Literature DB >> 24216681

Sparsity Constrained Mixture Modeling for the Estimation of Kinetic Parameters in Dynamic PET.

Yanguang Lin, Justin P Haldar, Quanzheng Li, Peter S Conti, Richard M Leahy.   

Abstract

The estimation and analysis of kinetic parameters in dynamic positron emission tomography (PET) is frequently confounded by tissue heterogeneity and partial volume effects. We propose a new constrained model of dynamic PET to address these limitations. The proposed formulation incorporates an explicit mixture model in which each image voxel is represented as a mixture of different pure tissue types with distinct temporal dynamics. We use Cramér-Rao lower bounds to demonstrate that the use of prior information is important to stabilize parameter estimation with this model. As a result, we propose a constrained formulation of the estimation problem that we solve using a two-stage algorithm. In the first stage, a sparse signal processing method is applied to estimate the rate parameters for the different tissue compartments from the noisy PET time series. In the second stage, tissue fractions and the linear parameters of different time activity curves are estimated using a combination of spatial-regularity and fractional mixture constraints. A block coordinate descent algorithm is combined with a manifold search to robustly estimate these parameters. The method is evaluated with both simulated and experimental dynamic PET data.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24216681      PMCID: PMC4013253          DOI: 10.1109/TMI.2013.2283229

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  Resolution and noise properties of MAP reconstruction for fully 3-D PET.

Authors:  J Qi; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

Authors:  Jing Tang; Hiroto Kuwabara; Dean F Wong; Arman Rahmim
Journal:  Phys Med Biol       Date:  2010-07-20       Impact factor: 3.609

3.  Imaging radiotracer model parameters in PET: a mixture analysis approach.

Authors:  F O'Sullivan
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

4.  Dynamic positron emission tomography data-driven analysis using sparse Bayesian learning.

Authors:  Jyh-Ying Peng; John A D Aston; Roger N Gunn; Cheng-Yuan Liou; John Ashburner
Journal:  IEEE Trans Med Imaging       Date:  2008-09       Impact factor: 10.048

Review 5.  Tumor progression and metastasis.

Authors:  J Yokota
Journal:  Carcinogenesis       Date:  2000-03       Impact factor: 4.944

6.  Use of ridge regression for improved estimation of kinetic constants from PET data.

Authors:  F O'Sullivan; A Saha
Journal:  IEEE Trans Med Imaging       Date:  1999-02       Impact factor: 10.048

7.  Dynamic PET 18F-FDG studies in patients with primary and recurrent soft-tissue sarcomas: impact on diagnosis and correlation with grading.

Authors:  A Dimitrakopoulou-Strauss; L G Strauss; M Schwarzbach; C Burger; T Heichel; F Willeke; G Mechtersheimer; T Lehnert
Journal:  J Nucl Med       Date:  2001-05       Impact factor: 10.057

8.  Spatial heterogeneity in sarcoma 18F-FDG uptake as a predictor of patient outcome.

Authors:  Janet F Eary; Finbarr O'Sullivan; Janet O'Sullivan; Ernest U Conrad
Journal:  J Nucl Med       Date:  2008-11-07       Impact factor: 10.057

9.  Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography.

Authors:  D Feng; S C Huang; X Wang
Journal:  Int J Biomed Comput       Date:  1993-03

10.  COMT genotype predicts cortical-limbic D1 receptor availability measured with [11C]NNC112 and PET.

Authors:  M Slifstein; B Kolachana; E H Simpson; P Tabares; B Cheng; M Duvall; W Gordon Frankle; D R Weinberger; M Laruelle; A Abi-Dargham
Journal:  Mol Psychiatry       Date:  2008-03-04       Impact factor: 15.992

View more
  10 in total

1.  PROBING IN VIVO MICROSTRUCTURE WITH T 1-T 2 RELAXATION CORRELATION SPECTROSCOPIC IMAGING.

Authors:  Daeun Kim; Jessica L Wisnowski; Christopher T Nguyen; Justin P Haldar
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2018-05-24

2.  Functional Data Analysis of Dynamic PET Data.

Authors:  Yakuan Chen; Jeff Goldsmith; R Todd Ogden
Journal:  J Am Stat Assoc       Date:  2018-10-26       Impact factor: 5.033

3.  Population Pharmacokinetics of Tracers: A New Tool for Medical Imaging?

Authors:  Peggy Gandia; Cyril Jaudet; Etienne Chatelut; Didier Concordet
Journal:  Clin Pharmacokinet       Date:  2017-02       Impact factor: 6.447

4.  A Bayesian spatial temporal mixtures approach to kinetic parametric images in dynamic positron emission tomography.

Authors:  W Zhu; J Ouyang; Y Rakvongthai; N J Guehl; D W Wooten; G El Fakhri; M D Normandin; Y Fan
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

5.  Direct estimation of tracer-kinetic parameter maps from highly undersampled brain dynamic contrast enhanced MRI.

Authors:  Yi Guo; Sajan Goud Lingala; Yinghua Zhu; R Marc Lebel; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2016-11-17       Impact factor: 4.668

6.  Multidimensional correlation spectroscopic imaging of exponential decays: From theoretical principles to in vivo human applications.

Authors:  Daeun Kim; Jessica L Wisnowski; Christopher T Nguyen; Justin P Haldar
Journal:  NMR Biomed       Date:  2020-01-07       Impact factor: 4.044

Review 7.  Combined diffusion-relaxometry microstructure imaging: Current status and future prospects.

Authors:  Paddy J Slator; Marco Palombo; Karla L Miller; Carl-Fredrik Westin; Frederik Laun; Daeun Kim; Justin P Haldar; Dan Benjamini; Gregory Lemberskiy; Joao P de Almeida Martins; Jana Hutter
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 3.737

8.  Joint arterial input function and tracer kinetic parameter estimation from undersampled dynamic contrast-enhanced MRI using a model consistency constraint.

Authors:  Yi Guo; Sajan Goud Lingala; Yannick Bliesener; R Marc Lebel; Yinghua Zhu; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

9.  Greedy Algorithms for Nonnegativity-Constrained Simultaneous Sparse Recovery.

Authors:  Daeun Kim; Justin P Haldar
Journal:  Signal Processing       Date:  2016-02-06       Impact factor: 4.662

10.  Diffusion-relaxation correlation spectroscopic imaging: A multidimensional approach for probing microstructure.

Authors:  Daeun Kim; Eamon K Doyle; Jessica L Wisnowski; Joong Hee Kim; Justin P Haldar
Journal:  Magn Reson Med       Date:  2017-03-19       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.