Literature DB >> 2694959

Comparison of membrane filtration and Autoanalysis Colilert presence-absence techniques for analysis of total coliforms and Escherichia coli in drinking water samples.

C M Lewis1, J L Mak.   

Abstract

Over a 4-month period, 950 samples of treated drinking water were analyzed for total coliforms (TC) and Escherichia coli by both membrane filtration (MF) and Autoanalysis Colilert presence-absence (AC) techniques. The two tests agreed 97% of the time on the basis of presumptive TC results and 98.5% of the time on the basis of verified TC results. Samples which produced disagreement between the two tests were most often TC positive by MF and TC negative by AC. E. coli was recovered four times: twice by MF only, and twice by AC only but without the diagnostic fluorescence reaction. In two samples, E. coli could not be isolated from fluorescence-positive AC tests. On the basis of these results, the AC test was implemented as the routine analytical procedure for TC but not for E. coli.

Entities:  

Mesh:

Year:  1989        PMID: 2694959      PMCID: PMC203228          DOI: 10.1128/aem.55.12.3091-3094.1989

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  5 in total

1.  Membrane filter staining method: bacterial plate counts in 24 H.

Authors:  K M Tse; C M Lewis
Journal:  Appl Environ Microbiol       Date:  1984-08       Impact factor: 4.792

2.  Frequency distribution of coliforms in water distribution systems.

Authors:  R R Christian; W O Pipes
Journal:  Appl Environ Microbiol       Date:  1983-02       Impact factor: 4.792

3.  National field evaluation of a defined substrate method for the simultaneous enumeration of total coliforms and Escherichia coli from drinking water: comparison with the standard multiple tube fermentation method.

Authors:  S C Edberg; M J Allen; D B Smith
Journal:  Appl Environ Microbiol       Date:  1988-06       Impact factor: 4.792

4.  Thermotolerant non-fecal source Klebsiella pneumoniae: validity of the fecal coliform test in recreational waters.

Authors:  N R Caplenas; M S Kanarek
Journal:  Am J Public Health       Date:  1984-11       Impact factor: 9.308

5.  Proportion of beta-D-glucuronidase-negative Escherichia coli in human fecal samples.

Authors:  G W Chang; J Brill; R Lum
Journal:  Appl Environ Microbiol       Date:  1989-02       Impact factor: 4.792

  5 in total
  8 in total

1.  Polymerase chain reaction-gene probe detection of microorganisms by using filter-concentrated samples.

Authors:  A K Bej; M H Mahbubani; J L Dicesare; R M Atlas
Journal:  Appl Environ Microbiol       Date:  1991-12       Impact factor: 4.792

2.  Total coliform detection in drinking water: comparison of membrane filtration with Colilert and Coliquik.

Authors:  B H Olson; D L Clark; B B Milner; M H Stewart; R L Wolfe
Journal:  Appl Environ Microbiol       Date:  1991-05       Impact factor: 4.792

3.  Field evaluation of two colorimetric coliphage detection methods.

Authors:  M M Ijzerman; J O Falkinham; R B Reneau; C Hagedorn
Journal:  Appl Environ Microbiol       Date:  1994-03       Impact factor: 4.792

4.  Marine bacteria cause false-positive results in the Colilert-18 rapid identification test for Escherichia coli in Florida waters.

Authors:  John M Pisciotta; Damon F Rath; Paul A Stanek; D Michael Flanery; Valerie J Harwood
Journal:  Appl Environ Microbiol       Date:  2002-02       Impact factor: 4.792

5.  Evaluation of test media for routine monitoring of Escherichia coli in nonpotable waters.

Authors:  I D Gaudet; L Z Florence; R N Coleman
Journal:  Appl Environ Microbiol       Date:  1996-11       Impact factor: 4.792

6.  Evaluation of commercial presence-absence test kits for detection of total coliforms, Escherichia coli, and other indicator bacteria.

Authors:  J A Clark; A H el-Shaarawi
Journal:  Appl Environ Microbiol       Date:  1993-02       Impact factor: 4.792

7.  Detection of coliform bacteria and Escherichia coli by multiplex polymerase chain reaction: comparison with defined substrate and plating methods for water quality monitoring.

Authors:  A K Bej; S C McCarty; R M Atlas
Journal:  Appl Environ Microbiol       Date:  1991-08       Impact factor: 4.792

8.  Comparative study of commercial 4-methylumbelliferyl-beta-D-glucuronide preparations with the Standard Methods membrane filtration fecal coliform test for the detection of Escherichia coli in water samples.

Authors:  D L Clark; B B Milner; M H Stewart; R L Wolfe; B H Olson
Journal:  Appl Environ Microbiol       Date:  1991-05       Impact factor: 4.792

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.