Literature DB >> 16414369

Conformity index: a review.

Loïc Feuvret1, Georges Noël, Jean-Jacques Mazeron, Pierre Bey.   

Abstract

We present a critical analysis of the conformity indices described in the literature and an evaluation of their field of application. Three-dimensional conformal radiotherapy, with or without intensity modulation, is based on medical imaging techniques, three-dimensional dosimetry software, compression accessories, and verification procedures. It consists of delineating target volumes and critical healthy tissues to select the best combination of beams. This approach allows better adaptation of the isodose to the tumor volume, while limiting irradiation of healthy tissues. Tools must be developed to evaluate the quality of proposed treatment plans. Dosimetry software provides the dose distribution in each CT section and dose-volume histograms without really indicating the degree of conformity. The conformity index is a complementary tool that attributes a score to a treatment plan or that can compare several treatment plans for the same patient. The future of conformal index in everyday practice therefore remains unclear.

Entities:  

Mesh:

Year:  2006        PMID: 16414369     DOI: 10.1016/j.ijrobp.2005.09.028

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  270 in total

1.  [The ICRU Report 83: prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)].

Authors:  N Hodapp
Journal:  Strahlenther Onkol       Date:  2012-01       Impact factor: 3.621

2.  Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation.

Authors:  Cem Onal; Aydan Sonmez; Gungor Arslan; Ezgi Oymak; Ayse Kotek; Esma Efe; Serhat Sonmez; Yemliha Dolek
Journal:  Jpn J Radiol       Date:  2011-12-21       Impact factor: 2.374

3.  A novel correction factor based on extended volume to complement the conformity index.

Authors:  F Jin; Y Wang; Y-Z Wu
Journal:  Br J Radiol       Date:  2011-11-29       Impact factor: 3.039

4.  Dosimetric and radiobiological comparison of helical tomotherapy, forward-planned intensity-modulated radiotherapy and two-phase conformal plans for radical radiotherapy treatment of head and neck squamous cell carcinomas.

Authors:  S Chatterjee; N Willis; S M Locks; J H Mott; C G Kelly
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

5.  Reduction of dosimetric impact of intrafractional prostate motion during helical tomotherapy.

Authors:  V Prokic; H Geinitz; P Kneschaurek
Journal:  Strahlenther Onkol       Date:  2012-02-16       Impact factor: 3.621

6.  Dosimetric comparison of 2.5 mm vs. 3.0 mm leaf width micro-multileaf collimator-based treatment systems for intracranial stereotactic radiosurgery using dynamic conformal arcs: implications for treatment planning.

Authors:  Kazuhiro Ohtakara; Shinya Hayashi; Hidekazu Tanaka; Hiroaki Hoshi
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

7.  Quality assessment of interstitial implants in high- dose- rate brachytherapy after lumpectomy in patients of early stage breast cancer.

Authors:  Samrat Dutta; Suresh C Sharma; Rajinder Singh; Rakesh Kapoor; Arun S Oinam; Anoop Bhardwaj; Pradeep Goswami
Journal:  Indian J Surg Oncol       Date:  2011-03-24

8.  Human-computer interaction in radiotherapy target volume delineation: a prospective, multi-institutional comparison of user input devices.

Authors: 
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

9.  Definitive-intent intensity-modulated radiation therapy provides similar outcomes to those previously published for definitive-intent three-dimensional conformal radiation therapy in dogs with primary brain tumors: A multi-institutional retrospective study.

Authors:  Nathaniel Van Asselt; Neil Christensen; Valeria Meier; Carla Rohrer Bley; Sarah Laliberte; Valerie J Poirier; Noopur Desai; Yi Chen; Michelle Turek
Journal:  Vet Radiol Ultrasound       Date:  2020-05-01       Impact factor: 1.363

10.  Stereotactic radiosurgery for non-vestibular cranial nerve schwanommas.

Authors:  Myreille D'Astous; Allen L Ho; Arjun Pendharkar; Clara Y H Choi; Scott G Soltys; Iris C Gibbs; Armine T Tayag; Patricia A Thompson; John R Adler; Steven D Chang
Journal:  J Neurooncol       Date:  2016-10-17       Impact factor: 4.130

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.