Literature DB >> 11143252

A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.

I Paddick1.   

Abstract

A conformity index is a measure of how well the volume of a radiosurgical dose distribution conforms to the size and shape of a target volume. Because the success of radiosurgery is related to the extremely conformal irradiation of the target, an accurate method for describing this parameter is important. Existing conformity ratios and indices used in radiosurgery are reviewed and criticized. It will be demonstrated that previously proposed measurements of conformity can, under certain conditions, give false perfect scores. A new conformity index is derived that gives an objective score of conformity for a treatment plan and gives no false scores. An analysis of five different treatment plans is made using both the existing scoring methods and the new conformity index.

Mesh:

Year:  2000        PMID: 11143252     DOI: 10.3171/jns.2000.93.supplement

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  316 in total

1.  Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Hui-Min Ting; Su-Hua Lo; Yu-Wen Wang; Chiu-Ching Tuan; Fu-Min Fang; Te-Jen Su
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

2.  Effect of photon-beam energy on VMAT and IMRT treatment plan quality and dosimetric accuracy for advanced prostate cancer.

Authors:  Marlies Pasler; Dietmar Georg; Holger Wirtz; Johannes Lutterbach
Journal:  Strahlenther Onkol       Date:  2011-11-29       Impact factor: 3.621

3.  A novel correction factor based on extended volume to complement the conformity index.

Authors:  F Jin; Y Wang; Y-Z Wu
Journal:  Br J Radiol       Date:  2011-11-29       Impact factor: 3.039

4.  Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery.

Authors:  J A Tanyi; C M Kato; Y Chen; Z Chen; M Fuss
Journal:  Br J Radiol       Date:  2010-10-05       Impact factor: 3.039

5.  Improving IMRT delivery efficiency with reweighted L1-minimization for inverse planning.

Authors:  Hojin Kim; Stephen Becker; Rena Lee; Soonhyouk Lee; Sukyoung Shin; Emmanuel Candès; Lei Xing; Ruijiang Li
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

6.  Automated intensity modulated treatment planning: The expedited constrained hierarchical optimization (ECHO) system.

Authors:  Masoud Zarepisheh; Linda Hong; Ying Zhou; Jung Hun Oh; James G Mechalakos; Margie A Hunt; Gig S Mageras; Joseph O Deasy
Journal:  Med Phys       Date:  2019-05-29       Impact factor: 4.071

7.  Planning benchmark study for SBRT of early stage NSCLC : Results of the DEGRO Working Group Stereotactic Radiotherapy.

Authors:  Christos Moustakis; Oliver Blanck; Fatemeh Ebrahimi Tazehmahalleh; Mark Ka Heng Chan; Iris Ernst; Thomas Krieger; Marciana-Nona Duma; Markus Oechsner; Ute Ganswindt; Christian Heinz; Horst Alheit; Hilbert Blank; Ursula Nestle; Rolf Wiehle; Christine Kornhuber; Christian Ostheimer; Cordula Petersen; Gerhard Pollul; Wolfgang Baus; Georg Altenstein; Eric Beckers; Katrin Jurianz; Florian Sterzing; Matthias Kretschmer; Heinrich Seegenschmiedt; Torsten Maass; Stefan Droege; Ulrich Wolf; Juergen Schoeffler; Uwe Haverkamp; Hans Theodor Eich; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2017-05-31       Impact factor: 3.621

8.  Comparative analysis between 5 mm and 7.5 mm collimators in CyberKnife radiosurgery for trigeminal neuralgia.

Authors:  H Sudahar; P G G Kurup; V Murali; J Velmurugan
Journal:  J Med Phys       Date:  2013-07

9.  Hybrid volumetric modulated arc therapy for whole breast irradiation: a dosimetric comparison of different arc designs.

Authors:  Velayudham Ramasubramanian; Karunakaran Balaji; Sitaraman Balaji Subramanian; Krishnamoorthi Sathiya; Moorthi Thirunavukarasu; Chandrasekaran Anu Radha
Journal:  Radiol Med       Date:  2019-01-30       Impact factor: 3.469

10.  Node-positive left-sided breast cancer: does VMAT improve treatment plan quality with respect to IMRT?

Authors:  M Pasler; D Georg; S Bartelt; J Lutterbach
Journal:  Strahlenther Onkol       Date:  2013-03-24       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.