Literature DB >> 26936707

A Bayesian spatial temporal mixtures approach to kinetic parametric images in dynamic positron emission tomography.

W Zhu1, J Ouyang2, Y Rakvongthai3, N J Guehl2, D W Wooten2, G El Fakhri2, M D Normandin2, Y Fan1.   

Abstract

PURPOSE: Estimation of parametric maps is challenging for kinetic models in dynamic positron emission tomography. Since voxel kinetics tend to be spatially contiguous, the authors consider groups of homogeneous voxels together. The authors propose a novel algorithm to identify the groups and estimate kinetic parameters simultaneously. Uncertainty estimates for kinetic parameters are also obtained.
METHODS: Mixture models were used to fit the time activity curves. In order to borrow information from spatially nearby voxels, the Potts model was adopted. A spatial temporal model was built incorporating both spatial and temporal information in the data. Markov chain Monte Carlo was used to carry out parameter estimation. Evaluation and comparisons with existing methods were carried out on cardiac studies using both simulated data sets and a pig study data. One-compartment kinetic modeling was used, in which K1 is the parameter of interest, providing a measure of local perfusion.
RESULTS: Based on simulation experiments, the median standard deviation across all image voxels, of K1 estimates were 0, 0.13, and 0.16 for the proposed spatial mixture models (SMMs), standard curve fitting, and spatial K-means methods, respectively. The corresponding median mean squared biases for K1 were 0.04, 0.06, and 0.06 for abnormal region of interest (ROI); 0.03, 0.03, and 0.04 for normal ROI; and 0.007, 0.02, and 0.05 for the noise region.
CONCLUSIONS: SMM is a fully Bayesian algorithm which determines the optimal number of homogeneous voxel groups, voxel group membership, parameter estimation, and parameter uncertainty estimation simultaneously. The voxel membership can also be used for classification purposes. By borrowing information from spatially nearby voxels, SMM substantially reduces the variability of parameter estimates. In some ROIs, SMM also reduces mean squared bias.

Entities:  

Mesh:

Year:  2016        PMID: 26936707      PMCID: PMC5025019          DOI: 10.1118/1.4941010

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

2.  Simultaneous segmentation, kinetic parameter estimation, and uncertainty visualization of dynamic PET images.

Authors:  Ahmed Saad; Ben Smith; Ghassan Hamarneh; Torsten Möller
Journal:  Med Image Comput Comput Assist Interv       Date:  2007

3.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  Single-scan rest∕stress imaging (18)F-labeled flow tracers.

Authors:  Nathaniel Alpert; Yu-Hua Dean Fang; Georges El Fakhri
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

5.  Efficient Classification-Based Relabeling in Mixture Models.

Authors:  Andrew J Cron; Mike West
Journal:  Am Stat       Date:  2011-02-01       Impact factor: 8.710

6.  Use of ridge regression for improved estimation of kinetic constants from PET data.

Authors:  F O'Sullivan; A Saha
Journal:  IEEE Trans Med Imaging       Date:  1999-02       Impact factor: 10.048

7.  Sparsity Constrained Mixture Modeling for the Estimation of Kinetic Parameters in Dynamic PET.

Authors:  Yanguang Lin; Justin P Haldar; Quanzheng Li; Peter S Conti; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2013-11-07       Impact factor: 10.048

8.  Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study.

Authors:  Y Petibon; J Ouyang; X Zhu; C Huang; T G Reese; S Y Chun; Q Li; G El Fakhri
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

9.  Compartmental modeling of 11C-HOMADAM binding to the serotonin transporter in the healthy human brain.

Authors:  Jonathon A Nye; John R Votaw; Nachwa Jarkas; David Purselle; Vernon Camp; James D Bremner; Clinton D Kilts; Charles B Nemeroff; Mark M Goodman
Journal:  J Nucl Med       Date:  2008-12       Impact factor: 10.057

10.  COMT genotype predicts cortical-limbic D1 receptor availability measured with [11C]NNC112 and PET.

Authors:  M Slifstein; B Kolachana; E H Simpson; P Tabares; B Cheng; M Duvall; W Gordon Frankle; D R Weinberger; M Laruelle; A Abi-Dargham
Journal:  Mol Psychiatry       Date:  2008-03-04       Impact factor: 15.992

View more
  2 in total

1.  Efficient DCE-MRI Parameter and Uncertainty Estimation Using a Neural Network.

Authors:  Yannick Bliesener; Jay Acharya; Krishna S Nayak
Journal:  IEEE Trans Med Imaging       Date:  2019-11-26       Impact factor: 10.048

Review 2.  Spatial and spatio-temporal statistical analyses of retinal images: a review of methods and applications.

Authors:  Wenyue Zhu; Ruwanthi Kolamunnage-Dona; Yalin Zheng; Simon Harding; Gabriela Czanner
Journal:  BMJ Open Ophthalmol       Date:  2020-05-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.