quality comparable to the IMRT plan and posed the lowest total LAR to neighboring organs. Therefore, it can be a better treatment modality for younger patients who have a longer life expectancy.

Entities:  

Keywords:  IMRT; TomoHDA; VMAT; breast; secondary malignancy

Mesh:

Year:  2016        PMID: 27027239      PMCID: PMC5008415          DOI: 10.18632/oncotarget.8392

Source DB:  PubMed          Journal:  Oncotarget        ISSN: 1949-2553


INTRODUCTION

Evolving early-stage breast cancer treatment strategies have improved the survival of patients who undergo breast conservation surgery. After surgery, patients generally receive radiation treatment of the entire breast with a dose of 50.4 Gy [1]. This strategy reduces local cancer recurrence by one half to two thirds and the chance of death due to breast cancer by about one sixth [2]. However, among >10-year survivors, the probability of developing a secondary malignancy increases significantly in women who receive the radiation treatment at the age of 45 years or younger [3]. To improve these patients' long-term survival and quality of life, minimizing scattered and leakage radiation dose to normal tissues or organs while maintaining tumor control becomes more critical [4]. Various treatment modalities have been applied for breast cancer treatment using a traditional linear accelerator (Linac). Patients can be treated by three-dimensional conformal radiation therapy (3D-CRT), field-in-field forward-planned intensity-modulated radiation therapy (FinF), standard intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). The newly introduced TomoHDATM machine (v2.0, Accuray, Madison, WI, USA) can deliver IMRT beams at static angles in a slice-by-slice fashion while a patient slowly moves into the beam. This treatment modality is called TomoDirectTM (TOMO). Another advanced feature of the TomoHDA system is that two field-defining jaws move dynamically to conform to a target in the craniocaudal direction, which can produce a sharp dose fall-off. Previous comparative studies have shown that the risk of secondary cancer induction is higher with an IMRT plan than with a 3D-CRT plan. This is attributed to increased out-of-field leakage radiation due to the higher number of fields and monitor units (MUs) used in the IMRT plan. But the plan quality of the IMRT plan, with regard to factors such as planning target volume (PTV) dose coverage and organ-at-risk (OAR) dose reductions, is generally better than that of the 3D-CRT plan [5-9]. In a comparative study of oropharyngeal cancer treatment plans, Gestel et al. reported that the helical TomoTherapy plan elicited better homogeneous PTV dose coverage and better OAR sparing than other modalities. However, the lifetime attributable risks (LARs) between treatment modalities were not compared [10]. The purpose of the study described here is to compare the plan quality and LAR among five treatment modalities (3D-CRT, FinF, IMRT, VMAT, and TOMO). Our hypothesis is that the TomoDirect modality (TOMO) can maintain the plan quality of the Linac-based IMRT plan and still lower LAR compared with the other treatment modalities.

MATERIALS AND METHODS

Patient selection and planning parameters

Ten female patients with breast cancer (5 left sided and 5 right sided) were retrospectively selected for this study. As shown in Table 1, PTVs among the ten patients ranged from 291 to 1421 cm3.
Table 1

Patient characteristics

Patient numberBreast siteTangential beam angles (o)PTV volume (cm3)
1Left317.4 / 127.21421
2Left323.6 / 129733
3Left305.9 / 118.8596
4Left319.7 / 127.8291
5Left315.7 / 122.2726
6Right239.3 / 49.1485
7Right235.0 / 38.11025
8Right233.5 / 35866
9Right243.6 / 50904
10Right233.1 / 41381
A CT simulator (Brilliance CT, Philips Medical System, Netherlands) was used to obtain planning CT images with 3 mm slice thickness for patients in supine position with both arms up with an aid of a wing board. TOMO plans for all patients were optimized with the TomoTherapy (v 5.0) planning system, and the Linac-based (21iX Varian Medical System, Palo Alto, CA) plans were optimized with the Eclipse treatment planning system (v 8.9, Varian Medical System, Palo Alto, CA). PTV was defined as the “ipsilateral” breast (the breast containing the tumor) with 5 mm skin extraction. The lungs, heart, and contralateral breast were contoured as OARs. The prescription dose was set to 50.4 Gy in 28 fractions, and the plan was normalized as this dose covering 95% of the PTV. Dose constraints for ipsilateral lung volumes receiving 20 Gy and 10 Gy doses (V20Gy and V10Gy) were set as less than 20% and 40% of the lung volume, respectively. The maximum spinal cord dose was limited to less than 45 Gy [11]. Doses to the other organs were kept as low as possible. For each patient, five different plans were created using the five treatment modalities. Figure 1 shows a graphical view of dose distributions and beam arrangements of the treatment plans. The 3D-CRT plan consisted two parallel opposed tangential beams. The FinF plan has the same gantry angles as the 3D-CRT plan but added sub-fields created by a multi-leaf collimator (MLC) for dose compensation. The IMRT plan consisted as IMRT field can consist any number of beams ∼>5 of 10 to 12 fields to spare the contralateral breast, lung, and heart. Recently, Li et al. reported a non-isocentric IMRT treatment strategy for breast radiation therapy [12], with significant reduction of ipsilateral lung and heart doses; however, this technique takes longer planning and treatment time, instead we generated a single isocentric IMRT plan and increased the number of fields to ensure PTV dose coverage. The range of the gantry angles of the IMRT plans was relatively larger than that of the 3D-CRT plan by ∼ 26.5o ± 9.8o. The VMAT plan consisted of 3 to 4 partial arcs covering a range of beam angles similar to that of the IMRT plan. For the left breast irradiation, the average gantry angle spanned from 305o to 152o, and for the right breast irradiation the average gantry angle spanned from 60o to 214o. For the TOMO plan, a field width of 5.0 cm, a pitch of 0.4, and a maximum modulation factor of 2.067 were used.
Figure 1

Graphical view of the isodose lines in the axial view for the patient 1 corresponding to Table 1 for the

a. three-dimensional conformal radiation therapy (3D-CRT) plan, b. field-in-field forward-planned intensity-modulated radiation (FinF) plan, c. intensity-modulated radiation therapy (IMRT) plan, d. volumetric modulated arc therapy (VMAT) plan, and e. TOMO plan.

In this study, contralateral breast, contralateral and ipsilateral lung, and “contralateral” and “ipsilateral” heart (corresponding to right-sided and left-sided breast cancers, respectively) were considered in-field organs. Six out-of-field organs—thyroid, stomach, liver, colon, gonad, and rectum—were selected and analyzed. Doses to in-field organs were derived from dose-volume histograms (DVHs), and doses to out-of-field organs were derived from measurements using a radio-photoluminescence glass dosimeter (RPLGD).

Graphical view of the isodose lines in the axial view for the patient 1 corresponding to Table 1 for the

a. three-dimensional conformal radiation therapy (3D-CRT) plan, b. field-in-field forward-planned intensity-modulated radiation (FinF) plan, c. intensity-modulated radiation therapy (IMRT) plan, d. volumetric modulated arc therapy (VMAT) plan, and e. TOMO plan.

Out-of-field organ dose measurement using a radio-photoluminescence glass dosimeter

Out-of-field dosimetry requires a direct measurement as commercial treatment planning systems cannot estimate dose outside the radiation field well [13, 14]. We used RPLGD dosimeters (A.T.G., Chiyoda Technology Corporation, Tokyo, Japan) to estimate the out-of-field organ doses. RPLGD has good reproducibility and low energy dependency at energy levels > 200 keV [15, 16]. Small differences in individual sensitivity, repeatable readout, and excellent accuracy and stability at room temperature make RPLGD suitable for the dosimetry of scattered radiation outside the treatment field [17, 18]. Rah et al. reported that the reproducibility, fading effect, and angular dependency of RPLGD with a 6 MV photon beam were 0.9%, 1.7%, and 1.0%, respectively [19, 20]. All patient plans were delivered on an anthropomorphic RANDO female phantom (The Phantom Laboratory, Salem, NY) including two breasts (10.8 cm in diameter and 4.3 cm in height) attached to a bottom plate, and organ doses were collected with detectors placed in the approximate middle of each organ. A total dose of 10 Gy was delivered due to limited sensitivity of RPLGD to scattered radiation. The average dose measured by the detectors was considered the organ equivalent dose (OED). Figure 2 displays detector positions in out-of-field organs in the female RANDO phantom, including the numbers of RPLGDs in parentheses.
Figure 2

Detector positions in out-of-field organs (with numbers of RPLGDs in parentheses) in the female RANDO phantom

In-field organ doses based on dose-volume histograms

Dosimetry for in-field organs (ipsilateral and contralateral lung, ipsilateral or contralateral heart, and contralateral breast) was based on the DVHs of each plan. The homogeneity index (HI), coverage index (CVI), and conformity index (CI) of the PTV and doses to lungs and heart were compared by treatment modality [21]. HI represents dose uniformity, defined as HI = (|D2 - D98|/Rx) × 100, where D2 and D98 are the doses received by 2% and 98%, respectively, of the PTV in the DVH and Rx is the prescription dose [22]. By definition, smaller values of HI give better dose homogeneity in the PTV. CVI is defined as CVI = V100/V, where V100 is a volume receiving 100% of the prescription dose, and V is a volume of PTV [22]. CI is defined as CI = (V95, where V95 is the PTV volume receiving 95% of the prescription dose, and V95 is the body volume receiving 95% of the prescription dose [23]. In addition, the ipsilateral lung volumes receiving 20 Gy (V20Gy) and 10 Gy (V10Gy) are considered important parameters for evaluating the probability of pneumonitis [24-28]. We used the plateau dose-response model to estimate an OED for normal organs as follows [29, 30]. where V is a body volume, and V is a volume element exposed to a dose element D [31]. In this model, a parameter δ was used to determine a dose-response curve for a specific organ. The OED values were used to estimate the LAR to each organ.

Estimation of lifetime attributable risk to radiation dose

As in the BEIR VII: Health Risks from Exposure to Low Levels of Ionizing Radiation report [32], the LAR for a person exposed to a radiation dose (D) at age (e) is expressed as follows: where ERR and EAR are an excess relative risk and an excess absolute risk, respectively, attained at the age of a as a result of the radiation exposure at the age of λCI i is the baseline cancer incidence rate and w is the weight. S(a)/S(e) is a ratio of the probability of surviving at the ages of a and e, and L is the latent period (5 years) for solid tumors. A weight (w) of 0.7 is encouraged by the BEIR Committee for most organs, although exceptions include breasts and lungs. For breasts, only the EAR model is recommended, and for lungs, a weight of 0.3 is recommended. The EAR and ERR model of BEIR VII are functions of sex (x), age at exposure (e), and attained age (a) as defined by the following equation: where β, γ, and η are model parameters for the age of exposure (e) and the attained age (a). Table 2 shows the parameters for preferred risk models in the BEIR VII report. In this study, we summed the age from e + L to 100 years in LAR calculations for consistency with data from International Commission on Radiological Protection (ICRP) Report 103 [33].
Table 2

Parameters for preferred risk models in the BEIR VII: Health Risks from Exposure to Low Levels of Ionizing Radiation report

SiteERR modelEAR Model
βMβFγηβMβFγη
Lung0.321.4−0.3−1.42.33.4−0.415.2
Breast (a<50)Not used9.4−0.513.5
Breast (a>=50))9.4−0.511.1
Thyroid0.531.05−0.830Not used
Liver0.320.32−0.3−1.42.21−0.414.1
Stomach0.210.48−0.3−1.44.94.9−0.412.8
Colon0.630.43−0.3−1.43.21.6−0.412.8
Gonad0.270.45−0.3−2.86.24.8−0.412.8
Rectum0.630.43−0.3−1.43.21.6−0.412.8

RESULTS AND DISCUSSION

Comparison of the organ equivalent doses of the five treatment modalities

Plan statistics for our 10 patients generated using the five treatment modalities are tabulated in Table 3. While the TOMO plans produced better dose homogeneity in the PTV, the IMRT and VMAT plans produced better PTV dose coverage and dose conformity. The V20Gy of the ipsilateral lung was the lowest in the IMRT plan, followed by the VMAT, 3D-CRT, TOMO, and FinF plans. However, The V10Gy was the highest for the VMAT plan among the five modalities. Therefore the IMRT plan produced the least probability of radiation-induced pneumonitis.
Table 3

Patient plan information and findings (mean ± standard deviation) for the five modalities

RegionSiteItem3D-CRTFinFIMRTVMATTOMO
No. of fields/arcs2210 to 123 to 42 to 4
Monitor units per fraction229 ± 13220 ± 111479 ± 271460 ± 512807 ± 655
In fieldPTV coverageHI13.02 ± 1.7811.74 ± 2.2910.62 ± 2.1811.41 ± 1.836.67 ± 2.81
CVI1.44 ± 0.181.41 ± 0.251.13 ± 0.061.10 ± 0.081.34 ± 0.16
CI0.60 ± 0.090.62 ± 0.100.82 ± 0.030.83 ± 0.040.51 ± 0.08
Ipsilateral lungV10a16.88 ± 5.6517.50 ± 6.8211.66 ± 4.7329.32 ± 10.0217.18 ± 6.19
V20a12.93 ± 5.1513.48 ± 6.276.97 ± 3.598.98 ± 5.1713.42 ± 5.68
Ipsilateral lungOEDb2.42 ± 0.442.49 ± 0.432.33 ± 0.644.69 ± 0.872.26 ± 0.40
Contralateral lungOED0.21 ± 0.120.20 ± 0.100.20 ± 0.101.23 ± 1.050.25 ± 0.07
Ipsilateral heartOED1.77 ± 0.621.86 ± 0.631.42 ± 0.524.77 ± 0.751.99 ± 0.65
Contralateral heartOED0.78 ± 0.580.69 ± 0.210.50 ± 0.082.59 ± 1.110.62 ± 0.13
Contralateral breastOED0.35 ± 0.130.38 ± 0.140.29 ± 0.181.31 ± 0.550.31 ± 0.07
Out of fieldThyroidOED0.38 ± 0.130.37 ± 0.140.65 ± 0.210.76 ± 0.430.19 ± 0.04
LiverOED0.45 ± 0.170.47 ± 0.160.65 ± 0.130.86 ± 0.390.36 ± 0.10
StomachOED0.45 ± 0.210.48 ± 0.200.65 ± 0.130.72 ± 0.180.25 ± 0.07
ColonOED0.14 ± 0.030.16 ± 0.090.49 ± 0.130.30 ± 0.100.15 ± 0.02
GonadOED0.03 ± 0.010.04 ± 0.010.15 ± 0.050.10 ± 0.020.06 ± 0.01
RectumOED0.02 ± 0.010.02 ± 0.010.10 ± 0.030.06 ± 0.010.05 ± 0.01

Percentage of treatment volume that received 10 Gy or 20 Gy.

Organ equivalent dose (in Gy).

Percentage of treatment volume that received 10 Gy or 20 Gy. Organ equivalent dose (in Gy). As shown in Figure 3, the OEDs in in-field organs were the highest with the VMAT plans. Most in-field OEDs were the lowest with the IMRT plans, but the out-of-field OEDs for IMRT were higher than those for the 3D-CRT, FinF, and TOMO plans. The average number of MUs of the IMRT plans was 7 times that of the 3D-CRT plans. This large MU value was caused by the high modulation of MLCs. This high modulation with IMRT possibly caused the higher dose for out-of-field OARs such as the colon, gonad, and rectum as shown as Table 3.
Figure 3

OEDs of in-field and out-of-field organs for the five treatment modalities

Even though the VMAT plan used lower MUs as compared to the IMRT plan, the VMAT plans resulted in higher OEDs to the majority of the critical structures due to the higher volume of irradiation. This tendency is similar to the results of Lee et al. [6]. We found that the TOMO plans offered the lowest OEDs in most of the out-of-field organs, while its in-field OEDs were comparable to those of the IMRT plan. Figure 4 shows an example of the DVHs for the PTV, contralateral breast, heart, ipsilateral lung, and contralateral lung of a representative patient. These results show that the plan quality of the TOMO plans was better or comparable to that of the IMRT plans.
Figure 4

The dose-volume histograms for the

a. planning target volume, b. contralateral breast, c. heart, d. ipsilateral lung, and e. contralateral lung of one patient for the five treatment modalities.

The dose-volume histograms for the

a. planning target volume, b. contralateral breast, c. heart, d. ipsilateral lung, and e. contralateral lung of one patient for the five treatment modalities.

Comparison of lifetime attributable risk of the five treatment modalities

Table 4 shows for each modality the estimated LAR (based on calculations or measurements) to the organs of a secondary malignancy for an exposure at age between 30 and 100 years. As shown in Figure 5, LAR for each organ depends on its distance from the primary beam and the used modality. Therefore, higher LARs were obtained in the ipsilateral lung, thyroid, contralateral lung, and contralateral breast, in that order. In in-field organs, the LARs were the highest for the VMAT plans, followed by the IMRT plans. The higher LARs in the out-of-field organs for the IMRT and VMAT plans are attributed to large MUs and larger volume of irradiation [34]. The values of LAR of the TOMO plans were comparable to or lower than those of the 3D-CRT and FinF plans. For the LAR of all of the organs totaled, the TOMO plans had a value of 2083 ± 255 among 100,000 persons, which is the lowest value compared with the other modalities. The LAR of all organs for the VMAT plan was twice that of the TOMO plans. Therefore, the VMAT plans had especially high risk relative to the others.
Table 4

The lifetime attributable risk (LAR) of secondary malignancy in the organs at exposure summed to 100 years (mean ± standard deviation)

SiteLifetime attributable risk (among 100,000 population)
3D-CRTFinFIMRTVMATTOMO
Ipsilateral lung1474 ± 2701511 ± 2631408 ± 3902851 ± 5321374 ± 244
Contralateral lung129 ± 73120 ± 61134 ± 53746 ± 639154 ± 40
Contralateral breast95 ± 34104 ± 3883 ± 46355 ± 14883 ± 19
Thyroid506 ± 176496 ± 192868 ± 2801013 ± 573255 ± 55
Liver42 ± 1644 ± 1560 ± 1279 ± 3633 ± 10
Stomach100 ± 47107 ± 45146 ± 29162 ± 4055 ± 15
Colon85 ± 5194 ± 55237 ± 80181 ± 6087 ± 12
Gonad6 ± 37 ± 329 ± 1019 ± 412 ± 1
Rectum11 ± 414 ± 462 ± 2136 ± 530 ± 5
Total2448 ± 3402497 ± 3412965 ± 4935442 ± 10242083 ± 255
Figure 5

The lifetime attributable risk of secondary malignancy in each organ at risk for the five treatment modalities

a. Ipsilateral lung, contralateral lung, contralateral breast, and thyroid. b. Liver, stomach, colon, gonad, and rectum.

The lifetime attributable risk of secondary malignancy in each organ at risk for the five treatment modalities

a. Ipsilateral lung, contralateral lung, contralateral breast, and thyroid. b. Liver, stomach, colon, gonad, and rectum. An interesting finding was that the TOMO plans produced the lowest maximum and the highest mean dose (95% of the prescription dose) to the skin of the ipsilateral breast, while the IMRT plans provided the maximum skin dose (Table 5). This advantage for patients treated with TOMO can eliminate the use of a bolus to maintain good dose coverage while minimizing adverse effects on skin.
Table 5

Skin doses (Gy) of five treatment modalities

3D-CRTFinFIMRTVMATTOMO
Minimum Dose18.5 ± 6.419.6 ± 4.411.1 ± 3.911.3 ± 2.823.6 ± 7.7
Maximum Dose56.3 ± 1.355.0 ± 1.057.2 ± 1.154.6 ± 1.553.4 ± 1.1
Mean Dose43.7 ± 1.943.2 ± 1.441.6 ± 2.439.4 ± 2.347.9 ± 1.1
Some studies have reported that uncertainty in out-of-field dose calculation by treatment planning systems is approximately 50% where the region of isodose is less than 10% of the prescription dose [35, 36]. Therefore, the dose uncertainty in DVHs of the out-of-field organs might not be small. In our measurements, standard deviations in dose to the small organs such as thyroid and gonad, where detectors were located close to each other, were 6.2% and 4.9%, respectively. In larger organs, the uncertainty increased with larger distance between the detectors. Even though the risk of radiogenic cancer is generally proportional to the absorbed dose, there are non-negligible uncertainties in the risk model including dose-response relationship for carcinogenesis and modeling parameters. The latest report on radiation risk suggested that decisive choices among the several dose-response models are not possible based on the empirical data [32]. Therefore, there may be large inherent uncertainties in the risk estimation. An increase in LAR is attributed to the increase in leakage as a result of increased MUs from a traditional Linac. However, with the TOMO plan, the MUs are much greater than those of other modalities, yet the summed LAR was the lowest among modalities. Because while X-ray source of traditional Linac rotates around a patient continuously or at multiple static angles while the patient is lying still in a stationary couch, the TomoHDA system delivers the beam in a slice-by-slice fashion and each slice is collimated by the jaw in a moving couch, the definition of MU differs inherently for this modality. Therefore, MUs of TOMO cannot be explicitly compared to MUs of a traditional Linac. The low summed LAR of the TOMO plan is mainly the result of two to three tangential IMRT fields delivered by a narrow field (5.0 cm). Therefore, our result might be limited to whole-breast radiation therapy. However, others have reported that the TomoHDA system provides better shielding [35, 37] and sharper dose gradient due to shorter source-to-skin distance (85 cm) and the narrower field width than those of the traditional Linac. These factors might have helped to further reduce the systemic LAR.

CONCLUSIONS

This comparative study shows that even though an IMRT plan provides overall better plan quality and the lowest probability of pneumonitis, it causes the second highest total LAR, after a VMAT plan. Our results indicate that a TOMO plan provides a plan quality comparable to an IMRT plan and poses the lowest risk of LAR to in-field organs such as the ipsilateral lung, and to out-of-field organs. Therefore, TOMO can be a better treatment modality for younger patients who have a longer life expectancy.
  31 in total

1.  Dosimetric research on intensity-modulated arc radiotherapy planning for left breast cancer after breast-preservation surgery.

Authors:  Yong Yin; Jinhu Chen; Tao Sun; Changsheng Ma; Jie Lu; Tonghai Liu; Ruozheng Wang
Journal:  Med Dosim       Date:  2012-01-28       Impact factor: 1.482

2.  Accuracy of out-of-field dose calculation of tomotherapy and cyberknife treatment planning systems: a dosimetric study.

Authors:  Uwe Schneider; Roger A Hälg; Matthias Hartmann; Andreas Mack; Fabrizio Storelli; Andreas Joosten; Raphaël Möckli; Jürgen Besserer
Journal:  Z Med Phys       Date:  2013-11-28       Impact factor: 4.820

3.  Evaluation of the radiation pneumonia development risk in lung cancer cases.

Authors:  Sercan Yilmaz; Yasemin Guzle Adas; Ayse Hicsonmez; Meltem Nalca Andrieu; Serap Akyurek; Saban Cakir Gokce
Journal:  Asian Pac J Cancer Prev       Date:  2014

4.  Correlation of patient-related factors and dose-volume histogram parameters with the onset of radiation pneumonitis in patients with small cell lung cancer.

Authors:  Falk Roeder; Jochen Friedrich; Carmen Timke; Jutta Kappes; Peter Huber; Robert Krempien; Juergen Debus; Marc Bischof
Journal:  Strahlenther Onkol       Date:  2010-02-22       Impact factor: 3.621

5.  Reduction of radiation pneumonitis by V20-constraints in breast cancer.

Authors:  Ulla Blom Goldman; Berit Wennberg; Gunilla Svane; Håkan Bylund; Pehr Lind
Journal:  Radiat Oncol       Date:  2010-10-29       Impact factor: 3.481

6.  Cancer in the contralateral breast after radiotherapy for breast cancer.

Authors:  J D Boice; E B Harvey; M Blettner; M Stovall; J T Flannery
Journal:  N Engl J Med       Date:  1992-03-19       Impact factor: 91.245

Review 7.  Radiation-induced second cancers: the impact of 3D-CRT and IMRT.

Authors:  Eric J Hall; Cheng-Shie Wuu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

Review 8.  Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10,801 women in 17 randomised trials.

Authors:  S Darby; P McGale; C Correa; C Taylor; R Arriagada; M Clarke; D Cutter; C Davies; M Ewertz; J Godwin; R Gray; L Pierce; T Whelan; Y Wang; R Peto
Journal:  Lancet       Date:  2011-10-19       Impact factor: 79.321

9.  RapidArc, SmartArc and TomoHD compared with classical step and shoot and sliding window intensity modulated radiotherapy in an oropharyngeal cancer treatment plan comparison.

Authors:  Dirk Van Gestel; Corine van Vliet-Vroegindeweij; Frank Van den Heuvel; Wouter Crijns; Ann Coelmont; Bie De Ost; Andrea Holt; Emmy Lamers; Yasmyne Geussens; Sandra Nuyts; Danielle Van den Weyngaert; Tim Van den Wyngaert; Jan B Vermorken; Vincent Gregoire
Journal:  Radiat Oncol       Date:  2013-02-20       Impact factor: 3.481

10.  Out-of-field dosimetry measurements for a helical tomotherapy system.

Authors:  Chester Ramsey; Rebecca Seibert; Stephen L Mahan; Dharmin Desai; Daniel Chase
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

View more
  14 in total

1.  Left-sided breast cancer and risks of secondary lung cancer and ischemic heart disease : Effects of modern radiotherapy techniques.

Authors:  Stefanie Corradini; Hendrik Ballhausen; Helmut Weingandt; Philipp Freislederer; Stephan Schönecker; Maximilian Niyazi; Cristoforo Simonetto; Markus Eidemüller; Ute Ganswindt; Claus Belka
Journal:  Strahlenther Onkol       Date:  2017-09-15       Impact factor: 3.621

2.  Comparison of conventional and advanced radiotherapy techniques for left-sided breast cancer after breast conserving surgery.

Authors:  Yibo Xie; Daniel Bourgeois; Beibei Guo; Rui Zhang
Journal:  Med Dosim       Date:  2020-07-07       Impact factor: 1.482

3.  Dosimetric comparison of incidental axillary irradiation between three-dimensional conformal and volumetric modulated arc techniques for breast cancer.

Authors:  In Young Jo; Eun Seog Kim; Woo Chul Kim; Chul Kee Min; Seung-Gu Yeo
Journal:  Mol Clin Oncol       Date:  2020-03-30

4.  Three-dimensional conformal radiotherapy (3D-CRT) vs. volumetric modulated arc therapy (VMAT) in deep inspiration breath-hold (DIBH) technique in left-sided breast cancer patients-comparative analysis of dose distribution and estimation of projected secondary cancer risk.

Authors:  Iga Racka; Karolina Majewska; Janusz Winiecki
Journal:  Strahlenther Onkol       Date:  2022-08-09       Impact factor: 4.033

5.  Secondary cancer risk after whole-breast radiation therapy: field-in-field versus intensity modulated radiation therapy versus volumetric modulated arc therapy.

Authors:  Emel Haciislamoglu; Yunus Cinar; Fatih Gurcan; Emine Canyilmaz; Gorkem Gungor; Adnan Yoney
Journal:  Br J Radiol       Date:  2019-07-22       Impact factor: 3.039

Review 6.  Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer.

Authors:  Luca Cozzi; Frank Lohr; Antonella Fogliata; Davide Franceschini; Fiorenza De Rose; A R Filippi; Gabriele Guidi; Valentina Vanoni; Marta Scorsetti
Journal:  Radiat Oncol       Date:  2017-12-19       Impact factor: 3.481

7.  Accelerated whole breast irradiation in early breast cancer patients with adverse prognostic features.

Authors:  Sea-Won Lee; Kyung Hwan Shin; Eui Kyu Chie; Jin Ho Kim; Seock-Ah Im; Wonshik Han; Dong-Young Noh; Hyeon Woo Lim; Tae Hyun Kim; Keun Seok Lee; Eun Sook Lee; Soo Yoon Sung; Kyubo Kim
Journal:  Oncotarget       Date:  2016-12-06

8.  Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes.

Authors:  Mikel Byrne; Ben Archibald-Heeren; Yunfei Hu; Andrew Fong; Leena Chong; Amy Teh
Journal:  J Appl Clin Med Phys       Date:  2018-08-19       Impact factor: 2.102

9.  Exposure of remote organs and associated cancer risks from tangential and multi-field breast cancer radiotherapy.

Authors:  C Simonetto; H Rennau; J Remmele; S Sebb; P Kundrát; M Eidemüller; U Wolf; G Hildebrandt
Journal:  Strahlenther Onkol       Date:  2018-10-22       Impact factor: 3.621

10.  Estimation of the Thyroid Secondary Cancer Risk on the Patient of Standard Breast External Beam Radiotherapy.

Authors:  Zeinab Momeni; Mohammad Bagher Tavakoli; Maryam Atarod
Journal:  J Med Signals Sens       Date:  2018 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.